• LossSig. Loss of signal (electrical or optical) to the receiver port of a Fibre Channel node.
• PrimSeq. Primitive Sequence Protocol Error. There were errors during the transmission of a
Fibre Channel primitive sequence. This might indicate an error during the loop recovery or
initialization.
• InvWord. Invalid Transmission Word. Illegal Fibre Channel transmission word received.
• InvCRC. Invalid Cyclical Redundancy Check. Data corruption in the Fibre Channel frame.
NOTES
• If the both subcommand is specified, the resulting output text is greater than 80 columns
wide.
• Internal HP 3PAR counters are checked every 10 minutes.
• Each LESB counter is a 32-bit, unsigned integer.
• LESB counters on Fibre Channel devices cannot be reset.