Hp 8.20q Fibre Channel Switch Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Stockage Hp 8.20q Fibre Channel Switch. HP 8.20q Fibre Channel Switch User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 114
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
HP SN6000 Fibre Channel Switch QuickTools
Switch Management User Guide
This user guide describes the QuickTools web applet (version 8.00.4) for the HP SN6000 Fibre Channel Switch (firmware
version 8.0.4). The QuickTools web applet is a graphical user interface that provides tools for fabric, switch, and port
management tasks. This user guide is intended for users responsible for installing and using switch management tools.
Part Number: 5697-1315
Published January 2012
Edition: 3
Vue de la page 0
1 2 3 4 5 6 ... 113 114

Résumé du contenu

Page 1 - Switch Management User Guide

HP SN6000 Fibre Channel Switch QuickTools Switch Management User GuideThis user guide describes the QuickTools web applet (version 8.00.4) for the HP

Page 2

10Opening QuickToolsOnce the switch is operational, open the QuickTools web applet.To open the QuickTools web applet:1. In an Internet browser, enter

Page 3 - Contents

100Port typesTo display the port type status, open the View menu and select View Port Types. Table 23 lists the possible port types and their descript

Page 4

HP SN6000 Fibre Channel Switch QuickTools Switch Management User Guide 101Port transceiver media statusTo display the transceiver media status, open t

Page 5

102I/O Stream GuardThe I/O Stream Guard feature suppresses the Registered State Change Notification (RSCN) messages on a port basis. I/O Stream Guard

Page 6

HP SN6000 Fibre Channel Switch QuickTools Switch Management User Guide 103Testing portsYou can test a port using the Port Diagnostics dialog box. Only

Page 7

1046. Select a Loop Count option: The Loop Forever option runs the test until you click Stop Test. The Loop Count option runs the test a specific numb

Page 8

HP SN6000 Fibre Channel Switch QuickTools Switch Management User Guide 1055 Support and Other ResourcesDocument conventions and symbolsWARNING! Indica

Page 9 - 1 Using QuickTools

1063. The name "JDOM" must not be used to endorse or promote products derived from this software without prior written permission. For writt

Page 10 - Opening QuickTools

HP SN6000 Fibre Channel Switch QuickTools Switch Management User Guide 107Related informationDocumentsIn addition to this guide, see the following doc

Page 12 - Data windows and tabs

HP SN6000 Fibre Channel Switch QuickTools Switch Management User Guide 109GlossaryActive zone set The zone set that defines the current zoning for the

Page 13 - Alerts panel

HP SN6000 Fibre Channel Switch QuickTools Switch Management User Guide 11QuickTools user interfaceThe QuickTools web applet uses faceplate and backpla

Page 14 - Menu bar

110Fabric name User-defined name associated with the file that contains user list data for the fabric.Fabric port An F_PortFabric view file A file con

Page 15

HP SN6000 Fibre Channel Switch QuickTools Switch Management User Guide 111Maintenance mode Formerly known as force PROM mode. Sets the IP address to 1

Page 16 - Selecting ports

112Target A storage device that responds to an initiator device.TR Transparent RouterTR Port Transparent Router port. The port type used to map device

Page 17

HP SN6000 Fibre Channel Switch QuickTools Switch Management User Guide 113IndexNumerics20Gb ISL license key 78AActive Zoneset data window 33Add TR Map

Page 18 - Exiting QuickTools

114opening window 10operating systems 9orphan zone set 35Ppaging a switch 58popup menus 16port activation license key 78port administrative states 99P

Page 19 - 2 Managing Fabrics

12Fabric treeThe QuickTools web applet enables you to manage the switches in one fabric. The fabric tree (Figure 3) provides access to each switch fac

Page 20 - Transparent router

HP SN6000 Fibre Channel Switch QuickTools Switch Management User Guide 13Alerts panelThe Alerts panel shows all reasons for status, including faults.

