Hardware options installation 79
Power supply module
Power redundancy requires the presence of two power supply modules in the system.
CAUTION: All power supplies installed in the server must have the same output power capacity.
Verify that all power supplies have the same part number and label color. The system becomes
unstable and may shut down when it detects mismatched power supplies.
Label color Output
Blue
460 W
Orange
750 W
CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless
all bays are populated with either a component or a blank.
To install the component:
1. Access the product rear panel.
2. If necessary, remove the blank.
WARNING: To reduce the risk of personal injury from hot surfaces, allow the power supply or
power supply blank to cool before touching it.