HP NonStop S-Series
Hardware Installation
and FastPath Guide
Abstract
This guide is written for anyone qualified to install an HP NonStop™ S-series server.
This guide describes how to install and start a NonStop S-series server for the first
time. It includes information about installing server hardware, cabling system
enclosures, installing and starting NonStop system consoles, installing external system
devices, starting the server, and configuring the server after startup. This guide also
provides overview information about the I/O adapter module (IOAM) enclosure. A
quick reference to installing and configuring a two-processor or four-processor
NonStop S-series server in the Tetra 8 topology is included.
Product Version
N.A.
Supported Release Version Updates (RVUs)
This publication supports G06.28 and all subsequent G-series RVUs until otherwise
indicated by its replacement publication.
Part Number Published
541880-001 February 2006
Vue de la page 0
1 2 3 4 5 6 ... 483 484

Résumé du contenu

Page 1 - Hardware Installation

HP NonStop S-Series Hardware Installation and FastPath GuideAbstractThis guide is written for anyone qualified to install an HP NonStop™ S-series serv

Page 2 - Document History

ContentsHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001viii14. Case Study: Installing and Configuring aSystem (continued)14.

Page 3 - FastPath Guide

Installing EnclosuresHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0012-12Unpack the Enclosures16. With a 3/4-inch (19-mm) or a

Page 4 - 2. Installing Enclosures

Installing EnclosuresHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0012-13Connect the GroundstrapsConnect the Groundstraps For i

Page 5 - 3. Cabling Enclosures

Installing EnclosuresHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0012-14Connect the Groundstrapsc. Install the other end of th

Page 6

Installing EnclosuresHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0012-15Connect the GroundstrapsFigure 2-12. Examples of Groun

Page 7 - 10. Configuring the System

Installing EnclosuresHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0012-16Inventory the EnclosuresInventory the EnclosuresVerify

Page 8

Installing EnclosuresHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0012-17Slot Assignments for NonStop S-Series EnclosuresTable

Page 9 - Files (continued)

Installing EnclosuresHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0012-18Slot Assignments for NonStop S-Series EnclosuresFigure

Page 10 - A. Part Numbers

Installing EnclosuresHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0012-19Slot Assignments for NonStop S-Series EnclosuresFigure

Page 11 - D. Troubleshooting

Installing EnclosuresHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0012-20Slot Assignments for NonStop S-Series EnclosuresFigure

Page 12 - Contents

Installing EnclosuresHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0012-21Slot Assignments for NonStop S-Series Enclosures1. Ope

Page 13 - E. FastPath Tasks: Required

ContentsHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001ixB. ServerNet CablingB. ServerNet Cabling What ServerNet Cabling Diagr

Page 14 - Glossary

Installing EnclosuresHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0012-22Slot Assignments for NonStop S-Series Enclosures2. Ver

Page 15 - Examples

Installing EnclosuresHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0012-23Inspect the ComponentsInspect the ComponentsVibration

Page 16 - Figures (continued)

Installing EnclosuresHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0012-24Inspect the Componentsc. Reinsert the disk drive and s

Page 17

Installing EnclosuresHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0012-25Inspect the Componentsd. Reinsert the PMF CRU or IOMF

Page 18

Installing EnclosuresHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0012-26Inspect the Componentsa. Check that the ejectors on ea

Page 19

HP NonStop S-Series Hardware Installation and FastPath Guide—541880-0013-13 Cabling EnclosuresThis section explains how to cable enclosures in NonStop

Page 20 - Tables (continued)

Cabling EnclosuresHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0013-21. Connect Power-On Cables2. Insert the RJ-11 plug on one

Page 21 - What’s New in This Guide

Cabling EnclosuresHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0013-31. Connect Power-On CablesFigure 3-1. Connecting and Secur

Page 22 - New and Changed Information

Cabling EnclosuresHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0013-42. Connect EPO Cables2. Connect EPO Cables 1. Connect the

Page 23 - About This Guide

Cabling EnclosuresHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0013-53. Connect ServerNet Cables3. Connect ServerNet Cables1. P

Page 24 - What’s in This Guide

ContentsHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001xD. Troubleshooting (continued)D. Troubleshooting (continued)Starting

Page 25

Cabling EnclosuresHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0013-63. Connect ServerNet Cables2. Connect and route the Server

Page 26 - Where to Get More Information

HP NonStop S-Series Hardware Installation and FastPath Guide—541880-0014-14 Installing Service-Side DoorsThis section describes how to install optiona

Page 27

Installing Service-Side DoorsHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0014-26. Using four M5 Phillips screws and four M5 KE

Page 28 - Notation Conventions

Installing Service-Side DoorsHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0014-3c. Pull the Phillips screwdriver back out throu

Page 29 - Change Bar Notation

Installing Service-Side DoorsHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0014-4Figure 4-4 shows a system enclosure with a serv

Page 30

HP NonStop S-Series Hardware Installation and FastPath Guide—541880-0015-15Installing, Starting, and Testing a System ConsoleThis section describes ho

Page 31 - 1 Introduction

Installing, Starting, and Testing a System ConsoleHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0015-2Unpacking and Assembling a

Page 32 - Installation Overview

Installing, Starting, and Testing a System ConsoleHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0015-3Unpacking the System Conso

Page 33

Installing, Starting, and Testing a System ConsoleHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0015-4Unpacking the System Conso

Page 34

Installing, Starting, and Testing a System ConsoleHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0015-5Unpacking the System Conso

Page 35 - Standard Operating Practices

ContentsHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001xiE. FastPath Tasks: RequiredE. FastPath Tasks: Required1. Install Hard

Page 36 - Using ESD Protection

Installing, Starting, and Testing a System ConsoleHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0015-6Assembling the System Cons

Page 37

Installing, Starting, and Testing a System ConsoleHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0015-7Assembling the System Cons

Page 38 - Installation Checklist

Installing, Starting, and Testing a System ConsoleHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0015-8Starting and Testing a Sys

Page 39 - Shipping Packages

Installing, Starting, and Testing a System ConsoleHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0015-9Verifying ReadinessVerifyi

Page 40

Installing, Starting, and Testing a System ConsoleHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0015-10Operational Consideration

Page 41

Installing, Starting, and Testing a System ConsoleHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0015-11Connecting Multiple Syste

Page 42 - Enclosure Types

Installing, Starting, and Testing a System ConsoleHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0015-12System Console Function K

Page 43 - IOAM Enclosures

HP NonStop S-Series Hardware Installation and FastPath Guide—541880-0016-16 Connecting a System ConsoleThis section describes how to connect a primary

Page 44 - Related Components

Connecting a System ConsoleHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0016-2The Dedicated Service LANThe Dedicated Service LA

Page 45

Connecting a System ConsoleHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0016-3System Console Connection to a Dedicated ServiceL

Page 46 - Enclosure Illustrations

ContentsHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001xiiF. FastPath Tasks: OptionalF. FastPath Tasks: Optional1. Prerequisit

Page 47

Connecting a System ConsoleHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0016-4System Console Connection to a Secure OperationsL

Page 48

Connecting a System ConsoleHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0016-5Installing the Ethernet Switch or HubFor the part

Page 49

Connecting a System ConsoleHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0016-6Connect the System Console to the Ethernet Switch

Page 50

HP NonStop S-Series Hardware Installation and FastPath Guide—541880-0017-17Installing External System DevicesThis section describes how to install sel

Page 51

Installing External System DevicesHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0017-2Installing a 5175 Open-Reel Tape Subsystem

Page 52

Installing External System DevicesHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0017-3Installing a 5175 Open-Reel Tape Subsystem

Page 53 - Groundstraps

Installing External System DevicesHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0017-4Installing a 5175 Open-Reel Tape Subsystem

Page 54 - Power-On Cables

Installing External System DevicesHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0017-5Installing a 5175 Open-Reel Tape Subsystem

Page 55 - Emergency Power-Off Cables

Installing External System DevicesHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0017-6Installing a 5175 Open-Reel Tape Subsystem

Page 56 - System Organization

Installing External System DevicesHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0017-7Installing a 5175 Open-Reel Tape Subsystem

Page 57

ContentsHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001xiiiExamplesExamplesExample D-1. SCF STATUS LINE, DETAIL Display D-22Ex

Page 58

Installing External System DevicesHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0017-8Installing a 519x Cartridge Tape Subsystem

