Combining improved 1U compute performance, smart power and cooling management with infrastructure management tools and
essential fault tolerance, the HP ProLiant DL360 G6 is optimized for space constrained operations.
With select Intel 5500/5600 Series Xeon® Processors (Six-Core, Quad-Core and Dual-Core), with choice of DDR3 Registered or
Unbuffered DIMMs, integrated HP Smart Array for SATA, SAS and SSD hard drive support, PCI Express Gen2 technology and
ProLiant iLO management The DL360 G6 provides a high performance system, ideal for the full range of scale out applications.
What's more, the DL360 G6 steps up the fault tolerant in an ultra-dense platform with redundant power, redundant fans, mirrored
memory and embedded RAID capability.
Front View:
Front View:Front View:
Front View:
Rear View:
Rear View:Rear View:
Rear View:
1.
Quick removal access panel with installation instructions
1.
PCI Express expansion slot 1, low-profile, half-length
2.
Up to two Intel Quad-Core or Dual-Core Xeon™
5500/5600 series processors)
2.
PCI Express expansion slot 2 full height full length x16 (16,
8, 4, 2, 1), 75W +EXT 75W (optional PCI-X card only
support)
3.
Video Connector
3.
Power supply 1
4.
Slide-out System Insight Display
4.
Power supply 2
5.
Removable fan modules for easy serviceability
5.
iLO 2 NIC connector
6.
Eighteen DIMM slots for DDR3 Registered (RDIMM) or
Unbuffered (UDIMM) memory
6.
Serial connector
7.
2 Redundant Common Slot Hot Plug Power Supplies
(upgradeable option)
7.
Video connector
8.
2 PCI-E Slots
9.
Keyboard connector
10.
NIC 2 connector
11.
NIC 1 connector
12.
USB connector
13.
USB connector
QuickSpecs
HP ProLiant DL360 Generation 6 (G6)
HP ProLiant DL360 Generation 6 (G6)HP ProLiant DL360 Generation 6 (G6)
HP ProLiant DL360 Generation 6 (G6)
Overview
DA - 13235 Worldwide — Version 38 — October 14, 2011
Page 1
Vue de la page 0
1 2 3 4 5 6 ... 52 53

Résumé du contenu

Page 1 - QuickSpecs

Combining improved 1U compute performance, smart power and cooling management with infrastructure management tools andessential fault tolerance, the H

Page 2

Factory Express PortfolioFactory Express PortfolioFactory Express PortfolioFactory Express Portfoliofor Servers and Storagefor Servers and Storagefor

Page 3

Service and SupportService and SupportService and SupportService and SupportHP Care Pack Services: Packaged server and storage services for increased

Page 4

Recommended HP Care Pack Services for optimal satisfaction with your HP productRecommended HP Care Pack Services for optimal satisfaction with your HP

Page 5

Optional HP Care Pack Services that will enhance your HP product experienceOptional HP Care Pack Services that will enhance your HP product experience

Page 6

X 7, so you can spend less time solving problems and more time focused on your business. You canhave your systems remotely monitored for hardware fail

Page 7

NOTE:NOTE:NOTE:NOTE: For the Standard Features shipped in the "Factory Integrated Models", please see the "Configuration Information -

Page 8

WarrantyWarrantyWarrantyWarrantyServer Warranty includes 3-Year Parts, 3-Year Labor, 3-Year Onsite supportwith next business day response.Base ModelsB

Page 9

Entry ModelEntry ModelEntry ModelEntry ModelQuad-Core ModelsQuad-Core ModelsQuad-Core ModelsQuad-Core ModelsDL360G6 E5504 4GBDL360G6 E5504 4GBDL360G6

Page 10

NOTE:NOTE:NOTE:NOTE: This section lists some of the steps required to configure a Factory Integrated Model. To ensure only valid configurations areord

Page 11

NOTE:NOTE:NOTE:NOTE: HT indicates that the processor model supports Intel® /Hyper-ThreadingTechnologyNOTE:NOTE:NOTE:NOTE: Turbo indicates the maximum

Page 12

NOTE:NOTE:NOTE:NOTE: For the Standard Features shipped in the "Factory Integrated Models", please see the "Configuration Information -

