Installation and
Reference Guide
HP J2611B
HP AdvanceStack 10Base-T Hub-16U
Vue de la page 0
1 2 3 4 5 6 ... 69 70

Résumé du contenu

Page 1 - HP J2611B

Installation and Reference GuideHP J2611BHP AdvanceStack 10Base-T Hub-16U

Page 3 - HP Customer Support Services

Table of Contents1 Installing the HubInstallation Summary . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2Included

Page 4

Customer Support Services . . . . . . . . . . . . . . . . . . . . . . . 2-11HP BBS and World Wide Web . . . . . . .

Page 5 - HP AdvanceStack Hub-16U

1Installing the HubInstallation SummaryIncluded Parts1. Install Add-in Modules (Optional)2. Verify the Hub’s Operation3. Mount the Hub4. Complete

Page 6 - All Rights Reserved

Installation SummaryThe basic hardware installation procedure for the Hub-16U is as follows:1. Install the optional HP AdvanceStack 8U/16U SNMP Module

Page 7

1. Install add-in modules (optional)The Hub-16U can be custom-configured by installing an optional HPAdvanceStack 8U/16U SNMP Module or an HP Transce

Page 8 - Back of the Hub

The PC serves as a console that enables you to configure, monitor, andtroubleshoot the hub. For more information about the ASCII console commands, see

Page 9 - Features

HP Transceiver ModulesThe HP Transceiver Modules provide additional connectivity choices fromthe hub to Ethernet networks.The following optional trans

Page 10

2. Verify the hub’s operationTo provide power to the hub, follow these steps: 1. Plug the power cord into the hub’s power cord receptacle and into an

Page 11 - Table of Contents

2. Check the LEDs on the hub’s front panel.When the hub is powered on, it performs a self-diagnostic test.During the test, all of the hub LEDs are lit

Page 13 - Installing the Hub

3. Mount the hubThe HP AdvanceStack Hub-16U can be mounted in three ways:in a rack or cabineton a wallon a tableThe hardware for mounting the hub is

Page 14 - Included Parts

Rack or Cabinet MountingWarning The rack or cabinet should be adequately secured to prevent itfrom becoming unstable and/or falling over.1. Using a fl

Page 15

Wall Mounting1. Using a flat-headed or Torx T-10 screwdriver, attach the mountingbrackets to the hub with 10-mm M3 screws included in the accessorykit

Page 16 - ASCII console

4. Complete the network connectionsto the hubReconnect the hub to the power source and then make the networkconnections to the hub. With the hub moun

Page 17 - HP Transceiver Modules

Cable managementThe Hub-16U has been designed to help you with the problem of managingyour network cables. Each mounting bracket has a loop hole for a

Page 18 - Power receptacle

Connecting Hubs TogetherTwisted-Pair Cascade ConnectionsTo expand your network, the hub can be connected to other hubs by usingthe Media Dependent Int

Page 19

In the following illustration, the first hub is connected to two end nodes andto a second hub. ThinLAN ConnectionsWith an HP ThinLAN Transceiver Modul

Page 20 - 3. Mount the hub

You can connect up to 30 hubs together on a common ThinLAN segment.The ThinLAN segment can include a computer attached to a hub at one endof the segme

Page 21 - Rack or Cabinet Mounting

The following illustration shows a hub with an HP ThinLAN TransceiverModule connected to a thin LAN backbone.Connecting the Hub-16U to a Fiber-Optic B

Page 22 - Wall Mounting

2TroubleshootingTroubleshooting ApproachesDiagnosing with the LEDsInstallation ProblemsCabling ProblemsUnusual Network ActivityDiagnostic TestsReplace

Page 23 - Connecting Devices to the Hub

HP Customer Support ServicesHow to get the latest software/agent firmwareYou can download:HP AdvanceStack 8U/16U SNMP firmware: j3133a.exefrom the

Page 24 - Cable management

This chapter describes how to diagnose and resolve operating problems withyour hub.Additionally, if you have a HP AdvanceStack 8U/16U SNMP Module inst

Page 25 - Connecting Hubs Together

Diagnosing with the LEDsMost problems with the hub can be diagnosed using the LEDs on its frontpanel. This section describes the normal LED pattern du

Page 26

LED Error IndicationsLED patterns indicating problems Diagnostic TipsPower Collision AUI/XcvrPortTwisted-PairPortOFF * * *Verify that the power cord i

Page 27

LED patterns indicating problems Diagnostic TipsPower Collision AUI/XcvrPortTwisted-PairPortON Appearssolidly ON**Very frequent collisions are occurri

Page 28

Installation ProblemsBy carefully following the installation procedures described in chapter 1,“Installing the Hub”, you can avoid most problems cause

Page 29 - Troubleshooting

Non-standard CablesMis-wired cables may cause numerous network collisions, and can seriouslyimpair network performance. Before connecting cables into

Page 30 - Troubleshooting Approaches

connections. See the documentation shipped with the HP AdvanceStack8U/16U SNMP module and the software’s online Help system for moredetails about thes

Page 31 - Diagnosing with the LEDs

Testing End-to-End Network CommunicationsBoth the hub and the cabling can be tested by running an end-to-endcommunications test — a test that sends kn

Page 32 - LED Error Indications

Replacement InstructionsRemove any of the optional modules that you have installed into your hubbefore returning it to Hewlett-Packard. Keep the optio

Page 33

Customer Support ServicesHewlett-Packard offers support 24 hours a day, seven days a week throughthe use of automated electronic services including:He

