Enter/Exit Programming Mode 1D Symbologies
92
HP Retail Integrated Barcode Scanner
Code 128 Set Length 1
Specifies one of the barcode lengths for Code 128 Length Control. Length 1 is the minimum
label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode.
Length includes the barcode’s data characters only.
The length can be set from 1 to 50
characters.
Table 5 provides some examples for setting Length 1. See page 188 for detailed instructions
on setting this feature.
Table 5. Code 128 Length 1 Setting Examples
STEP ACTION EXAMPLES
1 Desired Setting
01 Character 07 Characters 15 Characters 50 Characters
2 Scan ENTER/EXIT PROGRAMMING MODE
3 Scan SELECT CODE 128 LENGTH 1 SETTING
4
Scan Two Characters From
Appendix D, Keypad
‘0’ and ‘1’ ‘0’ and ‘7’ ‘1’ and ‘5’ ‘5’ AND ‘0’
5 Scan ENTER/EXIT PROGRAMMING MODE
Select Code 128 Set Length 1 Setting
Make a mistake? Scan the CANCEL barcode to
abort and not save the entry string. You can then start
again at the beginning.
CANCEL
$CC8L1
~
DEFAULT
01 = Length 1 is 1 Character