Page 21

14Menu barThe QuickTools web applet menu bar options are described in Table 2.Table 2 Menu bar options Option Sub-optionsFile PreferencesFabric Nickna

Page 22 - TR Mapping Manager dialog

HP SN6000 Fibre Channel Switch QuickTools Switch Management User Guide 15Stack These options are available only if the stack icon or name is selected

Page 23 - Add TR Mapping dialog

16Popup menusPopup menus appear when you right-click the switch faceplate or backplate images in the graphic window. Popup menu options give you quick

Page 24 - Remote Fabric Zoning dialog

HP SN6000 Fibre Channel Switch QuickTools Switch Management User Guide 17Setting QuickTools preferencesUsing the preferences settings, you can:• Chang

Page 25

18Using online helpThe browser-based online Help system can be accessed from the QuickTools web applet several ways. Online Help is also context-sensi

Page 26

HP SN6000 Fibre Channel Switch QuickTools Switch Management User Guide 192 Managing FabricsThis chapter describes the options for managing fabrics.Fab

Page 27 - Event Browser

Legal and notice information© Copyright 2010-2012 Hewlett-Packard Development Company, L.P.© Copyright 2010–2012 This software includes technology und

Page 28

20If you are adding a new switch to a fabric and do not want to accept the default fabric configuration:1. If the switch is not new from the factory,

Page 29 - Sorting the Event Browser

HP SN6000 Fibre Channel Switch QuickTools Switch Management User Guide 21The local fabric may consist of one or multiple HP SN6000 Fibre Channel Switc

Page 30 - Devices data window

22IMPORTANT: Since C-series switches do not support the Unzoned Name Server, C-series fabrics must be “pre-zoned” before you can set up TR mappings to

Page 31

HP SN6000 Fibre Channel Switch QuickTools Switch Management User Guide 23Removing an inter-fabric routeTo remove an inter-fabric route:1. Open the fac

Page 32 - Deleting a nickname

245. Select a TR port from the 3 Select a TR Port column.After selecting an option from the 3 Select a TR Port column, the OK button becomes active.6.

Page 33 - Active Zoneset data window

HP SN6000 Fibre Channel Switch QuickTools Switch Management User Guide 255. In the Remote Fabric Zoning dialog (Figure 9), if you made and saved chang

Page 34 - Zoning concepts

26Transparent Routes data windowThe Transparent Routes data window displays the currently configured inter-fabric zones/routes using a TR_Port. Figure

Page 35 - Zoning database

HP SN6000 Fibre Channel Switch QuickTools Switch Management User Guide 27The Transparent Route dialog (Figure 11) displays detailed information about

Page 36 - Managing the zoning database

28To display the Event Browser, open the Fabric menu and select Show Event Browser. If the Show Event Browser selection is grayed-out, you must first

Page 37 - Editing the zoning database

HP SN6000 Fibre Channel Switch QuickTools Switch Management User Guide 29Filtering the Event BrowserFiltering the Event Browser enables you to display

Page 38

HP SN6000 Fibre Channel Switch QuickTools Switch Management User Guide 31 Using QuickTools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 39 - Options for resolving zoning

30Device information and nicknamesDevices are hosts and storage targets connected to the switch. A nickname is a user-definable, meaningful name that

Page 40 - Discard Inactive

HP SN6000 Fibre Channel Switch QuickTools Switch Management User Guide 31The Devices data window fields are described in Table 5.Displaying detailed d

Page 41 - Managing zone sets

32Managing device port nicknamesYou can assign a nickname to a device port World Wide Name. A nickname is a user-definable, meaningful name that can b

Page 42 - Managing zones

HP SN6000 Fibre Channel Switch QuickTools Switch Management User Guide 33Exporting nicknames to a fileYou can save nicknames to a file. This is useful

Page 43 - Adding zone members

34Configured Zonesets data windowThe Configured Zonesets data window (Figure 17) displays all zone sets, zones, aliases, and zone membership in the zo

