HP dx5150 Informations techniques Page 141

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 182
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 140
Service Reference Guide, dx5150 361685-001 C–3
POST Error Messages
Memory test fail If POST detects an error
during memory testing,
additional information
appears giving specifics about
the type and location of the
memory error.
Shut down the system, reseat the DIMMs, and
reboot the system. If the problem persists,
replace the DIMMs.
Override enabled–
Defaults loaded
If the system cannot boot using
the current CMOS
configuration, the BIOS can
override the current
configuration with a set of
BIOS defaults designed for the
most stable, minimal-
performance system.
None.
Error: Non-System
disk or disk error.
Replace and press
any key when ready
The BIOS was unable to find a
suitable boot device. This may
mean an unitialized or corrupt
ATA flash.
Shut down the system, ensure that the power
and data cables of all storage devices are
plugged in properly, and reboot the system.
Ensure all removable media have been
removed.
Warning: CPU fan
has failed.
CPU fan weak (RPM < 1000)
or not turning.
Ensure that the CPU fan power cable is
connected. If the problem persists, replace the
fan.
Warning: System Fan
has failed.
System fan weak (RPM <
1000) or not turning.
Ensure that the System fan power cable is
connected. If the problem persists, replace the
fan.
Memory is running at
Single Channel Mode
When two same size
memories are put in slot 1 and
3, this message will be
displayed.
For optimal performance, shut down the system
and move the second DIMM from the XMM3 to
the XMM2 socket.
Numeric Codes and Text Messages (Continued)
Code/Message Probable Cause Recommended Action
Vue de la page 140