HP AB300 - Server Console Solution Guide de dépannage Page 54

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 88
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 53
4–30 335795-006 Troubleshooting Guide
Diagnostics and Troubleshooting
Diskless (No-Flash) Unit
Troubleshooting
This section is only for those units that do not have ATA Flash
capability.
Because there is no ATA Flash in this model the boot priority
sequence is:
USB device
PXE
1. When the unit boots, the monitor should display the
following information:
MAC Address — NIC portion of the system board is OK
GUID—General system board information
Client ID—Information from server
MASK—Information from server
DHCP IP—Information from server
If there is no MAC Address, the system board is at fault.
Contact the Call Center for service.
If there is not GUID information, the system board is at
fault and should be replaced.
If there is no Client ID, MASK, and DHCP IP
information there is no network connection. This may be
caused by a bad cable, the server is down, or a bad system
board. Contact the Call Center for service for the bad
system board.
If you are running in an MS RIS PXE environment go to
step 2.
If you are running in a Linux environment go to step 3.
Vue de la page 53
1 2 ... 49 50 51 52 53 54 55 56 57 58 59 ... 87 88

Commentaires sur ces manuels

Pas de commentaire