Page 44 - Removing a zone member

HP SN6000 Fibre Channel Switch QuickTools Switch Management User Guide 35A zone can be a component of more than one zone set. Several zone sets can be

Page 45 - Managing aliases

36Viewing zoning limits and propertiesZoning limits vary depending on the firmware installed on the switch:• MaxZoneSets—The maximum number of zone se

Page 46 - Zone merge failure recovery

HP SN6000 Fibre Channel Switch QuickTools Switch Management User Guide 37Editing the zoning databaseUse the Edit Zoning dialog box (Figure 18) to edit

Page 47 - 3 Managing Switches

38Using tool bar buttons, popup menus, or the drag-and-drop method, you can create and manage zone sets and zones in the zoning database. Table 6 desc

Page 48

HP SN6000 Fibre Channel Switch QuickTools Switch Management User Guide 39Options for resolving zoningThe Resolving Zoning options enable you to manage

Page 49

4Managing the zoning database. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36Editing the zoning databa

Page 50

40NOTE: Disabling the Merge Auto Save parameter can be useful to prevent the propagation of zoning information when experimenting with different zonin

Page 51

HP SN6000 Fibre Channel Switch QuickTools Switch Management User Guide 41Removing all zone and zone set definitionsTo remove all zone and zone set def

Page 52 - Stack Links data window

42Renaming a zone setTo rename a zone set:1. In the Zone Sets tree of the Edit Zoning dialog box, click the zone set to be renamed.2. Open the Edit me

Page 53 - Managing switch stacks

HP SN6000 Fibre Channel Switch QuickTools Switch Management User Guide 43Copying a zone to a zone setTo copy an existing zone and its membership from

Page 54 - Managing user accounts

44Renaming a zoneTo rename a zone:1. In the Zone Sets tree of the Edit Zoning dialog box, click the zone to be renamed.2. Select Edit > Rename.3. I

Page 55 - Creating user accounts

HP SN6000 Fibre Channel Switch QuickTools Switch Management User Guide 45Managing aliasesAn alias is a collection of objects that can be zoned togethe

Page 56 - Removing a user account

46Merging fabrics and zoningIf you join two fabrics with an inter-switch link, the active zone sets from the two fabrics attempt to merge automaticall

Page 57

HP SN6000 Fibre Channel Switch QuickTools Switch Management User Guide 473 Managing SwitchesThis chapter describes the tasks that manage switches in t

Page 58 - Paging a switch

48The Switch data window fields are described in Table 8. Table 8 Switch data window fields Field DescriptionSummary GroupSwitch Type Switch modelFirs

Page 59

HP SN6000 Fibre Channel Switch QuickTools Switch Management User Guide 49POST Status The current diagnostic state of the switch.POST Fault Code The co

Page 60 - Configuring a switch

HP SN6000 Fibre Channel Switch QuickTools Switch Management User Guide 5Managing system services . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 61 - Switch properties

50Firmware GroupFirmware Version Active firmware versionInactive Firmware Version This field does not apply to this switchPending Firmware Version Fir

Page 62 - In-band management

HP SN6000 Fibre Channel Switch QuickTools Switch Management User Guide 51Zones/Security GroupInterop Mode StandardLegacy Address Format NoneMerge Auto

Page 63 - Advanced switch properties

52Stack Links data windowThe Stack Links data window displays information about all switch links for a stack of switches in the faceplate display. Thi

Page 64 - Managing system services

HP SN6000 Fibre Channel Switch QuickTools Switch Management User Guide 53Managing switch stacksThe QuickTools web applet recognizes switches as a stac

Page 65 - Network properties

54Security consistency checklistThe Security Consistency Checklist dialog box (Figure 23) enables you to view current security-related settings, such

Page 66

HP SN6000 Fibre Channel Switch QuickTools Switch Management User Guide 55Creating user accountsA switch can have a maximum of 15 user accounts. Figure

