HP 2012fc Modular Smart Array
user guide
Part number: 481597-002
First edition: January, 2013
Vue de la page 0
1 2 3 4 5 6 ... 87 88

Résumé du contenu

Page 1 - First edition: January, 2013

HP 2012fc Modular Smart Array user guidePart number: 481597-002First edition: January, 2013

Page 2

10 HP 2012fc Modular Smart Array user guide • January 2013Subscription ServiceHP strongly recommends that customers sign up online using the Subscribe

Page 3 - Contents

11CHAPTER1Before You BeginThe MSA2000 Family 2012fc Modular Smart Array and MSA2000 Drive Enclosure are high-performance storage solutions that combin

Page 4

12 HP 2012fc Modular Smart Array user guide • January 2013System Management SoftwareEmbedded management software includes a web-browser interface and

Page 5 - Contents 5

Chapter 1 Before You Begin 13Hardware Components and LEDsThis section describes the main hardware components of your storage system enclosures.Control

Page 6

14 HP 2012fc Modular Smart Array user guide • January 2013Figure 1-1 shows the LEDs on the front of a controller.Figure 1-1 Controller (Front View)Tab

Page 7 - About This Guide

Chapter 1 Before You Begin 15Table 1-3 describes the LEDs on the drive module. Table 1-3 Drive Module LED Combinations (Front)Online/Activity(green)F

Page 8 - Rack Stability

16 HP 2012fc Modular Smart Array user guide • January 2013Figure 1-2 shows the ports and switches at the back of the controller.Figure 1-2 Controller

Page 9 - Product Warranties

Chapter 1 Before You Begin 17Figure 1-3 shows the LEDs at the back of the controller.Figure 1-3 Controller LEDs (Back View)Table 1-5 describes the LE

Page 10 - Documentation Feedback

18 HP 2012fc Modular Smart Array user guide • January 2013Controller moduleUnit LocatorWhite Off Normal operation.Blink Physically identifies the cont

Page 11 - Before You Begin

Chapter 1 Before You Begin 19Drive Enclosure Components and LEDsA drive enclosure can be connected to a controller enclosure or to another drive enclo

Page 12 - System Management Software

Legal and notice information© Copyright 2008, 2013 Hewlett-Packard Development Company, L.P.Hewlett-Packard Company makes no warranty of any kind with

Page 13 - Hardware Components and LEDs

20 HP 2012fc Modular Smart Array user guide • January 2013Figure 1-4 shows the ports and switches at the back of the drive enclosure.Figure 1-4 Drive

Page 14

Chapter 1 Before You Begin 21Figure 1-5 shows the LEDs at the back of the drive enclosure.Figure 1-5 Drive Enclosure LEDs (Back View)Table 1-8 descri

Page 15 - Online/Activity

22 HP 2012fc Modular Smart Array user guide • January 2013Expansion moduleFault/Service RequiredAmber On A fault has been detected or a service action

Page 16 - Service port

Chapter 1 Before You Begin 23Installation ChecklistTable 1-9 outlines the steps required to install the enclosures and initially configure the system.

Page 17 - LINK SPEED LINK SPEED

24 HP 2012fc Modular Smart Array user guide • January 2013

Page 18

25CHAPTER2Installing and Cabling EnclosuresThis chapter describes how to install and cable enclosures in a standard 19-inch EIA rack cabinet. It conta

Page 19 - Description Quantity

26 HP 2012fc Modular Smart Array user guide • January 2013Safety PrecautionsFor your protection, observe the following safety precautions when setting

Page 20 - SAS In port

Chapter 2 Installing and Cabling Enclosures 27Installing Enclosures Into a RackThis section describes how to install the enclosures into a standard 19

Page 21 - Chapter 1 Before You Begin 21

28 HP 2012fc Modular Smart Array user guide • January 2013Rack Installation Overview and ProcedureFigure 2-1 provides a visual overview of rack instal

Page 22

Chapter 2 Installing and Cabling Enclosures 29Use the following procedure and refer to Figure 2-1 to install each enclosure into the rack.When positio

Page 23 - Installation Checklist

3ContentsAbout This Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7Intended Audience .

Page 24

30 HP 2012fc Modular Smart Array user guide • January 2013Figure 2-2 Side Bracket With Alignment Marksb. On one side, insert the first two screws thr

Page 25 - Required Tools

Chapter 2 Installing and Cabling Enclosures 31Attaching the Ear CapsThe plastic ear caps are snap-on parts that require some care when attaching or re

Page 26 - Safety Precautions

32 HP 2012fc Modular Smart Array user guide • January 2013Connecting Controller and Drive Enclosures Use the supplied SAS cables to connect a controll

Page 27 - Preparing the Rack

Chapter 2 Installing and Cabling Enclosures 33Figure 2-5 Fault-Tolerant Cabling Connections Between One Controller Enclosure and Up to Three Drive En

Page 28

34 HP 2012fc Modular Smart Array user guide • January 2013Figure 2-6 Non-Fault-Tolerant Cabling Connections Between One Controller and Up to Three Dr

