Tests And Error Messages
MaxiLife Test Sequence And Error Messages
Chapter 4
80
Pre-boot Diagnostics Error Codes
When a failure occurs prior to the operating system loading, the workstation beeps three
times, then begins a series of beeps. These beeps identify the part that needs
troubleshooting or replacement.
Number of beeps Problem
1 Absent or incorrectly connected processor
2 Power supply is in protected mode
3 Memory modules not present, incompatible, or not functioning
4 Video controller failure
5 PnP/PCI initialization failure
6 Corrupted BIOS; you need to activate crisis-recovery procedure
7 System board failure