HP 3PAR Guide de l'utilisateur Page 351

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 676
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 350
EXAMPLES
The following example displays new customer alerts on a system:
cli% showalert -n
Id : 1
State : New
Message Code: 0x2200de
Time : 2008-07-17 20:14:29 PDT
Severity : Degraded
Type : Component state change
Message : Node 0, Power Supply 1, Battery 0 Degraded (Unknown)
Id : 2
State : New
Message Code: 0xe000c
Time : 2008-07-17 20:15:31 PDT
Severity : Informational
Type : Cluster shutdown after system recovery completion
Message : System recovery completed for node 0 (reason Power Loss)
2 alerts
NOTES
Set the status of alerts by issuing the setalert command. See setalert” (page 271) for more
information.
Alerts can be removed by issuing the removealert command. See removealert” (page 228)
for more information.