Page 29

Chapter 2 Installing and Cabling Enclosures 35Connecting AC PowerUse this procedure to connect AC power to the enclosures.1. Verify that both power sw

Page 30

36 HP 2012fc Modular Smart Array user guide • January 2013Testing the Enclosure ConnectionsUse this procedure to power on the newly installed system.1

Page 31 - Attaching the Ear Caps

Chapter 2 Installing and Cabling Enclosures 37Correcting Enclosure IDs When installing a system with drive enclosures attached, the enclosure IDs migh

Page 32 - Drive Enclosure

38 HP 2012fc Modular Smart Array user guide • January 2013

Page 33

39CHAPTER3Connecting HostsThis chapter describes how to connect data and management hosts to controller enclosures. It contains the following sections

Page 34

4 HP 2012fc Modular Smart Array user guide • January 2013Installing Enclosures Into a Rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 35 - Connecting AC Power

40 HP 2012fc Modular Smart Array user guide • January 2013Installing the MSA2000 Family SES Driver for Microsoft Windows HostsInstalling the MSA2000 F

Page 36 - –) position

Chapter 3 Connecting Hosts 41Using Host Port InterconnectsWhen the internal connections between host ports are enabled through SMU, host port 0 on eac

Page 37 - Next Steps

42 HP 2012fc Modular Smart Array user guide • January 2013Connecting Direct Attach ConfigurationsThis section explains how to connect the controller e

Page 38

Chapter 3 Connecting Hosts 43Figure 3-2 shows a non-redundant configuration that can be used when high performance is more important than high availab

Page 39 - Connecting Hosts

44 HP 2012fc Modular Smart Array user guide • January 2013Connecting Switch Attach ConfigurationsThis section explains how to connect the controller e

Page 40 - Configuration Considerations

Chapter 3 Connecting Hosts 45Connecting One Data Host Through One SwitchFigure 3-3 shows a dual-controller connection through one switch to one dual-p

Page 41 - Using Host Port Interconnects

46 HP 2012fc Modular Smart Array user guide • January 2013Connecting Two Data Hosts Through Two SwitchesFigure 3-4 shows the preferred high-availabili

Page 42 - Dual-Port Data Hosts

Chapter 3 Connecting Hosts 47Connecting Two Data Hosts Through a Zoned SwitchFigure 3-5 shows a high-availability, dual-controller connection through

Page 43 - Controller A

48 HP 2012fc Modular Smart Array user guide • January 2013

Page 44

49CHAPTER4Configuring a System for the First TimeThis chapter describes how to perform first-time configuration on the storage system. It also describ

Page 45 - Data Host

Contents 5Logging in to SMU from a Local Management Host . . . . . . . . . . . . . . . . . . . . . . . . 54Updating Firmware . . . . . . . . . . . . .

Page 46 - Switches

50 HP 2012fc Modular Smart Array user guide • January 2013Setting Management Port IP Addresses Using the CLI Note – If you used DHCP to set the IP add

Page 47

Chapter 4 Configuring a System for the First Time 51Your package contents include a micro-DB9-to-DB9 serial cable. If necessary, use a DB9-to-DB25 ada

Page 48

52 HP 2012fc Modular Smart Array user guide • January 20134. In the terminal emulator, connect to controller A.5. Press Enter to display the CLI promp

Page 49

Chapter 4 Configuring a System for the First Time 539. In the host computer's command window, type the following command to verify Ethernet conne

Page 50

54 HP 2012fc Modular Smart Array user guide • January 2013Logging in to SMU from a Local Management HostTo log in to SMU from a local management host:

Page 51 - Parameter Value

Chapter 4 Configuring a System for the First Time 55 If a time server can provide local time rather than UT, configure the storage devices to use tha

Page 52 - ■ netmask is the subnet mask

56 HP 2012fc Modular Smart Array user guide • January 20132. In the Controller Module Host Port Configuration panels, for each port to which an HBA or

Page 53

Chapter 4 Configuring a System for the First Time 57Creating Virtual DisksTwo or more disk drives can be logically combined to form a virtual disk. Th

Page 54 - Setting the Date and Time

58 HP 2012fc Modular Smart Array user guide • January 2013Mapping a Data Host to a VolumeTo enable a data host to access a volume you created, you mus

Page 55 - Configuring Host Ports

Chapter 4 Configuring a System for the First Time 59Testing the ConfigurationTo determine that your system is ready for use, test the configuration as

Page 56

6 HP 2012fc Modular Smart Array user guide • January 2013

Page 57 - Creating Virtual Disks

60 HP 2012fc Modular Smart Array user guide • January 2013

Page 58

61APPENDIXAPowering the System Off and OnThis appendix describes how to power off and power on the system when needed.Powering Off the SystemThe syste

Page 59 - Logging Out of SMU

62 HP 2012fc Modular Smart Array user guide • January 20132. Press the power switches at the back of the controller enclosure to the On (–) position.I