Page 13

Step 3: Choose Additional Factory Integratable OptionsStep 3: Choose Additional Factory Integratable OptionsStep 3: Choose Additional Factory Integrat

Page 14

NOTE:NOTE:NOTE:NOTE: Some options may not be factory integratable. Contact your local sales representative for additional information.HP Unique Option

Page 15

HP MemoryHP MemoryHP MemoryHP MemoryRegistered DIMMs (RDIMMs)Registered DIMMs (RDIMMs)Registered DIMMs (RDIMMs)Registered DIMMs (RDIMMs)HP 2GB (1x2GB)

Page 16

HP Hard DrivesHP Hard DrivesHP Hard DrivesHP Hard DrivesNOTE:NOTE:NOTE:NOTE: The components of a storage subsystem (e.g. the drive, the HBA/controller

Page 17

HP NetworkingHP NetworkingHP NetworkingHP NetworkingGigabit Ethernet AdaptersGigabit Ethernet AdaptersGigabit Ethernet AdaptersGigabit Ethernet Adapte

Page 18

HP Insight SoftwareHP Insight SoftwareHP Insight SoftwareHP Insight SoftwareHP Insight ControlHP Insight ControlHP Insight ControlHP Insight Control H

Page 19

HP iLO Advanced including 1yr 24x7 Technical Support and Updates Single ServerLicense512485-B21NOTE:NOTE:NOTE:NOTE: This license allows 1 server to be

Page 20

HP Security - TPMHP Security - TPMHP Security - TPMHP Security - TPMHP Trusted Platform Module Option Kit488069-B21NOTE:NOTE:NOTE:NOTE: The TPM (Trust

Page 21

HP 8484 to Mini SAS 33in Cable AssemblyNOTE:NOTE:NOTE:NOTE: Cable for use connecting the Smart Array P800 Controller to internal harddisk drives on se

Page 22

NOTE:NOTE:NOTE:NOTE: Please see the QuickSpecs for additional information:http://h18000.www1.hp.com/products/quickspecs/12566_div/12566_div.html(SC11X

Page 23

UpgradeabilityUpgradeabilityUpgradeabilityUpgradeabilityUpgradeable to two processorsMemory ProtectionMemory ProtectionMemory ProtectionMemory Protect

Page 24

HP StorageWorks 1/8 G2 LTO-5 Ultrium 3000 SAS Tape AutoloaderNOTE:NOTE:NOTE:NOTE: Requires HP 1U Tape Autoloader Rack Kit (AH166A) for rack installati

Page 25

HP StorageWorksHP StorageWorksHP StorageWorksHP StorageWorksOptionsOptionsOptionsOptionsStorageWorks Fibre Channel HBAStorageWorks Fibre Channel HBASt

Page 26

HP Uninterruptible PowerHP Uninterruptible PowerHP Uninterruptible PowerHP Uninterruptible PowerSystemsSystemsSystemsSystemsHP Rack-mountable UPSHP Ra

Page 27

HP Modular Power Distribution Units (mPDU), High Volt Model, 16A (200-240 VAC)(WW)NOTE:NOTE:NOTE:NOTE: This PDU has a detachable input power cord and

Page 28

HP Rack OptionsHP Rack OptionsHP Rack OptionsHP Rack OptionsKeyboards and MonitorsKeyboards and MonitorsKeyboards and MonitorsKeyboards and Monitors H

Page 29

HP USB and SD OptionsHP USB and SD OptionsHP USB and SD OptionsHP USB and SD OptionsHP USB 2-Button Optical Scroll Mouse (Carbonite/Silver)DC172BHP US

Page 30

NOTE:NOTE:NOTE:NOTE: Memory configurations listed do not apply to "Factory Integrated Models".DDR3 memory population guidelinesDDR3 memory p

Page 31

POPULATED DIMM SPEED (MHz)1 DIMM Per Channel1333 1333 1333 1066 1066 1066 1333 13332 DIMM Per Channel1333*1333*1333*1066800 8001333*1333*3 DIMM Per Ch

Page 32

CPU1CPU1CPU1CPU1 CPU2CPU2CPU2CPU2 slot #population orderslot #population order Chnl 11G; empty1G; emptyChnl 12D; empty2D; empty3A; 2GB DIMM3A; empty

