HP ProLiant DL140 Generation 3 Server Software Configuration User Guide Part number: 416132-001 First edition: October 2006
System BIOS configuration 10 Advanced Chipset Control submenu Figure 6 Advanced Chipset Control submenu Table 6 Advanced Chipset Control submenu
System BIOS configuration 11 USB Control submenu The USB Control submenu allows users to select which functions to enable for available USB device
System BIOS configuration 12 Table 7 Advanced Processor Options submenu fields Field Description Options Discrete MTRR Allocation If enabled, Me
System BIOS configuration 13 PCI Slots Configuration submenu Figure 11 PCI Slots Configuration submenu Table 9 PCI Slots Configuration submenu fi
System BIOS configuration 14 Console Redirection submenu Figure 13 Console Redirection submenu Table 11 Console Redirection submenu fields Fiel
System BIOS configuration 15 IPMI submenu Figure 14 IPMI submenu Table 12 IPMI submenu fields Field Description IPMI Specification Version Syste
System BIOS configuration 16 Table 13 LAN Settings submenu fields Field Description Options BMC Telnet Service Select whether to enable the BMC
System BIOS configuration 17 Realtime Sensor Data submenu The Realtime Sensor Data submenu displays the current values for various hardware monito
System BIOS configuration 18 To change the administrator password: 1. In the Security menu screen, select the Administrator Password Is field,
System BIOS configuration 19 Power menu Figure 22 Setup Power menu Table 16 Power menu fields Field Description Options Resume on Modem Ring Se
2 Legal notices © Copyright 2006 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The
System BIOS configuration 20 Boot-time diagnostic screen The boot-time diagnostic screen displays basic and important information about the cur
System BIOS configuration 21 CMOS backup utility There are third-party utilities that read the CMOS settings and record them to a regular file, w
System BIOS configuration 22 Power-On Self Test (POST) When the server boots up, a series of tests are displayed on the screen. This is referre
System BIOS configuration 23 Table 18 POST error messages Error code Error message Description/corrective action 0251 System CMOS checksum ba
System BIOS configuration 24 Table 19 lists the checkpoint codes written at the start of each test and the beep codes issued for terminal errors.
System BIOS configuration 25 Table 19 POST beep codes Code Beep Description 45h POST device initialization 46h 2-1-2-3 Check ROM copyright no
System BIOS configuration 26 Table 19 POST beep codes Code Beep Description 84h Detect and install external parallel ports 85h Initialize P
System BIOS configuration 27 Table 19 POST beep codes Code Beep Description BCh Clear parity checkers BDh Display Multi-boot menu BEh Clea
System BIOS configuration 28 Table 19 POST beep codes Code Beep Description F4h Output one beep F5h Clear huge segment F6h Boot to mini
RAID configuration 29 RAID configuration RAID overview RAID–redundant array of independent (originally, inexpensive) disks–is a method of replic
Contents 3 Contents System BIOS configuration System BIOS overview...
RAID configuration 30 9. In the Option menu box, select Array Configuration Utility. 10. In the Main Menu box, select Configure Drives. 11. Se
Network operating system (NOS) installation 31 Network operating system (NOS) installation Supported NOS Table 20 List of supported NOS NOS Vers
Network operating system (NOS) installation 32 Installing Microsoft Windows NOS The procedures in this section apply to all Microsoft Windows NO
Network operating system (NOS) installation 33 2. Follow the procedures corresponding to the type of hard disk that is installed in the server. 3
Network operating system (NOS) installation 34 Phase 2 - Installing the HP LAN driver During the Windows NOS installation, the OS may not detect
Network operating system (NOS) installation 35 3. Verify if the installed drivers are digitally signed. a. In the Device Manager window, select
Network operating system (NOS) installation 36 11. Click Start | Settings | Control Panel | Administrative Tools. 12. Check that the following
Network operating system (NOS) installation 37 To test the network link using Terminal Services: 1. Click Start | Programs | Terminal Services Cl
Network operating system (NOS) installation 38 Section 6. Installing additional HP accessories The HP ProLiant DL140 Generation 3 Server Support
Network operating system (NOS) installation 39 Installing Red Hat Enterprise Linux NOS Installation flow 1. Install Red Hat Enterprise Linux 3
System BIOS configuration 4 System BIOS configuration System BIOS overview Basic Input/Output System or BIOS is a set of programs permanently st
Network operating system (NOS) installation 40 Disk Partitioning Setup HP recommends selecting the automatic partitioning mode. 1. Click Autopar
Network operating system (NOS) installation 41 Section 3. Installing Red Hat Enterprise Linux 3 Installation to Begin Once you complete the custom
Network operating system (NOS) installation 42 Section 2. Customizing the installation Language Selection Select the language of choice you prefe
Network operating system (NOS) installation 43 Section 3. Installing Red Hat Enterprise Linux 4 About to Install Once you complete the customizati
Network operating system (NOS) installation 44 Installing SUSE Linux Enterprise Server NOS The procedures in this section apply to the SUSE Linu
Network operating system (NOS) installation 45 Section 3. Completing the installation Root Password Enter a root password consisting of at least s
Network operating system (NOS) installation 46 Section 1. Installing SUSE Linux Enterprise Server 10 1. Turn on the server and insert the SUSE L
Network operating system (NOS) installation 47 Add a New Local User Follow the prompt to add a new local user account, then click Next to continue
Network operating system (NOS) installation 48 Installing Sun Solaris 10 Perform the procedures in this section to install Sun Solaris 10 to yo
Network operating system (NOS) installation 49 Section 2. Customizing the installation The Sun Solaris10 Installer shifts to a text-based screen f
System BIOS configuration 5 Accessing the Setup Utility 1. Turn on the monitor and the server. If the server is already turned on, save your d
Network operating system (NOS) installation 50 Section 3. Completing the installation Welcome The Welcome screen appears. Click Next to proceed w
Server management 51 Server management Server management overview Server management on the HP ProLiant DL140 G3 provides the user with the status
Server management 52 Remote management interfaces The following paragraphs provide examples on how to use the various interfaces. The CLI and KCS
Server management 53 6. From the remote system open a DOS window and type in telnet <server’s IP address>. 7. Enter the login name and pas
Server management 54 7. Start connection by clicking the phone icon on the HyperTerminal toolbar. 8. Press Esc once, then press Shift + 9. Thi
Index 55 Index A administrator password: changing, 18; definition, 17; removing, 18; resetting, 18; setting, 17 B Basic Input/Output System. See BI
System BIOS configuration 6 Table 1 Setup Utility’s navigation keys Key Function F1 or Alt-H To bring up the General Help window. The General
System BIOS configuration 7 IDE Channel 0 Master/SATA Port 1/SATA Port 2 submenu Figure 3 IDE Channel 0 Master/SATA Port 1/SATA Port 2 submenu Ta
System BIOS configuration 8 Boot Features submenu Figure 4 Boot Feature submenu Table 4 Boot Features submenu fields Field Description Options
System BIOS configuration 9 Advanced menu Figure 5 Setup Advanced menu Table 5 Advanced menu fields Field Description Options Reset Configurati
Commentaires sur ces manuels