17
Figure 14 Grounding through the PE wire of the AC power cord
(1) Three-wire AC power cable (2) Chassis rear panel
NOTE:
To guarantee the grounding effect, use the grounding cable provided with the switch to connect to the
grounding strip in the equipment room as long as possible.
Installing/removing a fan tray
CAUTION:
To ensure good ventilation for the switch:
• Install two fan trays of the same model on the switch.
• Do not power on the switch when no or only one fan tray is installed.
• If one fan tray fails, perform the following tasks:
{ Finish replacing the fan tray within 24 hours and do not remove the failed fan tray before replacement when
the ambient temperature is below 27°C (80.6°F).
{ Replace the fan tray immediately when the ambient temperature is above 27°C (80.6°F).
• If both fan trays fail, finish replacing the fan trays within 2 minutes.
Installing a fan tray
CAUTION:
To prevent damage to the fan tray or the connectors on the backplane, insert the fan tray gently. If you
encounter a hard resistance while inserting the fan tray, pull out the fan tray and insert it again.
1
2