Page 59 - Enclosure

Installing External System DevicesHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0017-9Installing a 519x Cartridge Tape Subsystem

Page 60

Installing External System DevicesHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0017-10Installing a 519x Cartridge Tape Subsyste

Page 61 - Server Numbering and Labeling

Installing External System DevicesHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0017-11Installing a 519x Cartridge Tape Subsyste

Page 62 - Group ID Switches

Installing External System DevicesHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0017-12Installing Other Tape DevicesInstalling O

Page 63 - Identification Labels

Installing External System DevicesHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0017-13Installing Other Tape Devices9840 (CT9840

Page 64

Installing External System DevicesHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0017-14Installing Other Tape DevicesIf this docu

Page 65

Installing External System DevicesHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0017-15Installing Fibre Channel Tape Devices Usi

Page 66 - Fabrics and Slots

Installing External System DevicesHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0017-16Installing a SWAN or SWAN 2 Concentrator•

Page 67 - Cable Compatibilities

Installing External System DevicesHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0017-17Installing an AWAN ServerInstalling an AW

Page 68

ContentsHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001xivFigures (continued)Figures (continued)Figure 2-5. Removing End Piece

Page 69

Installing External System DevicesHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0017-18Installing Printers and TerminalsConfigur

Page 70 - Types of ServerNet Cables

HP NonStop S-Series Hardware Installation and FastPath Guide—541880-0018-18Powering On and Starting the SystemThis section describes how to power on N

Page 71 - Fiber-Optic Cables

Powering On and Starting the SystemHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0018-2Starting a System for the First TimeStart

Page 72 - Cable Lengths

Powering On and Starting the SystemHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0018-3Powering On External System Devices7. Con

Page 73 - Cable Routing

Powering On and Starting the SystemHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0018-4Powering On the Tape Subsystem6. Close th

Page 74

Powering On and Starting the SystemHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0018-5Powering On the System5. Close the rear b

Page 75 - The System Console

Powering On and Starting the SystemHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0018-6Power-On Procedure Using AC Power CordsPo

Page 76 - The TSM Package

Powering On and Starting the SystemHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0018-7Power-On Procedure Using AC Power Cords•F

Page 77

Powering On and Starting the SystemHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0018-8Power-On Procedure Using AC Power Cords2.

Page 78 - Dial-Outs

Powering On and Starting the SystemHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0018-9Power-On Procedure Using AC Power Cords3.

Page 79 - Dial-Ins

ContentsHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001xvFigures (continued)Figures (continued)Figure 8-2. AC Power Switch for

Page 80

Powering On and Starting the SystemHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0018-10Status LEDs During a Power-On Procedureg

Page 81

Powering On and Starting the SystemHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0018-11Status LEDs During a Power-On ProcedureS

Page 82 - Preconfigured IP Addresses

Powering On and Starting the SystemHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0018-12Troubleshooting Abnormal LED StatesTroub

Page 83

Powering On and Starting the SystemHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0018-13Troubleshooting Abnormal LED StatesIOMF

Page 84 - Software Connections

Powering On and Starting the SystemHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0018-14Verifying Topology and System Components

Page 85 - System Startup

Powering On and Starting the SystemHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0018-15Verifying Topology and System Components

Page 86 - VST956.vsd

Powering On and Starting the SystemHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0018-16Verifying Topology and System Components

Page 87 - System Load Path Test

Powering On and Starting the SystemHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0018-17Verifying Topology and System Components

Page 88

Powering On and Starting the SystemHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0018-18Starting the SystemStarting the SystemSt

Page 89 - 2 Installing Enclosures

Powering On and Starting the SystemHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0018-19Loading the System3. In the System Start

Page 90

ContentsHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001xviFigures (continued)Figures (continued)Figure C-1. Power-On Cabling:

Page 91 - 2. Prepare the Work Space

Powering On and Starting the SystemHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0018-20Loading the SystemIf one or more of the

Page 92 - 3. Organize the Equipment

Powering On and Starting the SystemHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0018-21Completing the System LoadCompleting the

Page 93 - VST977.vsd

Powering On and Starting the SystemHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0018-22Verifying the System Is Startedc. Close

Page 94 - Unpack the Enclosures

HP NonStop S-Series Hardware Installation and FastPath Guide—541880-0019-19 Performing Post-Startup Tasks This section describes the tasks that you mu

Page 95

Performing Post-Startup TasksHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0019-2Check Power SuppliesCheck Power SuppliesEnsure

Page 96 - End Piece

Performing Post-Startup TasksHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0019-3Check System Enclosure ComponentsFigure 9-1. Ma

Page 97 - System Enclosure on Pallet

Performing Post-Startup TasksHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0019-4Check System Enclosure Components5. In the view

Page 98 - CasterCaster

Performing Post-Startup TasksHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0019-5Check System Enclosure Components6. In the view

Page 99

Performing Post-Startup TasksHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0019-6Check Critical System Processes10. In the view

Page 100 - VST017.vsd

Performing Post-Startup TasksHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0019-7Check Disk Subsystem Status4. Verify that the L

Page 101 - Connect the Groundstraps

ContentsHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001xviiFigures (continued)Figures (continued)Figure E-12. Power-On Cables:

Page 102 - VST953.vsd

Performing Post-Startup TasksHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0019-8Test the Disk DrivesTest the Disk DrivesYou sho

Page 103 - VST976.vsd

Performing Post-Startup TasksHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0019-9Test the Disk DrivesThe following example shows

Page 104 - Inventory the Enclosures

Performing Post-Startup TasksHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0019-10Test the Communications Linesg. Return the pre

Page 105 - VST622.vsd

Performing Post-Startup TasksHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0019-11Check Tape Subsystem StatusCheck Tape Subsyste

Page 106 - Installing Enclosures

Performing Post-Startup TasksHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0019-12Completing Final Installation Steps•The BACKUP

Page 107

Performing Post-Startup TasksHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0019-13System Configuration Changes and Verifications

Page 108

Performing Post-Startup TasksHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0019-14Restarting the Inspect Monitor ProcessRestarti

Page 109

Performing Post-Startup TasksHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0019-15Preparing for Daily OperationsPreparing for Da

Page 110 - VST553.vsd

Performing Post-Startup TasksHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0019-16Configuring the OSM or TSM EnvironmentConfigur

Page 111 - Inspect the Components

HP NonStop S-Series Hardware Installation and FastPath Guide—541880-00110-110 Configuring the SystemThis section describes how to configure system con

Page 112 - VST965.vsd

Document History Part Number Product Version Published528858-001 N.A. September 2004529443-001 N.A. December 2004529876-001 N.A. April 2005540460-001

Page 113 - VST538.vsd

ContentsHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001xviiiTables (continued)Tables (continued)Table B-12. Tetra 8 Cabling: T

Page 114 - VST960.vsd

Configuring the SystemHP NonStop S-Series Hardware Installation and FastPath Guide—541880-00110-2Setup ConfigurationProfessional operating system, see

Page 115 - 3 Cabling Enclosures

Configuring the SystemHP NonStop S-Series Hardware Installation and FastPath Guide—541880-00110-3Operating ConfigurationDo not use the setup configura

Page 116 - 1. Connect Power-On Cables

Configuring the SystemHP NonStop S-Series Hardware Installation and FastPath Guide—541880-00110-4Create the Operating Configuration1. If the backup sy

Page 117 - VST021.vsd

Configuring the SystemHP NonStop S-Series Hardware Installation and FastPath Guide—541880-00110-5Create the Operating ConfigurationTo maintain EMC com

Page 118 - 2. Connect EPO Cables

Configuring the SystemHP NonStop S-Series Hardware Installation and FastPath Guide—541880-00110-6Add a System Console to the OperatingConfiguration6.