Page 60

63APPENDIXBRegulatory Compliance and SafetyRegulatory ComplianceFederal Communications Commission NoticePart 15 of the Federal Communications Commissi

Page 61 - Powering On the System

64 HP 2012fc Modular Smart Array user guide • January 2013instructions, may cause harmful interference to radio communications. Operation of this equi

Page 62

Appendix B Regulatory Compliance and Safety 65To identify this product, refer to the part, Regulatory Model Number, or product number found on the pro

Page 63 - Regulatory Compliance

66 HP 2012fc Modular Smart Array user guide • January 2013Laser Safety WarningWarning – To reduce the risk of exposure to hazardous radiation: Do not

Page 64 - Class B Equipment

Appendix B Regulatory Compliance and Safety 67International Notices and StatementsCanadian Notice (avis Canadien)Class A EquipmentThis Class A digital

Page 65 - Laser Device

68 HP 2012fc Modular Smart Array user guide • January 2013 Also approved under UL 60950/CSA C22.2 No. 60950-00, Safety of Information Technology Equi

Page 66 - Laser Product Label

Appendix B Regulatory Compliance and Safety 69Korean NoticesSafetyBattery Replacement NoticeYour computer is equipped with a lithium manganese dioxide

Page 67 - European Union Notice

7About This GuideIntended AudienceThis guide is intended for use by system administrators and information professionals who are experienced with the f

Page 68 - Japanese Notice

70 HP 2012fc Modular Smart Array user guide • January 2013For more information about battery replacement or proper disposal, contact an HP authorized

Page 69 - Battery Replacement Notice

Appendix B Regulatory Compliance and Safety 71Japanese Power Cord NoticeElectrostatic DischargeTo prevent damage to the system, be aware of the precau

Page 70 - Power Cords

72 HP 2012fc Modular Smart Array user guide • January 2013Note – For more information on static electricity, or assistance with product installation,

Page 71 - Electrostatic Discharge

Appendix B Regulatory Compliance and Safety 73Dutch NoticeEnglish NoticeDisposal of waste equipment by users in private household in the European Unio

Page 72 - Danish Notice

74 HP 2012fc Modular Smart Array user guide • January 2013Estonian NoticeFinnish NoticeSeadmete jäätmete kõrvaldamine eramajapidamistes Euroopa Liidus

Page 73 - English Notice

Appendix B Regulatory Compliance and Safety 75French NoticeGerman NoticeÉlimination des appareils mis au rebut par les ménages dans l'Union europ

Page 74 - Finnish Notice

76 HP 2012fc Modular Smart Array user guide • January 2013Greek NoticeHungarian Notice. ,..,,.Készülékek magánháztartásban történ selejtezése az Euró

Page 75 - German Notice

Appendix B Regulatory Compliance and Safety 77Italian NoticeLatvian NoticeSmaltimento delle apparecchiature da parte di privati nel territorio dell&ap

Page 76 - Hungarian Notice

78 HP 2012fc Modular Smart Array user guide • January 2013Lihuanian NoticePolish NoticeNolietotu iek rtu izn cin šanas noteikumi lietot jiem Eiropas

Page 77 - Latvian Notice

Appendix B Regulatory Compliance and Safety 79Portuguese NoticeSlovakian NoticeDescarte de Lixo Elétrico na Comunidade Européia Este símbolo encontra

Page 78 - Polish Notice

8 HP 2012fc Modular Smart Array user guide • January 2013Document ConventionsRack StabilityCaution – To reduce the risk of personal injury or damage t

Page 79 - Slovakian Notice

80 HP 2012fc Modular Smart Array user guide • January 2013Slovenian NoticeSpanish NoticeEliminación de residuos de equipos eléctricos y electrónicos p

Page 80 - Spanish Notice

Appendix B Regulatory Compliance and Safety 81Swedish NoticeBortskaffande av avfallsprodukter från användare i privathushåll inom Europeiska Unionen

Page 81 - Swedish Notice

82 HP 2012fc Modular Smart Array user guide • January 2013

Page 82

83IndexAaccessingSMU,54the CLI,50accumulators,70Avis Canadien, regulatory compliancenotice,67Bbatteriesrecycling or disposal,70replacementnotice,69Tai

Page 83

84 HP 2012fc Modular Smart Array user guide • January 2013cord. See power cordcurrent rating,70Ddata hostsconnecting to controller enclosuresmapping

Page 84

Index 85IIEC EMC, worldwide regulatory compliance notice,67indicators, See LEDsinstalling enclosureschecklist,23in a rack,28safety precautions,26i

Page 85

86 HP 2012fc Modular Smart Array user guide • January 2013preparing,27recycling, battery,70recycling, Taiwan EPA battery,70regulatory complianceinfor

Page 86

Index 87using,71

Page 87 - Index 87

88 HP 2012fc Modular Smart Array user guide • January 2013

Page 88

About This Guide 9HP Technical SupportTelephone numbers for worldwide technical support are listed on the HP support website: http://www.hp.com/suppor