Page 35 - Diagnostic Tests

Hewlett-Packard FTP Library ServiceTo access the HP FTP Library, follow these steps:1. Enter the command:ftp ftp-boi.external.hp.com The ftp> promp

Page 36 - Testing Twisted-Pair Cabling

CompuServeCompuServe is an electronic information and communication service run byan independent company. The service is typically accessed with a com

Page 37 - PC responding to

HP FIRST Fax Retrieval ServiceHP FIRST is an automated fax retrieval service that is available 24 hours aday, seven days a week. HP FIRST provides inf

Page 38 - Replacement Instructions

3Hub ReferenceFront of the HubBack of the HubHub Operation

Page 39 - Customer Support Services

Front of the HubHub status LEDsThe hub status LEDs indicate whether the hub is functioning properly. Forfurther details on error conditions indicated

Page 40

Port status LEDsThe following table provides LED port information. If an HP AdvanceStack8U/16U SNMP module is installed, additional LED states may be

Page 41 - CompuServe

Hub OperationThe HP AdvanceStack Hub-16U is a multiport repeater that conforms to theIEEE 802.3 repeater specification. Data signals coming into the h

Page 42

Auto-PartitioningThe hub will automatically partition (temporarily disable) one of its ports ifa collision condition exists for an excessive duration

Page 44 - Front of the Hub

ACables and ConnectorsRecommended CablesTwisted-Pair Cable/Connector Pin-OutsThinLAN Requirements

Page 45 - Back of the hub

HP AdvanceStack Hub-16UInstallation and Reference Guide

Page 46 - Hub Operation

This appendix lists cables that have been tested and verified for use with theHP AdvanceStack Hub-16U. It also includes minimum pin-out informationso

Page 47 - Link Beat

Twisted-Pair Cable/ConnectorPin-OutsTwisted-Pair Cable for Hub-to-ComputerNetwork ConnectionTo connect PCs or other network devices to the hub, use a

Page 48

Twisted-Pair Cable Pin AssignmentsTwisted-Pair Straight-Through CableHub End Computer orTransceiver EndSignalPins PinsSignal(receive +)(receive –)(tra

Page 49 - Cables and Connectors

BSpecificationsPhysicalElectricalEnvironmentalConnectorsElectromagnetic

Page 50 - Recommended Cables

PhysicalWidth: 42.5 cm (16.8 in)Height: 4.36 cm (1.7 in)Depth: 23.8 cm (9.4 in)Weight: 2.2 kg (4.8 lb)Electricalac voltage: 100 - 127 volts 200-24

Page 51 - Pin-Outs

Safety and Regulatory Statements

Page 52 - ThinLAN Cable Requirements

Safety InformationSafety SymbolsDocumentation reference symbol. If the product is marked with this symbol, refer tothe product documentation to get m

Page 53 - Specifications

Informations concernant la sécuritéSymboles de sécuritéSymbole de référence à la documentation. Si le produit est marquéde ce symbole, reportez-vous

Page 54

Hinweise zur SicherheitSicherheitssymboleSymbol für Dokumentationsverweis. Wenn das Produkt mit diesem Symbolmarkiert ist, schlagen Sie bitte in der P

Page 55

Considerazioni sulla sicurezzaSimboli di sicurezzaSimbolo di riferimento alla documentazione. Se il prodotto è contrassegnatoda questo simbolo, fare

Page 56 - Safety Information

©Copyright Hewlett-Packard Company 1996All Rights Reserved.DisclaimerReproduction, adaptation, or translation withoutprior written permission is prohi

Page 57 - Statements

Consideraciones sobre seguridadSímbolos de seguridadSímbolo de referencia a la documentación. Si el producto va marcadocon este símbolo, consultar la

Page 58 - Hinweise zur Sicherheit

Safety InformationSafety and RegulatoryStatements 7

Page 59 - Simboli di sicurezza

Regulatory StatementsFCC Statement (For U.S.A. Only)Federal Communications Commission Radio Frequency InterferenceStatementWarning: This equipment ge

Page 60 - Símbolos de seguridad

Declaration of ConformityThe following Declaration of Conformity for the HP AdvanceStack Hub-16Ucomplies with ISO/IEC Guide 22 and EN 45014. The decl

Page 63 - Declaration of Conformity

!50-ohm terminatorfor a ThinLAN cable segment ... 1-15AActivity LED ... 3-2AUI/Xcvr LED ... 3-3auto-partitioningbasic operation ... 3-5Bback of the hu

Page 64

hub operationauto-partitioning ... 3-5collision detection ... 3-4description ... 3-4link beat ... 3-5verifying ... 1-6hub to hub network connectionswi

Page 65

Rrack mountinginstructions for ... 1-9recommended cables ... A-2Regulatory statements ... C-8replacementof the hub ... 2-10resetting the hubtroublesho

Page 67

HP AdvanceStack Hub-16UAt A GlanceThe HP J2611B AdvanceStack Hub-16U is a multiport repeater with 16twisted-pair network ports. With this hub, you can

Page 68

Technical information in thisdocument is subject to changewithout notice.© Copyright 1996Hewlett-Packard CompanyPrinted in U.S.A. 2/96Manual Part Nu

Page 69

MDI/MDI-X switchfor port 16Hub statusLEDsTwisted-pairportsTwisted-pairport LEDsFront of the HubCover plate over slot for HP AUI andTransceiver Modules

Page 70 - *J2611-90101*

Features Network Connections 16 RJ-45 (twisted-pair) ports to connect to end nodes or other devices.A Media Dependent Interface (MDI) switch for Port