Page 119 - 3. Connect ServerNet Cables

Configuring the SystemHP NonStop S-Series Hardware Installation and FastPath Guide—541880-00110-7Add a System Console to the OperatingConfigurationBef

Page 120 - VST966.vsd

Configuring the SystemHP NonStop S-Series Hardware Installation and FastPath Guide—541880-00110-8Add a Server to the Operating Configuration5. Connect

Page 121 - Installing Service-Side Doors

Configuring the SystemHP NonStop S-Series Hardware Installation and FastPath Guide—541880-00110-9Add a Server to the Operating Configuration•Because a

Page 122 - VST095.vsd

Configuring the SystemHP NonStop S-Series Hardware Installation and FastPath Guide—541880-00110-10Create a Cascading Ethernet Switch Configuration5. C

Page 123 - VST096.vsd

Configuring the SystemHP NonStop S-Series Hardware Installation and FastPath Guide—541880-00110-11Create a Cascading Ethernet Switch ConfigurationProc

Page 124 - Group ID Label

HP NonStop S-Series Hardware Installation and FastPath Guide—541880-001xixWhat’s New in This GuideManual InformationHP NonStop S-Series Hardware Insta

Page 125 - System Console

Configuring the SystemHP NonStop S-Series Hardware Installation and FastPath Guide—541880-00110-12Add a System Console to the Cascading EthernetSwitch

Page 126 - Unpacking the System Console

Configuring the SystemHP NonStop S-Series Hardware Installation and FastPath Guide—541880-00110-13Unattended Site ConfigurationUnattended Site Configu

Page 127

Configuring the SystemHP NonStop S-Series Hardware Installation and FastPath Guide—541880-00110-14Add a Server to an Unattended Site ConfigurationProc

Page 128 - Unpack the PC Accessory Box

Configuring the SystemHP NonStop S-Series Hardware Installation and FastPath Guide—541880-00110-15Secure Operations LAN ConfigurationSecure Operations

Page 129 - Final Unpacking Steps

Configuring the SystemHP NonStop S-Series Hardware Installation and FastPath Guide—541880-00110-16Construct a Secure Operations LAN Configuration Figu

Page 130 - Assembling the System Console

Configuring the SystemHP NonStop S-Series Hardware Installation and FastPath Guide—541880-00110-17Construct a Secure Operations LAN ConfigurationProce

Page 131 - Connect the Modem

Configuring the SystemHP NonStop S-Series Hardware Installation and FastPath Guide—541880-00110-18Construct a Secure Operations LAN ConfigurationFor T

Page 132 - Powering On a System Console

HP NonStop S-Series Hardware Installation and FastPath Guide—541880-00111-111 Offline Configuration TasksThis section describes offline configuration

Page 133 - Restart the System Console

Offline Configuration TasksHP NonStop S-Series Hardware Installation and FastPath Guide—541880-00111-2Application ReconfigurationApplication Reconfigu

Page 134 - System Recovery (ASR) Disk

Offline Configuration TasksHP NonStop S-Series Hardware Installation and FastPath Guide—541880-00111-3Changing System Name, System Number, or TimeAttr

Page 135 - VST992.vsd

What’s New in This GuideHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001xxNew and Changed InformationNew and Changed Informatio

Page 136 - System Console Function Keys

Offline Configuration TasksHP NonStop S-Series Hardware Installation and FastPath Guide—541880-00111-4Changing the CONFTEXT File

Page 137 - 6 Connecting a System Console

HP NonStop S-Series Hardware Installation and FastPath Guide—541880-00112-112 Online Configuration TasksThis section describes how to configure your s

Page 138 - The Dedicated Service LAN

Online Configuration TasksHP NonStop S-Series Hardware Installation and FastPath Guide—541880-00112-2SCFSCFThe Subsystem Control Facility (SCF) config

Page 139 - Ethernet Port

Online Configuration TasksHP NonStop S-Series Hardware Installation and FastPath Guide—541880-00112-3Subsystems in G-Series RVUsSubsystems in G-Series

Page 140 - Installing Ferrite Cores

Online Configuration TasksHP NonStop S-Series Hardware Installation and FastPath Guide—541880-00112-4Generic ProcessesEach subsystem manager or monito

Page 141 - Connecting a System Console

Online Configuration TasksHP NonStop S-Series Hardware Installation and FastPath Guide—541880-00112-5Making Important Processes PersistentMaking Impor

Page 142

Online Configuration TasksHP NonStop S-Series Hardware Installation and FastPath Guide—541880-00112-6Types of System Configuration FilesTypes of Syste

Page 143 - Installing Tape Drives

Online Configuration TasksHP NonStop S-Series Hardware Installation and FastPath Guide—541880-00112-7Types of System Configuration Files This figure i

Page 144 - VST544.vsd

Online Configuration TasksHP NonStop S-Series Hardware Installation and FastPath Guide—541880-00112-8KMSFKMSFKernel-managed swap space manages virtual

Page 145 - Buffer board 6.80

Online Configuration TasksHP NonStop S-Series Hardware Installation and FastPath Guide—541880-00112-9The OSM and TSM PackagesThe OSM and TSM PackagesT

Page 146

HP NonStop S-Series Hardware Installation and FastPath Guide—541880-001xxiAbout This GuideThis guide describes how to install and bring up a NonStop S

Page 147 - Shipping Restraint

Online Configuration TasksHP NonStop S-Series Hardware Installation and FastPath Guide—541880-00112-10Creating an Alternate System DiskCreating an Alt

Page 148 - (4 places)

Online Configuration TasksHP NonStop S-Series Hardware Installation and FastPath Guide—541880-00112-111. Choose the Target Disk and Plan Its Space and

Page 149 - VST961.vsd

Online Configuration TasksHP NonStop S-Series Hardware Installation and FastPath Guide—541880-00112-122. Verify That the Target Disk Is Present2. Veri

Page 150 - Rear of 5175 Tape Drive CRU

Online Configuration TasksHP NonStop S-Series Hardware Installation and FastPath Guide—541880-00112-134. Change the Label of the Target Disk4. Change

Page 151 - VST556.vsd

Online Configuration TasksHP NonStop S-Series Hardware Installation and FastPath Guide—541880-00112-145. Create a New System Volume and a SystemImage

Page 152 - VST558.vsd

Online Configuration TasksHP NonStop S-Series Hardware Installation and FastPath Guide—541880-00112-157. Verify the Installation of Boot Millicode on

Page 153

Online Configuration TasksHP NonStop S-Series Hardware Installation and FastPath Guide—541880-00112-168. Copy Subvolumes to the Target Disk8. Copy Sub

Page 154 - Installing Other Tape Devices

Online Configuration TasksHP NonStop S-Series Hardware Installation and FastPath Guide—541880-00112-17Create a Command FileCreate a Command FileA comm

Page 155

Online Configuration TasksHP NonStop S-Series Hardware Installation and FastPath Guide—541880-00112-18Create a Command File4. Edit this log file to cr

Page 156

HP NonStop S-Series Hardware Installation and FastPath Guide—541880-00113-113Creating Startup and Shutdown FilesThis section describes command files t

Page 157 - IOAM Enclosure

About This GuideHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001xxiiWhat’s in This Guide4 Installing Service-Side DoorsThis sec

Page 158

Creating Startup and Shutdown FilesHP NonStop S-Series Hardware Installation and FastPath Guide—541880-00113-2Automating System Startup and ShutdownAu

Page 159 - Installing an AWAN Server

Creating Startup and Shutdown FilesHP NonStop S-Series Hardware Installation and FastPath Guide—541880-00113-3Processes That Represent the System Cons

Page 160

Creating Startup and Shutdown FilesHP NonStop S-Series Hardware Installation and FastPath Guide—541880-00113-4$ZHOME Alternative•Because $ZHOME acts a

Page 161 - Powering On and Starting the

Creating Startup and Shutdown FilesHP NonStop S-Series Hardware Installation and FastPath Guide—541880-00113-5Example Command FilesExample Command Fil

Page 162 - Startup Checklist

Creating Startup and Shutdown FilesHP NonStop S-Series Hardware Installation and FastPath Guide—541880-00113-6CIIN FileCIIN FileThe CIIN file contains

Page 163 - Procedure Page

Creating Startup and Shutdown FilesHP NonStop S-Series Hardware Installation and FastPath Guide—541880-00113-7Modifying a CIIN FileModifying a CIIN Fi

Page 164 - VST533.vsd

Creating Startup and Shutdown FilesHP NonStop S-Series Hardware Installation and FastPath Guide—541880-00113-8Example CIIN FilesExample CIIN FilesThis

Page 165 - VST051.vsd

Creating Startup and Shutdown FilesHP NonStop S-Series Hardware Installation and FastPath Guide—541880-00113-9Tips for Startup FilesComment -- for the

