Power Cord Set Requirements
The monitor power supply is provided with automatic line switching (ALS). This feature allows the monitor to
operate on input voltages in the range of 100–240V, 50/60 Hz, 1.5A.
The power cord set (flexible cord or wall plug) received with the monitor meets the requirements for use in the
country/region where the equipment was purchased.
If you need to obtain a power cord for a different country/region, you should purchase a power cord that is
approved for use in that country/region.
The power cord must be rated for the product and for the voltage and current marked on the product’s electrical
ratings label. The voltage and current rating of the cord should be greater than the voltage and current rating
marked on the product. In addition, the cross-sectional area of the wire must be a minimum of 0.75 mm² or
18AWG, and the length of the cord must be between 4.94 ft (1.5 m) and 12 ft (3.6 m). If you have questions
about the type of power cord to use, contact your HP-authorized service provider.
A power cord should be routed so that it is not likely to be walked on or pinched by items placed upon it or
against it. Particular attention should be paid to the plug, electrical outlet, and the point where the cord exits from
the product.
Pin Assignments
Pin Number 15-Pin Side of
the Signal Cable
1 Video-Red
2 Video-Green
3 Video-Blue
4 Ground
5 Detect Cable
6 GND-R
7 GND-G
8 GND-B
9 +5V
10 Ground
11 Ground
12 DDC-Serial data
13 H-sync
14 V-sync
15 DDC-Serial clock