SDR EMS Messages
HP NonStop SQL DDL Replicator User’s Guide545799-007
B-13
Critical Messages
459
Cause. SDR encountered an error when using the IOEDIT routines to communicate
with EMSDIST.
Effect. SDR cannot monitor system events and will fail to replicate SQL DDL.
Recovery. This is an internal error. Contact product support.
460
Cause. The SDR monitor is down.
Effect. SDR cannot perform critical functions when the monitor is down.
Recovery. Use SDRCOM to start the SDR monitor.
461
Cause. SDR monitor was unable to contact the SDR updater.
Effect. Orderly SDR processing may be affected.
Recovery. Contact product support.
462
Cause. A processor failure caused a SDRUPDT process to terminate.
Effect. SDR updating is temporarily interrupted.
Recovery. No corrective action is needed. SDR will restart SDRUPDT in another
processor.
463
Cause. A backup node or communications failure has caused a SDRUPDT process to
terminate.
IOEdit error
SDR monitor down
SDR monitor cannot communicate with SDR updater
SDR updater CPU failure
SDR updater node failure