Page 166 - VST982.vsd

Creating Startup and Shutdown FilesHP NonStop S-Series Hardware Installation and FastPath Guide—541880-00113-10Startup File ExamplesStartup File Examp

Page 167 - VST708.vsd

Creating Startup and Shutdown FilesHP NonStop S-Series Hardware Installation and FastPath Guide—541880-00113-11System Startup FileComment -- If you ha

Page 168 - VST983.vsd

About This GuideHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001xxiiiWhat’s in This GuideD Troubleshooting This appendix explai

Page 169

Creating Startup and Shutdown FilesHP NonStop S-Series Hardware Installation and FastPath Guide—541880-00113-12Spooler Warm-Start FileSpooler Warm-Sta

Page 170

Creating Startup and Shutdown FilesHP NonStop S-Series Hardware Installation and FastPath Guide—541880-00113-13TCP/IP Stack Configuration and Startup

Page 171

Creating Startup and Shutdown FilesHP NonStop S-Series Hardware Installation and FastPath Guide—541880-00113-14TCP/IP Stack Configuration and Startup

Page 172

Creating Startup and Shutdown FilesHP NonStop S-Series Hardware Installation and FastPath Guide—541880-00113-15CP6100 Lines Startup FileCP6100 Lines S

Page 173

Creating Startup and Shutdown FilesHP NonStop S-Series Hardware Installation and FastPath Guide—541880-00113-16Printer Line Startup FilePrinter Line S

Page 174

Creating Startup and Shutdown FilesHP NonStop S-Series Hardware Installation and FastPath Guide—541880-00113-17Tips for Shutdown FilesTips for Shutdow

Page 175 - VST001.vsd

Creating Startup and Shutdown FilesHP NonStop S-Series Hardware Installation and FastPath Guide—541880-00113-18System Shutdown FileSystem Shutdown Fil

Page 176 - : click the power supply

Creating Startup and Shutdown FilesHP NonStop S-Series Hardware Installation and FastPath Guide—541880-00113-19CP6100 Lines Shutdown FileCP6100 Lines

Page 177

Creating Startup and Shutdown FilesHP NonStop S-Series Hardware Installation and FastPath Guide—541880-00113-20Printer Line Shutdown FilePrinter Line

Page 178 - Starting the System

Creating Startup and Shutdown FilesHP NonStop S-Series Hardware Installation and FastPath Guide—541880-00113-21Spooler Shutdown FileSpooler Shutdown F

Page 179 - VST591.vsd

About This GuideHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001xxivWhere to Get More InformationWhere to Get More InformationD

Page 180 - Loading the System

Creating Startup and Shutdown FilesHP NonStop S-Series Hardware Installation and FastPath Guide—541880-00113-22Adding Super-Group User IDs

Page 181 - Completing the System Load

HP NonStop S-Series Hardware Installation and FastPath Guide—541880-00114-114Case Study: Installing and Configuring a SystemThis section documents the

Page 182 - VST008.vsd

Case Study: Installing and Configuring a SystemHP NonStop S-Series Hardware Installation and FastPath Guide—541880-00114-2About These ExamplesAbout Th

Page 183 - Testing the System

Case Study: Installing and Configuring a SystemHP NonStop S-Series Hardware Installation and FastPath Guide—541880-00114-3Background for Developers In

Page 184 - Check Power Supplies

Case Study: Installing and Configuring a SystemHP NonStop S-Series Hardware Installation and FastPath Guide—541880-00114-4Hardware ConfigurationHardwa

Page 185 - VST007.vsd

Case Study: Installing and Configuring a SystemHP NonStop S-Series Hardware Installation and FastPath Guide—541880-00114-5Case Study: Installation Doc

Page 186 - VST002.vsd

Case Study: Installing and Configuring a SystemHP NonStop S-Series Hardware Installation and FastPath Guide—541880-00114-6Case Study: System Equipment

Page 187 - Performing Post-Startup Tasks

Case Study: Installing and Configuring a SystemHP NonStop S-Series Hardware Installation and FastPath Guide—541880-00114-7Case Study: Enclosure Arrang

Page 188

Case Study: Installing and Configuring a SystemHP NonStop S-Series Hardware Installation and FastPath Guide—541880-00114-8Case Study: Floor PlanCase S

Page 189 - Check Disk Subsystem Status

Case Study: Installing and Configuring a SystemHP NonStop S-Series Hardware Installation and FastPath Guide—541880-00114-9Case Study: Preinstalled I/O

Page 190 - Test the Disk Drives

About This GuideHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001xxvTSM Guided Replacement ProceduresTSM Guided Replacement Proc

Page 191

Case Study: Installing and Configuring a SystemHP NonStop S-Series Hardware Installation and FastPath Guide—541880-00114-10Case Study: Group 01 System

Page 192 - Test the Communications Lines

Case Study: Installing and Configuring a SystemHP NonStop S-Series Hardware Installation and FastPath Guide—541880-00114-11Case Study: Group 01 Slot 5

Page 193 - Check Tape Subsystem Status

Case Study: Installing and Configuring a SystemHP NonStop S-Series Hardware Installation and FastPath Guide—541880-00114-12Case Study: Group 01 Slot 5

Page 194

Case Study: Installing and Configuring a SystemHP NonStop S-Series Hardware Installation and FastPath Guide—541880-00114-13Case Study: Group 01 Slot 5

Page 195

Case Study: Installing and Configuring a SystemHP NonStop S-Series Hardware Installation and FastPath Guide—541880-00114-14Case Study: Group 01 Slot 5

Page 196

Case Study: Installing and Configuring a SystemHP NonStop S-Series Hardware Installation and FastPath Guide—541880-00114-15Case Study: Group 02 System

Page 197 - Reference Manuals

Case Study: Installing and Configuring a SystemHP NonStop S-Series Hardware Installation and FastPath Guide—541880-00114-16Case Study: Group 02 Slot 5

Page 198

Case Study: Installing and Configuring a SystemHP NonStop S-Series Hardware Installation and FastPath Guide—541880-00114-17Case Study: Group 02 Slot 5

Page 199 - 10 Configuring the System

Case Study: Installing and Configuring a SystemHP NonStop S-Series Hardware Installation and FastPath Guide—541880-00114-18Case Study: Group 02 Slot 5

Page 200 - Setup Configuration

Case Study: Installing and Configuring a SystemHP NonStop S-Series Hardware Installation and FastPath Guide—541880-00114-19Case Study: Group 02 Slot 5

Page 201 - Operating Configuration

About This GuideHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001xxviNotation ConventionsNotation ConventionsHypertext LinksBlue

Page 202 - Default Gateway 192.231.36.9

Case Study: Installing and Configuring a SystemHP NonStop S-Series Hardware Installation and FastPath Guide—541880-00114-20System Configuration: CONFT

Page 203 - Configuring the System

Case Study: Installing and Configuring a SystemHP NonStop S-Series Hardware Installation and FastPath Guide—541880-00114-21Registry of IP AddressesReg

Page 204 - VST065.vsd

Case Study: Installing and Configuring a SystemHP NonStop S-Series Hardware Installation and FastPath Guide—541880-00114-22Installing the SystemInstal

Page 205 - Procedure

Case Study: Installing and Configuring a SystemHP NonStop S-Series Hardware Installation and FastPath Guide—541880-00114-23Adding Ethernet 4 ServerNet

Page 206

Case Study: Installing and Configuring a SystemHP NonStop S-Series Hardware Installation and FastPath Guide—541880-00114-24Adding ConMgr Process== Add

Page 207

Case Study: Installing and Configuring a SystemHP NonStop S-Series Hardware Installation and FastPath Guide—541880-00114-25Configuring NonStop TCP/IP

Page 208

Case Study: Installing and Configuring a SystemHP NonStop S-Series Hardware Installation and FastPath Guide—541880-00114-26Configuring NonStop TCP/IP

Page 209 - VST069.vsd

Case Study: Installing and Configuring a SystemHP NonStop S-Series Hardware Installation and FastPath Guide—541880-00114-27Adding Persistent CLCI TACL

Page 210 - VST070.vsd

Case Study: Installing and Configuring a SystemHP NonStop S-Series Hardware Installation and FastPath Guide—541880-00114-28Adding a SWAN ConcentratorA

Page 211 - Unattended Site Configuration

Case Study: Installing and Configuring a SystemHP NonStop S-Series Hardware Installation and FastPath Guide—541880-00114-29Adding CP6100 LinesAdding C