Page 33

CPU1CPU1CPU1CPU1 CPU2CPU2CPU2CPU2 slot #population orderslot #population order Chnl 11G; 8GB DIMM1G; emptyChnl 12D; 8GB DIMM2D; empty3A; 8GB DIMM3A;

Page 34

Storage ControllerStorage ControllerStorage ControllerStorage ControllerOne of the followingdepending on ModelEntry ModelsHP Smart Array P410i/Zero Me

Page 35

CPU1CPU1CPU1CPU1 CPU2CPU2CPU2CPU2 slot #population orderslot #population order Chnl 11G; empty1G; emptyChnl 12D; 16GB DIMM2D; 16GB DIMM3A; 16GB DIMM

Page 36

Following are memory options available from HP:Following are memory options available from HP:Following are memory options available from HP:Follo

Page 37

1-88 x SFF SAS Hot Pluggable Hard Drive Bays. OpticalMedia Bay not available for this configuration1-44 x SFF SAS Hot Pluggable Hard DrivesAOptical Me

Page 38

146GB 6G SAS 10K DP72GB 6G SAS 15K DPHP Smart Array P410i/256 MB ControllerHP Smart Array P410i/512 MB BBWC ControllerHP Smart Array P411/256 MB Contr

Page 39

HP Smart Array P411/512 MB BBWC ControllerHP Smart Array P411/512 MB FBWC ControllerHP Smart Array P411/1G FBWC ControllerHP Smart Array P812/1G Flash

Page 40

Tape and Disk BackupTape and Disk BackupTape and Disk BackupTape and Disk BackupNOTE:NOTE:NOTE:NOTE: For the complete range of StorageWorks tape drive

Page 41

HP StorageWorks SCSIHP StorageWorks SCSIHP StorageWorks SCSIHP StorageWorks SCSITape Libraries, ExternalTape Libraries, ExternalTape Libraries, Extern

Page 42

HP 460W HE 12V Hot Plug AC Power Supply KitHP 460W HE 12V Hot Plug AC Power Supply KitHP 460W HE 12V Hot Plug AC Power Supply KitHP 460W HE 12V Hot Pl

Page 43

HP 1200W 12V Hot Plug AC Power SupplyHP 1200W 12V Hot Plug AC Power SupplyHP 1200W 12V Hot Plug AC Power SupplyHP 1200W 12V Hot Plug AC Power SupplyPa

Page 44

System UnitSystem UnitSystem UnitSystem UnitDimensionsDimensionsDimensionsDimensions (H x W x D)(with bezel)1.70 x 16.78 x 27.25 in (4.32 x 42.62 x 69

Page 45

Industry StandardIndustry StandardIndustry StandardIndustry StandardComplianceComplianceComplianceComplianceACPI 2.0b CompliantPCI 2.2 CompliantPXE Su

Page 46

Non-operating5 to 95% relative humidity (Rh), 38.7° C (101.7°F) maximum wet bulb temperature, non-condensing.AltitudeAltitudeAltitudeAltitudeOperating

Page 47

NOTE:NOTE:NOTE:NOTE: Product conformance to cited product specifications is based onsample (type) testing, evaluation, or assessment. This product or

Page 48

Embedded NC382i DualEmbedded NC382i DualEmbedded NC382i DualEmbedded NC382i DualPort Multifunction GigabitPort Multifunction GigabitPort Multifunction

Page 49

© Copyright 2011 Hewlett-Packard Development Company, L.P.The information contained herein is subject to change without notice.Intel, the Intel logo,

Page 50

System FansSystem FansSystem FansSystem Fans1P Models3 fan modules ship standard2P Models4 fan modules ship standardFan redundancy standard with all m

Page 51

HP Insight managementHP Insight managementHP Insight managementHP Insight managementsoftwaresoftwaresoftwaresoftwareHP Insight FoundationManaging the

Page 52

WarrantyWarrantyWarrantyWarrantyThis product is covered by a global limited warranty and supported by HP Services and a worldwidenetwork of HP Authori

Page 53

HP Insight managementHP Insight managementHP Insight managementHP Insight managementsoftwaresoftwaresoftwaresoftwareHP Insight ControlHP Insight Contr

Commentaires sur ces manuels

Pas de commentaire