Page 67 - Network DNS configuration

56Removing a user accountTo remove a user account on a switch:1. Select Switch > User Accounts. 2. Click the Remove Account tab to open the Remove

Page 68 - SNMP configuration

HP SN6000 Fibre Channel Switch QuickTools Switch Management User Guide 57Changing a user account passwordA user can change the password for their acco

Page 69

58Modifying a user accountTo modify a user account on a switch:1. Select Switch > User Accounts.2. Click the Modify Account tab in the User Account

Page 70 - SNMP v3 Security

HP SN6000 Fibre Channel Switch QuickTools Switch Management User Guide 59Setting the date/time and enabling NTP clientThe Date/Time dialog box enables

Page 71 - Adding an SNMP v3 user

6Figures1 Add a New Fabric dialog box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102 Pas

Page 72 - Removing an SNMP v3 user

60Resetting a switchResetting a switch reboots the switch using the configuration parameters in memory. Depending on the reset type, a switch reset ma

Page 73 - Testing a switch

HP SN6000 Fibre Channel Switch QuickTools Switch Management User Guide 61Switch propertiesUse the Switch Properties dialog box to change the following

Page 74 - Archiving a switch

62SyslogThe Syslog (Remote Logging) feature enables saving the log information to a remote host that supports the syslog protocol. When enabled, the l

Page 75 - Restoring a switch

HP SN6000 Fibre Channel Switch QuickTools Switch Management User Guide 63Fabric device management interfaceFabric Device Management Interface (FDMI) p

Page 76

64Managing system servicesThe System Services dialog box (Figure 31) provides a central location for you to enable or disable any of the external user

Page 77

HP SN6000 Fibre Channel Switch QuickTools Switch Management User Guide 65Network propertiesUse the Network Properties dialog boxes (Figure 32) to conf

Page 78

66Table 11 describes the network IP configuration parameters.Table 11 Network Properties dialog box—IP fields Field DescriptionIPv4 Network Enable thi

Page 79 - Installing firmware

HP SN6000 Fibre Channel Switch QuickTools Switch Management User Guide 67Network DNS configurationThe Network Properties dialog box has two tabs: IP a

Page 80

68SNMP configurationThe Simple Network Management Protocol configuration includes properties and trap parameters plus SNMP v3 manager and user paramet

Page 81 - Using Call Home

HP SN6000 Fibre Channel Switch QuickTools Switch Management User Guide 69Table 13 describes the SNMP Properties dialog box fields.Table 13 SNMP Proper

Page 82

HP SN6000 Fibre Channel Switch QuickTools Switch Management User Guide 7Tables1 Workstation requirements . . . . . . . . . . . . . . . . . . . . . .

Page 83

70SNMP v3 SecuritySimple Network Management Protocol Version 3 (SNMPv3) is an interoperable standards-based protocol for network management. SNMPv3 pr

Page 84

HP SN6000 Fibre Channel Switch QuickTools Switch Management User Guide 71Adding an SNMP v3 userTo enable SNMP v3 security and add an SNMP v3 user:1. S

Page 85

72Modifying an SNMP v3 userTo modify an SNMP v3 user:1. Select the entry switch in the fabric tree.2. Select Switch > SNMP > SNMP v3 Manager to

Page 86

HP SN6000 Fibre Channel Switch QuickTools Switch Management User Guide 73Testing a switchThe Switch Diagnostics dialog box (Figure 36) enables you to

Page 87

74To test a switch:1. Open the faceplate display of the switch to be tested.2. Open the Switch menu and select Switch Diagnostics, and then select Onl

Page 88

HP SN6000 Fibre Channel Switch QuickTools Switch Management User Guide 75To archive a switch:1. Select Switch > Archive.2. In the Save dialog box,

Page 89 - Change Over

764. To restore all configuration settings, click the Full Restore tab, then click Restore. To restore selected configuration settings, click the Sele

Page 90

HP SN6000 Fibre Channel Switch QuickTools Switch Management User Guide 77FDMI HBA Entry Level 1000Subnet Mask Address 255.0.0.0Gateway Address 10.0.0.