Page 212

About This GuideHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001xxviiNotation for MessagesIf there is no space between two item

Page 213

Case Study: Installing and Configuring a SystemHP NonStop S-Series Hardware Installation and FastPath Guide—541880-00114-30Adding an ATP6100 LineAddin

Page 214

Case Study: Installing and Configuring a SystemHP NonStop S-Series Hardware Installation and FastPath Guide—541880-00114-31Adding a 5516 PrinterAdding

Page 215

Case Study: Installing and Configuring a SystemHP NonStop S-Series Hardware Installation and FastPath Guide—541880-00114-32Adding an X.25 LineAdding a

Page 216

Case Study: Installing and Configuring a SystemHP NonStop S-Series Hardware Installation and FastPath Guide—541880-00114-33Configuring and Starting th

Page 217 - Offline Configuration Tasks

Case Study: Installing and Configuring a SystemHP NonStop S-Series Hardware Installation and FastPath Guide—541880-00114-34Adding a Direct-Connect Lin

Page 218 - Installing a Product Revision

HP NonStop S-Series Hardware Installation and FastPath Guide—541880-001A-1A Part NumbersFor all part numbers, see:•The Support and Service Library. Fo

Page 219 - Changing the CONFTEXT File

Part NumbersHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001A-2

Page 220

HP NonStop S-Series Hardware Installation and FastPath Guide—541880-001B-1B ServerNet Cabling This appendix contains ServerNet cabling diagrams and ta

Page 221 - 12 Online Configuration Tasks

ServerNet CablingHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001B-2What ServerNet Cabling Diagrams MeanWhat ServerNet Cabling

Page 222 - Initial CONFIG file

ServerNet CablingHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001B-3What ServerNet Cabling Diagrams MeanFigure B-2. Correlation

Page 223 - Subsystems in G-Series RVUs

Hewlett-Packard Company—541880-001iHP NonStop S-Series Hardware Installation and FastPath GuideGlossary Index Examples Figures TablesWhat’s New in Th

Page 224 - Generic Processes

About This GuideHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001xxviiiChange Bar Notation

Page 225

ServerNet CablingHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001B-4Maximum ServerNet ConfigurationsMaximum ServerNet Configura

Page 226

ServerNet CablingHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001B-5Maximum ServerNet ConfigurationsFigure B-4. Maximum Tetra 1

Page 227 - VST911.vsd

ServerNet CablingHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001B-6Maximum ServerNet ConfigurationsFigure B-5. Maximum Tetra 1

Page 228

ServerNet CablingHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001B-7Maximum ServerNet Cabling TablesMaximum ServerNet Cabling T

Page 229 - The OSM and TSM Packages

ServerNet CablingHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001B-8Tetra 8 Cabling TablesTetra 8 Cabling Tables Table PageMaxi

Page 230

ServerNet CablingHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001B-9Tetra 8 Cabling TablesTable B-2. Maximum Tetra 8 ServerNet

Page 231

ServerNet CablingHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001B-10Tetra 16 Cabling TablesTetra 16 Cabling TablesTable PageMa

Page 232

ServerNet CablingHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001B-11Tetra 16 Cabling Tables04 52 1 03 52 1 04 51 5 08 51 5 04

Page 233

ServerNet CablingHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001B-12Tetra 16 Cabling Tables31 55 03 54 1 32 50 03 53 2 32 55 0

Page 234

ServerNet CablingHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001B-13Tetra 16 Cabling Tables64 55 06 52 4 71 50 07 51 171 55 07

Page 235

HP NonStop S-Series Hardware Installation and FastPath Guide—541880-0011-11 IntroductionThis section summarizes the installation process and gives an

Page 236

ServerNet CablingHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001B-14Small Tetra 8 SystemsSmall Tetra 8 SystemsThis subsection

Page 237 - Create a Command File

ServerNet CablingHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001B-15Tetra 8 Systems With One Processor EnclosureTetra 8 System

Page 238

ServerNet CablingHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001B-16Tetra 8 Systems With Two Processor EnclosuresTetra 8 Syste

Page 239 - NonStop S-series server

ServerNet CablingHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001B-17Tetra 8 Systems With Three Processor EnclosuresTetra 8 Sys

Page 240 - For More Information

ServerNet CablingHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001B-18Tetra 8 Systems With Three Processor EnclosuresThree Proce

Page 241 - $YMIOP.#CNSL

ServerNet CablingHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001B-19Tetra 8 Systems With Three Processor Enclosures02 51 Serve

Page 242 - $ZHOME Alternative

ServerNet CablingHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001B-20Tetra 8 Systems With Three Processor EnclosuresThree Proce

Page 243 - Example Command Files

ServerNet CablingHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001B-21Tetra 8 Systems With Four Processor EnclosuresTetra 8 Syst

Page 244 - CIIN File

ServerNet CablingHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001B-22Tetra 8 Systems With Four Processor EnclosuresFour Process

Page 245 - Modifying a CIIN File

ServerNet CablingHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001B-23Tetra 8 Systems With Four Processor EnclosuresFour Process

Page 246 - Example CIIN Files

IntroductionHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0011-2Installation OverviewIOAM Enclosure Cabling 1-37ServerNet Cables

Page 247 - Configuration and Startup

ServerNet CablingHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001B-24Tetra 8 Systems With Four Processor Enclosures21 (I/O) 55

Page 248 - Startup File Examples

ServerNet CablingHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001B-25Small Tetra 16 SystemsSmall Tetra 16 SystemsAbout This Inf

Page 249

ServerNet CablingHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001B-26Tetra 16 Systems With Four Processor EnclosuresTetra 16 Sy

Page 250 - TMF Warm-Start File

ServerNet CablingHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001B-27Tetra 16 Systems With Four Processor EnclosuresFigure B-9.

Page 251 - $ZZLAN.L018

ServerNet CablingHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001B-28Tetra 16 Systems With Six Processor EnclosuresTetra 16 Sys

Page 252

ServerNet CablingHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001B-29Tetra 16 Systems With Six Processor EnclosuresFigure B-11.

Page 253 - X.25 Lines Startup File

ServerNet CablingHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001B-30Tetra 16 Systems With Six Processor Enclosures

Page 254 - Printer Line Startup File

HP NonStop S-Series Hardware Installation and FastPath Guide—541880-001C-1C Power-On CablingThis section provides power-on cabling diagrams for select

Page 255 - Shutdown File Examples

Power-On CablingHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001C-2Figure C-1. Power-On Cabling: Single-High Stacks VST805.vsdM

Page 256 - System Shutdown File

Power-On CablingHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001C-3Figure C-2. Power-On Cabling: Mixed Single-High and Double-H

Page 257 - X.25 Lines Shutdown File

IntroductionHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0011-3Installation OverviewInstallation Overview Step Documentation No

Page 258 - Printer Line Shutdown File

Power-On CablingHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001C-4Figure C-3. Power-On Cabling: Multiple-Row Systems Diagonal

Page 259 - Adding Super-Group User IDs

Power-On CablingHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001C-5Figure C-4. Power-On Cable: One Processor EnclosureFigure C-

Page 260

Power-On CablingHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001C-6 Figure C-7. Power-On Cables: Two Processor Enclosures, No

Page 261 - Configuring a System

Power-On CablingHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001C-7 Figure C-10. Power-On Cables: Three Processor Enclosures, N

Page 262 - About These Examples

Power-On CablingHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001C-8 Figure C-13. Power-On Cables: Three Processor Enclosures, T

Page 263 - VST919.vsd

Power-On CablingHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001C-9Figure C-17. Power-On Cables: Four Processor Enclosures, Thr

Page 264 - Installation Documents

Power-On CablingHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001C-10

Page 265 - VST305.vsd

HP NonStop S-Series Hardware Installation and FastPath Guide—541880-001D-1D TroubleshootingThis appendix explains basic recovery tasks for the system

Page 266 - VST306.vsd

TroubleshootingHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001D-2ReferenceReferencePower StatesThis table summarizes the NonSt

Page 267 - VST316.vsd

TroubleshootingHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001D-3Power StatesThe system is operating normally. The batteries a

Page 268 - Case Study: Floor Plan

IntroductionHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0011-4Installation OverviewSection 5, Installing, Starting, and Testin

