HP 4400 Dual Controller Enterprise Virtual Array Manuel d'utilisateur Page 92

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 139
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 91
Figure 38 VMware configuration
5. SAN switch 11. Network interconnection
6. SAN switch 22. Single HBA server (Host 1)
7. Controller A3. Dual HBA server (Host 2)
8. Controller B4. Management server
Mac OS configuration
For information about Mac OS connectivity, see Mac OS X Fibre Channel connectivity to the HP
Enterprise Virtual Array Storage System Configuration Guide (to download, see “Documents
(page 106)).
Failure scenarios
HP-UX
Failure effectFault stimulus
Extremely critical event on UNIX. Can cause loss of system disk.Server failure (host power-cycled)
Short term: Data transfer stops. Possible I/O errors.
Long term: Job hangs, cannot umount disk, fsck failed, disk corrupted,
need mkfs disk.
Switch failure (SAN switch disabled)
Short term: Data transfer stops. Possible I/O errors.
Long term: Job hangs, cannot umount disk, fsck failed, disk corrupted,
need mkfs disk.
Controller failure
Short term: Data transfer stops. Possible I/O errors.
Long term: Job hangs, cannot umount disk, fsck failed, disk corrupted,
need mkfs disk.
Controller restart
92 Single path implementation
Vue de la page 91
1 2 ... 87 88 89 90 91 92 93 94 95 96 97 ... 138 139

Commentaires sur ces manuels

Pas de commentaire