HP Moonshot-45XGc Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Commutateurs de réseau HP Moonshot-45XGc. HP Moonshot-45XGc User's Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 43
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
HP Moonshot-45XGc Switch
User and Maintenance Guide
Abstract
This document is for the person who installs, administers, services, and troubleshoots switches. This guide provides identifi
cation, setup, installation,
and removal procedures. HP assumes you are qualified in these areas.
Part Number: 796044-001
September 2014
Edition: 1
Vue de la page 0
1 2 3 4 5 6 ... 42 43

Résumé du contenu

Page 1 - User and Maintenance Guide

HP Moonshot-45XGc Switch User and Maintenance Guide Abstract This document is for the person who installs, administers, services, and troubleshoots

Page 2

Operations 10 4. After performing the installation or maintenance procedure, slide the chassis back into the rack, and then press the chassis firmly

Page 3 - Contents

Operations 11 3. Lift and remove the access panel. Turn the access panel over to locate the HP Moonshot 1500 Chassis label. This label provides inf

Page 4 - Contents 4

Operations 12 Remove the uplink module blank Remove the component as indicated. Remove the switch module blank Remove the component as indicated.

Page 5

Setup 13 Setup Installation information and guidelines Before installing the module, review the following: • Always install the switch module and t

Page 6 - • HP QSFP+ to SFP+ Adapter

Setup 14 Uplink module bays The uplink module can be installed in the uplink module bays located in the rear of the chassis. Installing the uplink

Page 7 - Item Description Status

Setup 15 2. Prepare the uplink module for installation. 3. Install the uplink module. 4. Do one of the following: o If the switch module is alr

Page 8 - Moonshot switch module LEDs

Setup 16 3. Locate the switch module slot and remove the blank. 4. Prepare the switch module for installation.

Page 9 - Operations

Setup 17 5. Align and install the switch module into the chassis. 6. Do one of the following: o If the uplink module is already installed, verify

Page 10 - Remove the access panel

Cabling 18 Cabling Supported cables and transceivers The following cables and transceiver modules are supported for the HP Moonshot-4QSFP+ Uplink Mo

Page 11 - Operations 11

Cabling 19 Installing a transceiver WARNING: To avoid serious injury, never look directly into an open transceiver port. CAUTION: Disconne

Page 12 - Operations 12

© Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warranties

Page 13 - Setup 13

Cabling 20 o Transceiver adapter If a cable needs to be connected, remove any dust plugs or covers, and then connect the cable.

Page 14 - Installing the uplink module

Command Line Interface 21 Command Line Interface Connecting to the switch console To connect to the switch console, use one of the following methods

Page 15 - Installing the switch module

Command Line Interface 22 Accessing the CLI remotely Remote administration of the switch occurs through the iLO/MGMT port, located on the iLO CM mod

Page 16 - Setup 16

Command Line Interface 23 o show switch power o show switch temperature To set switch power or switch UID LED: o set switch power {off|on} {sa|sb|

Page 17

Configuration 24 Configuration Switch documentation To configure the switch, see the switch configuration guides in the HP Moonshot Switch Informati

Page 18 - Cabling

Firmware 25 Firmware Update the switch firmware Before updating switch firmware, see the "Upgrading software" section of the HP Moonshot-4

Page 19 - Installing a transceiver

Network mapping 26 Network mapping Production network mapping The first network interface discovered by the operating system routes traffic through

Page 20 - Transceiver adapter

Network mapping 27 Management network mapping All traffic from the service port management interface is routed through the iLO CM management port.

Page 21 - Command Line Interface

Network mapping 28 Moonshot-4QSFP+ uplink interfaces Item Port Port speed Interface 1 Q1 40Gb 10Gb fortygige1/1/1 ten-gigabitethernet1/1/1:1–4

Page 22 - Accessing the CLI using iLO

Network mapping 29 Moonshot-45XGc downlink interfaces Interfaces 1/0/1–1/0/45 are the downlinks to the cartridge nodes. Each SoC is identified as a

Page 23

Contents 3 Contents Component and LED identification ...

Page 24 - Configuration

Troubleshooting 30 Troubleshooting Troubleshooting resources The HP Moonshot System Troubleshooting Guide provides procedures for resolving common p

Page 25 - Firmware

Illustrated parts catalog 31 Illustrated parts catalog Customer self repair HP products are designed with many Customer Self Repair (CSR) parts to m

Page 26 - Network mapping

Illustrated parts catalog 32 Switch customer self repair components Item Description Spare part number Customer self repair (on page 31) 1 HP Mo

Page 27 - Interfaces

Removal and replacement procedures 33 Removal and replacement procedures Removing the switch module CAUTION: Be sure to save the running-configu

Page 28

Removal and replacement procedures 34 CAUTION: For proper cooling, be sure every switch module bay and uplink module bay has either a blank or a mo

Page 29 - Network mapping 29

Regulatory information 35 Regulatory information Safety and regulatory compliance For safety, environmental, and regulatory information, see Safety

Page 30 - Troubleshooting

Electrostatic discharge 36 Electrostatic discharge Preventing electrostatic discharge To prevent damaging the system, be aware of the precautions yo

Page 31 - Illustrated parts catalog

Specifications 37 Specifications Chassis environmental specifications Specification Value Temperature range* — Operating 10°C to 35°C (50°F to 95°

Page 32

Support and other resources 38 Support and other resources Before you contact HP Be sure to have the following information available before you call

Page 33 - Removing the uplink module

Acronyms and abbreviations 39 Acronyms and abbreviations CM chassis management CMU HP Insight Cluster Management Utility CSR Customer Self Repair

Page 34

Contents 4 Customer self repair ...

Page 35 - Regulatory information

Acronyms and abbreviations 40 SFTP Secure File Transfer Protocol SoC system on chip SR short range SSH Secure Shell TFTP Trivial File Transfer P

Page 36 - Electrostatic discharge

Documentation feedback 41 Documentation feedback HP is committed to providing documentation that meets your needs. To help us improve the documentat

Page 37 - Specifications

Index 42 A access panel 10 activity LED 5 administration 24 authorized reseller 38 B before you contact HP 38 blank, removal 12 C cable

Page 38 - Support and other resources

Index 43 T technical support 38 troubleshooting 30 U updating firmware 25 uplink module 14 uplink module bay identification 13, 14 uplink

Page 39 - Acronyms and abbreviations

Component and LED identification 5 Component and LED identification Chassis front panel LEDs and buttons Item Description LED Status 1 Chassi

Page 40

Component and LED identification 6 Moonshot-4QSFP uplink module components Item Component Description 1 Serial console port For management 2

Page 41 - Documentation feedback

Component and LED identification 7 Moonshot-4QSFP uplink module buttons and LEDs Item Description Status 1 Uplink module UID LED/button Solid bl

Page 42 - Index 42

Component and LED identification 8 Moonshot switch module LEDs Item Description Status 1 Switch module power LED Green = Normal operation Amber

Page 43 - Index 43

Operations 9 Operations Extend the chassis from the rack 1. Pull down the quick release levers on each side of the chassis. WARNING: To reduce

Commentaires sur ces manuels

Pas de commentaire