Page 269 - VST231.vsd

TroubleshootingHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001D-4Status LEDsStatus LEDsLocation LED Name Color Function (page

Page 270 - VST203.vsd

TroubleshootingHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001D-5Powering On the SystemPowering On the SystemPMF CRU Power-on

Page 271 - Configuration Form

TroubleshootingHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001D-6System Does Not Appear to Be Powered OnSystem Does Not Appear

Page 272

TroubleshootingHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001D-7Power Is Applied to Enclosure But Fans Are NotTurningb. Press

Page 273 - VST234.vsd

TroubleshootingHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001D-8Any Green LED Is Not LitAny Green LED Is Not Lit 1. Make sure

Page 274 - VST235.vsd

TroubleshootingHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001D-9Any Amber LED Remains Lit After POSTAny Amber LED Remains Lit

Page 275 - VST205.vsd

TroubleshootingHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001D-10Starting the SystemStarting the System Startup Event Stream

Page 276 - ETHERNET

TroubleshootingHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001D-11System Load FailsSystem Load Fails If a system load is not s

Page 277

TroubleshootingHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001D-12CIIN File Is Not Invoked During System Startup2. If the curr

Page 278 - VST236.vsd

TroubleshootingHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001D-13Reload FailsReload Fails If a reload is not successful: 1. C

Page 279 - VST239.vsd

IntroductionHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0011-5Installation OverviewStandard Operating PracticesWhen you handle

Page 280 - Registry of IP Addresses

TroubleshootingHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001D-14CPU Memory Test FailsCPU Memory Test FailsThe CPU memory tes

Page 281

TroubleshootingHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001D-15Multifunction I/O Board (MFIOB) Test FailsMultifunction I/O

Page 282 - Customizing the Configuration

TroubleshootingHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001D-16Dumping Processor MemoryDumping Processor MemoryYou can dump

Page 283

TroubleshootingHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001D-17Dumping Processor Memory to Disk OnlinePrerequisitesBefore y

Page 284 - Adding ConMgr Process

TroubleshootingHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001D-18Dumping Processor Memory to Disk Online•If dumpfile does not

Page 285

TroubleshootingHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001D-19Dumping Processor Memory to Disk OnlineIf a message indicate

Page 286

TroubleshootingHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001D-20Dumping Processor Memory to Tape OfflineDumping Processor Me

Page 287 - Processes

TroubleshootingHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001D-21Dumping Processor Memory to Tape Offline7. In the Processor

Page 288 - Adding a SWAN 2 Concentrator

TroubleshootingHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001D-22Expand-Over-IP ConnectionsExpand-Over-IP ConnectionsYou can

Page 289 - Adding CP6100 Lines

TroubleshootingHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001D-23Expand-Over-IP ConnectionsPASSIVE If the Expand-over-IP line

Page 290 - Adding an ATP6100 Line

IntroductionHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0011-6Installation OverviewUsing ESD ProtectionVST693.vsdESD antistati

Page 291 - Adding a 5516 Printer

TroubleshootingHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001D-24Recovery Actions for the CONNECTING StateRecovery Actions fo

Page 292 - Adding an X.25 Line

TroubleshootingHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001D-25Recovery Actions for the WAIT StateFor cause, effect, and re

Page 293 - Adding an Expand-Over-IP Line

TroubleshootingHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001D-26Backing Out a Software RevisionBacking Out a Software Revisi

Page 294 - Adding a Direct-Connect Line

TroubleshootingHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001D-272. Start and Log On to Target Interface2. Start and Log On t

Page 295 - A Part Numbers

TroubleshootingHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001D-284. Monitor Backout Process4. Monitor Backout Process1. From

Page 296 - Part Numbers

TroubleshootingHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001D-296. Rename Software Files Using ZPHIRNM6. Rename Software Fil

Page 297 - B ServerNet Cabling

TroubleshootingHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001D-308. Load System From Saved Configuration8. Load System From S

Page 298 - ServerNet Cabling

TroubleshootingHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001D-31System ConsolesSystem Consoles Your new system console is sh

Page 299

TroubleshootingHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001D-32System ConsolesConnectivity ProblemsConnectivity refers to t

Page 300

TroubleshootingHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001D-33System ConsolesMouse Is InoperativeTable D-3. Mouse Is Inope

Page 301

IntroductionHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0011-7Installation OverviewToolsThe tools you might need when installi

Page 302

TroubleshootingHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001D-34System ConsolesMonitor Screen Is BlankTable D-4. Monitor Scr

Page 303 - Shaded Areas in These Tables

TroubleshootingHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001D-35System ConsolesSystem Unit Is InoperativeTable D-5. System U

Page 304 - Tetra 8 Cabling Tables

TroubleshootingHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001D-36Software Configuration ProblemsSoftware Configuration Proble

Page 305

TroubleshootingHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001D-37Software Corruption and Hard-Disk ProblemsSoftware Corruptio

Page 306 - Tetra 16 Cabling Tables

TroubleshootingHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001D-38Restoring Software on the Hard DiskRestoring Software on the

Page 307

TroubleshootingHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001D-39Restoring Software on the Hard DiskInstall Operating System

Page 308

TroubleshootingHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001D-40Restoring Software on the Hard Disk14. Click I accept this a

Page 309

TroubleshootingHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001D-41Restoring Software on the Hard Disk32. Verify that the Workg

Page 310 - Small Tetra 8 Systems

TroubleshootingHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001D-42Restoring Software on the Hard Disk52. Select Do not allow v

Page 311

TroubleshootingHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001D-43Restoring Software on the Hard DiskConfigure the System Cons

Page 312

IntroductionHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0011-8Installation OverviewInstallation Checklist Task See...Prepare t

Page 313 - VST300.vsd

TroubleshootingHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001D-44Restoring Software on the Hard DiskSet Event Log SettingsThi

Page 314

TroubleshootingHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001D-45Restoring Software on the Hard DiskInstall Software Provided

Page 315

TroubleshootingHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001D-46Restoring Software on the Hard DiskInstall Internet Explorer

Page 316 - VST800.vsd

TroubleshootingHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001D-47Restoring Software on the Hard DiskConfigure the System Cons

Page 317

TroubleshootingHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001D-48Configuring a ProCurve 24-Port Ethernet Switch Configuring a

Page 318

HP NonStop S-Series Hardware Installation and FastPath Guide—541880-001E-1E FastPath Tasks: RequiredThis appendix contains all the tasks required to i

Page 319

FastPath Tasks: RequiredHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001E-23. Verify Disk Drives E-314. Verify Tape Drive E-325

Page 320

FastPath Tasks: RequiredHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001E-31. Install Hardware1. Install Hardware Task Page1. I

Page 321 - Small Tetra 16 Systems

FastPath Tasks: RequiredHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001E-41. Inventory Shipment1. Inventory Shipment1a. Invent

Page 322

FastPath Tasks: RequiredHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001E-51. Inventory Shipment1b. Inventory Equipment1. Verif

Page 323

IntroductionHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0011-9Installation OverviewShipping Packages Each enclosure or stack o

Page 324

FastPath Tasks: RequiredHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001E-62. Collect Tools2. Collect Tools 3. Unpack and Unloa

Page 325

FastPath Tasks: RequiredHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001E-73. Unpack and Unload Server4. Prepare to roll the en

Page 326

FastPath Tasks: RequiredHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001E-83. Unpack and Unload Serverc. Position the unloading

Page 327 - C Power-On Cabling

FastPath Tasks: RequiredHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001E-93. Unpack and Unload Server5. Roll the enclosure or

Page 328 - VST805.vsd

FastPath Tasks: RequiredHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001E-104. Connect Groundstraps4. Connect GroundstrapsIf th

Page 329 - VST806.vsd

FastPath Tasks: RequiredHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001E-115. Inventory and Inspect All Components5. Inventory

Page 330 - VST000.vsd

FastPath Tasks: RequiredHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001E-126. Connect the Power-On CablesFigure E-10. Power-On

Page 331 - VST111.vsd

FastPath Tasks: RequiredHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001E-137. Connect Emergency Power-Off (EPO) Cables7. Conne

Page 332 - Power-On Cabling

FastPath Tasks: RequiredHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001E-148. Connect ServerNet Cables8. Connect ServerNet Cab

Page 333

FastPath Tasks: RequiredHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001E-159. Install Service-Side Enclosure Doors If Necessar

Page 334 - Enclosures

ContentsHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001ii1. Introduction (continued)1. Introduction (continued)Emergency Power

Page 335

IntroductionHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0011-10Installation OverviewShipping Package SpecificationsFigure 1-1.

