Using Authorized IP Managers
Building IP Masks
Figure 8-5. Analysis of IP Mask for Multiple-Station Entries
1st
Octet
2nd
Octet
3rd
Octet
4th
Octet
Manager-Level or Operator-Level Device Access
IP Mask 255 255 255 0 The “255” in the first three octets of the mask specify that only the exact
Authorized 10 28 227 125
value in the octet of the corresponding IP address is allowed. However,
Manager IP
the zero (0) in the 4th octet of the mask allows any value between 0 and
255 in that octet of the corresponding IP address. This mask allows switch
access to any device having an IP address of 10.28.227.xxx, where xxx is
any value from 0 to 255.
IP Mask 255 255 255 249 In this example (figure 8-6, below), the IP mask allows a group of up to 4
Authorized 10 28 227 125
management stations to access the switch. This is useful if the only
devices in the IP address group allowed by the mask are management
IP Address
stations. The “249” in the 4th octet means that bits 0 and 3 - 7 of the 4th
octet are fixed. Conversely, bits 1 and 2 of the 4th octet are variable. Any
value that matches the authorized IP address settings for the fixed bits is
allowed for the purposes of IP management station access to the switch.
Thus, any management station having an IP address of 10.28.227.
121
, 123,
125
, or 127 can access the switch.
4th Octet of IP Mask:
4th Octet of Authorized IP Address:
249
5
Bit Numbers Bit Bit Bit Bit Bit Bit Bit Bit
7 6 5 4 3 2 1 0
Bit Values 128 64 32 16 8 4 2 1
4th Octet of
IP Mask (249)
4th Octet of
IP Authorized
Address (125)
Bits 1 and 2 in the mask are “off”, and bits 0 and 3
- 7 are “on”, creating a value of 249 in the 4th octet .
Where a mask bit is on”, the corresponding bit
setting in the address of a potentially authorized
station must match the IP Authorized Address
setting for that same bit. Where a mask bit is “off”
the corresponding bit setting in the address can be
either “on” or “off”. In this example, in order for a
station to be authorized to access the switch:
The first three octets of the station’s IP address
must match the Authorized IP Address.
Bit 0 and Bits 3 through 6 of the 4th octet in the
station’s address must be “on” (value = 1).
Bit 7 of the 4th octet in the station’s address
must be “off” (value = 0).
Bits 1 and 2 can be either “on” or “off”.
This means that stations with the IP address
13.28.227.X (where X is 121, 123, 125, or 127) are
authorized.
Figure 8-6. Example of How the Bitmap in the IP Mask Defines Authorized Manager Addresses
8-11
Vue de la page 216
1 2 ... 212 213 214 215 216 217 218 219 220 221 222 ... 227 228

Commentaires sur ces manuels

Pas de commentaire

Tripp Lite SU6000RT3UHVXL podręczniki

Instrukcje obsługi i podręczniki użytkownika dla Zasilacze bezprzerwowe (UPS) Tripp Lite SU6000RT3UHVXL.
Dostarczamy 1 pdf podręczników Tripp Lite SU6000RT3UHVXL do pobrania za darmo według typów dokumentów: Arkusz Danych






Więcej produktów i instrukcji dla Zasilacze bezprzerwowe (UPS) Tripp Lite

Modele Rodzaj dokumentu
SU3000RTXLCD3U Arkusz Danych   Tripp Lite SmartOnline 100-127V 3kVA 2.7kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 3U Rack, LCD display, USB, DB9 Serial, 6 strony
SU1000XLCD Arkusz Danych   Tripp Lite SmartOnline 100-127V 1kVA 900W On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, Tower, LCD display, USB, DB9 Serial, 6 strony
SU2200XLCD Arkusz Danych   Tripp Lite SmartOnline 100-127V 2.2kVA 1.8kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, Tower, LCD display, USB, DB9 Serial, 7 strony
SU2200RTXLCD2U Arkusz Danych   Tripp Lite SmartOnline 100-127V 2.2kVA 1.8kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 2U Rack/Tower, LCD display, USB, DB9 Serial, 7 strony
SU1000RTXLCD2U Arkusz Danych   Tripp Lite SmartOnline 100-127V 1kVA 900W On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 2U Rack/Tower, LCD display, USB, DB9 Serial, 6 strony
SU10KRT3/1X Arkusz Danych   Tripp Lite SmartOnline 3-Phase In/1-Phase Out 200-240V 10kVA 7kW On-Line, Double-Conversion UPS, Extended Run, SNMP, Webcard pre-installed, 6U Rack/Tower, USB, DB9 Serial, 5 strony
SMART2200RMXL2UP Arkusz Danych   Tripp Lite 2200 VA UPS, 6 strony
SM5000RT3UTAA Arkusz Danych   Tripp Lite SM5000RT3UTAA uninterruptible power supply (UPS), 6 strony
SMART1050SLTAA Arkusz Danych   Tripp Lite SMART1050SLTAA uninterruptible power supply (UPS), 6 strony
SMX3000RT2UTAA Arkusz Danych   Tripp Lite SMX3000RT2UTAA uninterruptible power supply (UPS), 6 strony
SU1500RTXLCD2U Arkusz Danych   Tripp Lite SmartOnline 100-127V 1.5kVA 1.35kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 2U Rack/Tower, LCD display, USB, DB9 Serial, 7 strony
HT-RL15UPS Arkusz Danych   Tripp Lite HTRL15UPS, 5 strony
SU16KRTHW Arkusz Danych   Tripp Lite SmartOnline 200-240V, 16kVA 14.4kW On-Line Double-Conversion UPS, N+1, Extended Run, SNMP, Webcard, 12U Rack/Tower, USB, DB9 Serial, Hardwire, 6 strony
SU5000RT4UTF Arkusz Danych   Tripp Lite SmartOnline 208/120V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, USB, DB9 Serial, 6 strony
SU12000RT4UHW Arkusz Danych   Tripp Lite SmartOnline 240/120V or 208/120V 12kVA 8.4kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 8U, USB, DB9 Serial, Hardwire, 6 strony
SU20KX Arkusz Danych   Tripp Lite SmartOnline 20kVA 16kW Modular 3-Phase UPS System, On-line Double-Conversion UPS, SNMP, Webcard, DB9 Serial, 5 strony
SU6000RT4UTF Arkusz Danych   Tripp Lite SmartOnline 240/208/120V 6kVA 5.4kW On-Line Double-Conversion UPS, Low-Voltage Transformer, Extended Run, SNMP, Webcard, 6U Rack/Tower, Bypass Switch, 7 strony
SU6000RT4UHVHW Arkusz Danych   Tripp Lite SmartOnline 200-240V 6kVA 5.4kW On-Line Double-Conversion UPS, Extended run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial, Hardwire, 6 strony
SU3000RTXR3UHW Arkusz Danych   Tripp Lite SmartOnline 110-120V 3kVA 2.4kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 3U Rack/Tower, USB, DB9 Serial, Hardwire, 6 strony
SU40K Arkusz Danych   Tripp Lite SU40K uninterruptible power supply (UPS), 6 strony