1.Hot-plug Disks4.Redundant Hot-swap Fans2.Cell Boards5.PCI Power Supplies3.Redundant Hot-swap Power6.Removable Media DVD/DATQuickSpecsHP 9000 rp8440
Viewing system statusEvent notification to system console, e mail, pager, and/or HP Response CentersAutomatic hardware protection of critical environm
Product NumberDisk CapacityRotational speedAverage seek time(read/write)Sustained BandwidthAD146A36 GB15,000 RPM3.6 msec (read); 3.9msec (write)40 MB/
Addition I/O resourcesusing the ServerExpansion Unit (SEU)Additional I/O resources can be obtained by adding the HP Server Expansion Unit 2 (SEU 2). T
All HP 9000 rx8620 servers are shipped with four AC power cords.AC Power ConsumptionThe HP 9000 rp8440 Server power consumption will vary greatly depe
3 bulk power supplies.Typical power consumption: 1870 VA (9.35 A @ 200 VAC across 2 cords)Power DistributionUnits60 amp Power Distribution UnitAF916A
PartitioningA hardware partition corresponds roughly to a single, standalone system. The HP 9000 rp8440Server can be subdivided into four partitions,
Number of HardPartitionsMinimum # of CellsMinimum Available I/OSlotsCore I/O (required)Minimum AvailableDisk/Media Bays1 PartitionAny one Cell8 12/12
recommended security patches.System Inventory Manager is for change and asset management. It enables you to easilycollect, store, and manage inventory
RackingThe HP 9000 rp8440 Server was designed to provide industry leading performance density andavailability when ordered in a racked configuration.
UPSManagement of local UPSs for the rx7640 and rp8440 is now through a LAN port on the core I/Ocard. Management of UPSs by the predecessor, rx7620 and
1.System Backplane4.Hot-swap Redundant Fans2.Core I/O5.Hot-plug PCI Slots3.2N Redundant Power Inputs HP 9000 rp8440 Server Flexible Advantage Starte
HP 9000 rp84xxUpgrades to HP 9000rp8440 ServersAll HP rp84xx servers are in box upgradeable to rp8440 servers in the current chassis. In boxupgrades m
Nameplates and labels"Read Me" documents, Upgrade Guide, CD ROMMiscellaneous cablesFor more information on upgrades, return credits and serv
Server model numberrp8440 Number of dual coreHP PA 8900 Processorcores2-32ChipsetHP sx2000Server productnumbersBaseA9958ANumber of dual coreHP PA 8900
Core I/OUltra320 SCSI-LVD11 GbE (RJ 45 connector)1RS 232 serial port (oneconsole)1100Base T port (LANconsole connection)1I/O Buses and SlotsTotal Hot-
Site PreparationSite planning andinstallation includedYesDepth (in/mm)30 in (762 mm)Width (in/mm)19 in (482 mm)Height (in/mm/EIA)Racked29.75 in (755 m
© Copyright 2008 Hewlett-Packard Development Company, L.P.The information contained herein is subject to change without notice.Intel and Itanium are r
Minimum SystemTwo HP PA RISC PA 8900 (1P/2C) processorsOne processor per cell board (Dual core PA 8900 requires one active core per cell board)One cel
High AvailabilityN+1 Hot swap coolingRedundant and hot swap power suppliesCell Hot plugHot plug disks2N power inputsOn line memory page deallocationEC
ConfigurationThe HP 9000 rp8440 Server is a symmetrical multiprocessing (SMP) server supporting up to 16high performance dual core HP PA RISC PA 8900
Memory ConfigurationThe memory DIMMs used in the HP 9000 rp8440 Server are sold in pairs and are customdesigned by HP. Each DIMM contains DDR II memor
Performance TuningGuidelinesFor best performance, a cell should be configured with a multiple of 8 DIMMs or four pairs(although the server will execut
PCI BackplaneEight of sixteen I/O card slots are supported by dual high performance fat links. Each link iscapable of providing 1060 MB/s of bandwidth
PCI-X 2 port 4GB FC, 2 Port 1000Base-TAD194A11i v1/yesLC (SFF) /RJ-45Yes / No16 / 32PCI-X 2 GB Fibre Channel, 1000Base-SXA9782A11i/YesLC (SFF)/LCGigEY
Commentaires sur ces manuels