Page 336

FastPath Tasks: RequiredHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001E-1610. Install Primary System Console10. Install Prima

Page 337 - D Troubleshooting

FastPath Tasks: RequiredHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001E-1710. Install Primary System Console2. Store the back

Page 338 - Reference

FastPath Tasks: RequiredHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001E-1811. Create Emergency Repair Disk or AutomatedSystem

Page 339 - Power States

FastPath Tasks: RequiredHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001E-1914. Connect Primary System Console to EthernetSwitc

Page 340 - Status LEDs

FastPath Tasks: RequiredHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001E-2015. Install Tape Drive10. Depending on the model of

Page 341 - Powering On the System

FastPath Tasks: RequiredHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001E-2115. Install Tape DriveInstalling a 519x Tape Drive1

Page 342

FastPath Tasks: RequiredHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001E-222. Start the System2. Start the System 1. Prepare f

Page 343

FastPath Tasks: RequiredHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001E-232. Power On External System Devices2. Power On Exte

Page 344 - Any Green LED Is Not Lit

FastPath Tasks: RequiredHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001E-243. Connect AC Power Cords3. Connect AC Power CordsE

Page 345 - Correcting Topology Attribute

FastPath Tasks: RequiredHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001E-253. Connect AC Power CordsEnclosures With Power Shel

Page 346

IntroductionHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0011-11Installation OverviewFigure 1-2. Shipping Package Dimensions VS

Page 347 - System Load Fails

FastPath Tasks: RequiredHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001E-264. Apply Power to Server4. Apply Power to Server1.

Page 348

FastPath Tasks: RequiredHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001E-275. Verify Topology5. Verify Topology1. Log on to th

Page 349 - Reload Fails

FastPath Tasks: RequiredHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001E-286. Verify System Components6. Verify System Compone

Page 350 - System Load Path Test Fails

FastPath Tasks: RequiredHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001E-297. Start SystemThe operating system is loaded into

Page 351

FastPath Tasks: RequiredHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001E-303. Verify the System3. Verify the System 1. Verify

Page 352 - Dumping Processor Memory

FastPath Tasks: RequiredHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001E-312. Verify Critical System Processes2. Verify Critic

Page 353 - Prerequisites

FastPath Tasks: RequiredHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001E-324. Verify Tape Drive4. Verify Tape Drive1. Enter th

Page 354

FastPath Tasks: RequiredHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001E-334. Configure the System4. Configure the System Use

Page 355

FastPath Tasks: RequiredHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001E-341. Configure Passwords1. Configure Passwords1a. Con

Page 356

FastPath Tasks: RequiredHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001E-352. Configure Kernel-Managed Swap Files2. Configure

Page 357

IntroductionHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0011-12Installation OverviewEnclosure TypesEnclosures can be described

Page 358 - Expand-Over-IP Connections

FastPath Tasks: RequiredHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001E-363. Configure OSM or TSM Environment3. Configure OSM

Page 359

FastPath Tasks: RequiredHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001E-374. Configure System Attributes4. Configure System A

Page 360

FastPath Tasks: RequiredHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001E-384. Configure System Attributes4b. Set System Name,

Page 361

FastPath Tasks: RequiredHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001E-394. Configure System Attributes4c. Restart System1.

Page 362 - 1. Start DSM/SCM

FastPath Tasks: RequiredHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001E-404. Configure System Attributes4e. Invoke STARTCOM a

Page 363 - 3. Initiate Backout Activity

FastPath Tasks: RequiredHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001E-415. Configure DSM/SCM5. Configure DSM/SCMPerform thi

Page 364 - 5. Stop All Applications

FastPath Tasks: RequiredHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001E-425. Configure DSM/SCM5b. Configure DSM/SCM System En

Page 365 - 7. Stop System

FastPath Tasks: RequiredHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001E-435. Configure DSM/SCM5c. Configure Host Information

Page 366 - 9. Start Applications

FastPath Tasks: RequiredHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001E-445. Configure DSM/SCM5d. Configure Target Informatio

Page 367 - System Consoles

FastPath Tasks: RequiredHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001E-455. Install the Backup System Console5. Install the

Page 368 - Keyboard Is Inoperative

IntroductionHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0011-13Installation OverviewEnclosure PositionsSystem enclosures can b

Page 369 - Mouse Is Inoperative

FastPath Tasks: RequiredHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001E-465. Install the Backup System Console14. Connect an

Page 370 - Monitor Screen Is Blank

HP NonStop S-Series Hardware Installation and FastPath Guide—541880-001F-1F FastPath Tasks: Optional This appendix contains all optional configuration

Page 371 - System Unit Is Inoperative

FastPath Tasks: OptionalHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001F-21. Prerequisites1. PrerequisitesBefore you change th

Page 372 - Monitor Screen Is Frozen

FastPath Tasks: OptionalHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001F-31d. Save Current System Configuration1d. Save Curren

Page 373

FastPath Tasks: OptionalHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001F-42. Customize the System Configuration2. Customize th

Page 374

FastPath Tasks: OptionalHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001F-52b. Rename SCF Objects in the CONFIG File2b. Rename

Page 375 - Install the Operating System

FastPath Tasks: OptionalHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001F-62c. Add SCF Objects to the CONFIG File2c. Add SCF Ob

Page 376

FastPath Tasks: OptionalHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001F-73. Automate System Startup3. Automate System Startup

Page 377

FastPath Tasks: OptionalHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001F-84. Automate System Shutdown4. Automate System Shutdo

Page 378

FastPath Tasks: OptionalHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001F-95. Configure a SWAN or SWAN 2 Concentrator5. Configu

Page 379 - Configure the System Console

IntroductionHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0011-14Installation OverviewIOAM Enclosure ComponentsAn IOAM enclosure

Page 380 - Set Event Log Settings

FastPath Tasks: OptionalHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001F-106. Configure an Expand-Over-IP Line6. Configure an

Page 381 - Install DSM/SCM

FastPath Tasks: OptionalHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001F-11PrerequisitesPrerequisitesThe NonStop S-series and

Page 382 - Install Internet Explorer

FastPath Tasks: OptionalHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001F-121. On the NonStop S-Series Server1. On the NonStop

Page 383 - Service Connection

FastPath Tasks: OptionalHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001F-131. On the NonStop S-Series Server1c. Configure $NCP

Page 384

FastPath Tasks: OptionalHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001F-141. On the NonStop S-Series ServerTo list all NonSto

Page 385 - E FastPath Tasks: Required

FastPath Tasks: OptionalHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001F-151. On the NonStop S-Series Server6. Determine a Use

Page 386 - FastPath Tasks: Required

FastPath Tasks: OptionalHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001F-162. On the NonStop K-Series Server2. On the NonStop

Page 387 - 1. Install Hardware

FastPath Tasks: OptionalHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001F-172. On the NonStop K-Series Server6. Record the prim

Page 388 - 1. Inventory Shipment

FastPath Tasks: OptionalHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001F-183. On the NonStop S-Series Server3. On the NonStop

Page 389 - 1b. Inventory Equipment

FastPath Tasks: OptionalHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001F-194. On the NonStop K-Series Server4. On the NonStop

Page 390 - 3. Unpack and Unload Server

IntroductionHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0011-15Installation Overviewenclosure and the OSM console. The mainten

Page 391

FastPath Tasks: OptionalHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001F-204. On the NonStop K-Series Server4. In Table F-2, C

Page 392

FastPath Tasks: OptionalHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001F-215. On Either NonStop Server5. On Either NonStop Ser

Page 393 - Group 11

FastPath Tasks: OptionalHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001F-227. Install Software7. Install SoftwareThis section

Page 394 - 4. Connect Groundstraps

FastPath Tasks: OptionalHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001F-23Configuring Software With DSM/SCMConfiguring Softwa

Page 395 - VST703.vsd

FastPath Tasks: OptionalHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001F-24Configuring Software With DSM/SCM3. Build and Apply

Page 396 - VST122.vsd

FastPath Tasks: OptionalHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001F-25Installing a Software Product Revision (SPR)Install

Page 397

FastPath Tasks: OptionalHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001F-26Installing a Software Product Revision (SPR)2. Log

