HP G250 Manuel d'utilisateur Page 30

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 76
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 29
Optional components
30 Overview for the Avaya G250 and Avaya G350 Media Gateways
The circuit-switched connections have an A- or Mu-law option for voice operation. The
circuit-switched connections operate as 64-kbps clear channels when in the data mode.
For BRI endpoints, the MM720 BRI media module supports up to 16 BRI stations and data
modules that conform to AT&T BRI, World Class BRI, and National ISDN NI1/NI2 BRI standards.
The MM720 BRI media module provides -40 volt phantom power to the BRI endpoints.
Figure 15: The MM720 media module
MM722 BRI media module
The MM722 BRI media module provides two 4 wire S/T ISDN BRI 2B+D access ports with
RJ-45 jacks. Each port interfaces to the central office at the ISDN T reference point. Information
is communicated in the same manner as for the MM720. See MM720 BRI media module
on
page 29.
Figure 16: The MM722 media module
Note:
Note: The MM722 media module does not support BRI stations or combining both B
channels together to form a 128-kbps channel.