Page 91 - 4 Managing Ports

78Installing feature license keysA feature license key is a password that enables you to upgrade your switch. To obtain a feature license key, contact

Page 92

HP SN6000 Fibre Channel Switch QuickTools Switch Management User Guide 79Downloading a support fileThe Download Support File menu option assembles all

Page 94 - Port Statistics data window

80After an NDCLA operation is complete, management connections must be re-initiated:• QuickTools sessions will re-connect automatically• Telnet sessio

Page 95

HP SN6000 Fibre Channel Switch QuickTools Switch Management User Guide 81To install firmware:1. Choose one of the following:• To install firmware on a

Page 96

82Table 16 describes the fields of the Call Home Setup dialog box.Table 16 Call Home Setup fields Field DescriptionPrimary SMTP: (active) (active) ind

Page 97 - Viewing and configuring ports

HP SN6000 Fibre Channel Switch QuickTools Switch Management User Guide 83Using the Call Home Profile ManagerThe Call Home Profile Manager is used to c

Page 98 - Port states

84Using the Call Home Profile EditorUse the Call Home Profile Editor dialog box (Figure 45) when creating a new profile, or when editing or copying an

Page 99 - Port administrative states

HP SN6000 Fibre Channel Switch QuickTools Switch Management User Guide 85To copy a profile:1. Select a profile from the list of profiles (Figure 44) i

Page 100 - Port speeds

86Using the Call Home Profile Editor—Tech Support Center Profile dialog boxYou can use the Call Home Profile Editor—Tech Support Center Profile dialog

Page 101 - Port transceiver media status

HP SN6000 Fibre Channel Switch QuickTools Switch Management User Guide 87Table 17 describes the fields in the Call Home Editor—Tech Support Center Pro

Page 102 - Resetting a port

88To create a Call Home Tech Support Center profile:1. Open the Switch menu, select Call Home, and then select Profile Manager.2. The Call Home Profil

Page 103 - Testing ports

HP SN6000 Fibre Channel Switch QuickTools Switch Management User Guide 89Using the Call Home Message QueueUse the Call Home Message Queue dialog box (

Page 104

HP SN6000 Fibre Channel Switch QuickTools Switch Management User Guide 91 Using QuickToolsThis chapter describes how to use the QuickTools web applet

Page 106 - Contacting HP

HP SN6000 Fibre Channel Switch QuickTools Switch Management User Guide 914 Managing PortsThe data windows provide port information and port statistics

Page 107 - Related information

92Table 18 Port Information data window fields Field DescriptionSummary GroupPort Address Port Fibre Channel address.Administrative Port Type The admi

Page 108

HP SN6000 Fibre Channel Switch QuickTools Switch Management User Guide 93Auto Performance Tuning Enables the switch to dynamically control the MFS_Ena

Page 109 - Glossary

94Port Statistics data windowThe Port Statistics data window (Figure 53) displays statistics for port performance. To open the Port Statistics data wi

Page 110

HP SN6000 Fibre Channel Switch QuickTools Switch Management User Guide 95BB_CreditRecoveryFrameFailureNumber of times more frames were lost during a c

Page 111

96LIP(F8,AL_PS) Denotes a loop failure detected by the L_port identified by AL_PS.LIP(F8,F7) A loop initialization primitive frame used to indicate t

Page 112

HP SN6000 Fibre Channel Switch QuickTools Switch Management User Guide 97Viewing and configuring portsPort color and text provide information about th

Page 113

98Port symbolic nameTo change the symbolic name of a port:1. Open the faceplate display and select a port.2. Select Port > Port Properties to open

Page 114

HP SN6000 Fibre Channel Switch QuickTools Switch Management User Guide 99Port administrative statesThe port administrative state determines the operat

Commentaires sur ces manuels