Page 398 - 8. Connect ServerNet Cables

FastPath Tasks: OptionalHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001F-27Installing a Software Product Revision (SPR)4. Crea

Page 399

FastPath Tasks: OptionalHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001F-28Installing a Software Product Revision (SPR)f. To s

Page 400

FastPath Tasks: OptionalHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001F-29Installing a Software Product Revision (SPR)b. Run

Page 401

IntroductionHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0011-16Installation OverviewEnclosure IllustrationsFigure 1-3. Base an

Page 402 - VST519.vsd

FastPath Tasks: OptionalHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001F-30Installing a Software Product Revision (SPR)

Page 403 - Installing a 5175 Tape Drive

HP NonStop S-Series Hardware Installation and FastPath Guide—541880-001Statements-1Safety and ComplianceThis sections contains three types of required

Page 404 - VST016.vsd

Safety and ComplianceHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001Statements-2Regulatory Compliance StatementsKorea MIC Comp

Page 405 - Installing a 519x Tape Drive

Safety and ComplianceHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001Statements-3Regulatory Compliance StatementsEuropean Union

Page 406 - 2. Start the System

Safety and ComplianceHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001Statements-4SAFETY CAUTIONSAFETY CAUTIONThe following icon

Page 407

Safety and ComplianceHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001Statements-5Waste Electrical and Electronic Equipment (WEE

Page 408 - 3. Connect AC Power Cords

Safety and ComplianceHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001Statements-6Safety

Page 409

HP NonStop S-Series Hardware Installation and FastPath Guide—541880-001Glossary-1GlossaryFor a glossary of NonStop S-series terms, see the NonStop Ser

Page 410 - 4. Apply Power to Server

GlossaryHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001Glossary-2

Page 411 - 5. Verify Topology

HP NonStop S-Series Hardware Installation and FastPath Guide—541880-001Index-1IndexNumbers3883/4/5 AWAN serverSee AWAN3886-8/16/32 AWAN serverSee AWAN

Page 412 - 7. Start System

IntroductionHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0011-17Installation OverviewFigure 1-4. SEBs in a Processor Enclosure

Page 413

IndexHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001Index-2CCable (continued)ServerNetsee ServerNet cablesupports 1-43, 3-6tie

Page 414 - 3. Verify the System

IndexHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001Index-3DCONFIG file 8-18, 9-14customizing F-4function 12-3initial 12-2type

Page 415

IndexHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001Index-4EDisk drivesLEDs D-4replacing 9-10testing 9-8/9-10Disk-drive enclos

Page 416 - 4. Verify Tape Drive

IndexHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001Index-5FEnclosure (continued)slot assignments 2-16, 2-17stack 1-13, 2-10to

Page 417 - 4. Configure the System

IndexHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001Index-6GFirmwareintelligent SCSI processor D-14ISP D-14requirements 7-3, 7

Page 418 - 1. Configure Passwords

IndexHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001Index-7KIOMF CRUEthernet ports 6-2LEDs 8-10, D-4power-on self-test (POST)

Page 419

IndexHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001Index-8MLoad path, operating system 1-55Loading the system 8-18Local area

Page 420

IndexHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001Index-9POpen-reel tapeSee Tape subsystemOperating configurationSee Recomme

Page 421 - -> SAVE CONFIGURATION 1.4

IndexHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001Index-10QPrimary system console E-16about 1-3, 1-47, 10-3configuring E-36i

Page 422

IndexHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001Index-11SScreenSee MonitorSCSI cables 7-7, 7-10SEBscables 1-40, E-14cablin

Page 423 - 4c. Restart System

IntroductionHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0011-18Installation Overview.Figure 1-5. MSEBs in a Processor Enclosur

Page 424

IndexHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001Index-12SShutdown files (continued)X.25 lines 13-19Single-mode fiber (SMF)

Page 425 - 5. Configure DSM/SCM

IndexHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001Index-13TSystem consoleassembling 5-6/5-7backup 10-3binder E-17connecting

Page 426

IndexHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001Index-14UTSMabout 1-45, 1-46CIIN file 13-7client software 1-46configuring

Page 427

IndexHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001Index-15Special Characters$ZHOME 13-3$ZPM 12-3$ZTCP default IP addresses 1

Page 428

IndexHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001Index-16Special Characters

Page 429

IntroductionHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0011-19Installation OverviewFigure 1-6. Service Side of I/O Enclosure

Page 430

ContentsHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001iii3. Cabling Enclosures3. Cabling Enclosures1. Connect Power-On Cables

Page 431 - F FastPath Tasks: Optional

IntroductionHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0011-20Installation OverviewFigure 1-7 illustrates the service side of

Page 432 - 1. Prerequisites

IntroductionHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0011-21Installation OverviewFigure 1-8. Rack with IOAM Enclosure (Fron

Page 433 - FastPath Tasks: Optional

IntroductionHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0011-22Installation OverviewFigure 1-9. Rack With IOAM Enclosure (Rear

Page 434 - 2a. Change SCF

IntroductionHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0011-23Installation OverviewGroundstrapsWhat Groundstraps DoGroundstra

Page 435

IntroductionHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0011-24Installation OverviewPower-On CablesPower-on cables carry the p

Page 436

IntroductionHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0011-25Installation OverviewEmergency Power-Off CablesEmergency power-

Page 437 - 3. Automate System Startup

IntroductionHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0011-26Installation OverviewIf a System Does Not Require EPO Capabilit

Page 438 - 4. Automate System Shutdown

IntroductionHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0011-27Installation OverviewGroup, Module, and Slot Hierarchy Illustra

Page 439 - Access the WAN Wizard Pro

IntroductionHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0011-28Installation OverviewGroup, Module, and Slot Hierarchy for IOAM

Page 440

IntroductionHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0011-29Installation OverviewGroup, Module, and Slot Hierarchy Illustra

Page 441 - NonStop K-Series Server

ContentsHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001iv7. Installing External System Devices7. Installing External System D

Page 442 - 1b. Configure $ZEXP

IntroductionHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0011-30Installation OverviewThis figure shows the rear of an IOAM encl

Page 443 - 1d. Obtain TCP/IP Information

IntroductionHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0011-31Installation OverviewServer Numbering and LabelingA NonStop ser

Page 444

IntroductionHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0011-32Installation OverviewGroup ID SwitchesSet group identification

Page 445

IntroductionHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0011-33Installation OverviewIdentification LabelsIdentification labels

Page 446 - 2a. Obtain TCP/IP Information

IntroductionHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0011-34Installation OverviewIOAM Enclosure ServerNet Switch Board LCDE

Page 447

IntroductionHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0011-35Installation OverviewThis figure shows the LCD of a ServerNet s

Page 448

IntroductionHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0011-36Installation OverviewTopologiesSystems can be configured in two

Page 449 - Process

IntroductionHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0011-37Installation OverviewOther components, such as ServerNet/FX ada

Page 450

IntroductionHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0011-38Installation OverviewTable 1-4. ServerNet Cable Compatibilities

Page 451 - 5. On Either NonStop Server

IntroductionHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0011-39Installation OverviewFigure 1-12. Port Numbers and Cable Connec

Page 452 - 7. Install Software

ContentsHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001v9. Performing Post-Startup Tasks (continued)9. Performing Post-Startup

Page 453 - 2. Create Software Revision

IntroductionHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0011-40Installation OverviewTypes of ServerNet CablesNonStop S-series

Page 454

IntroductionHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0011-41Installation OverviewSerial-Copper CablesSerial-copper cables a

Page 455

IntroductionHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0011-42Installation OverviewFiber-Optic Cables With LC-SC ConnectorsFo

Page 456 - 3. Receive SPR Into Archive

IntroductionHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0011-43Installation OverviewCable LabelsLabel both ends of each cable.

Page 457

IntroductionHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0011-44Installation Overview Figure 1-21. Cable-Management Hardware 02

Page 458 - 6. Activate Software

IntroductionHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0011-45Installation OverviewThe System ConsoleThis subsection describe

Page 459

IntroductionHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0011-46Installation OverviewThe OSM ProductFor the G06.22 RVU, the HP

Page 460

IntroductionHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0011-47Installation OverviewPrimary and Backup System ConsolesSystem c

Page 461

IntroductionHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0011-48Installation OverviewModemsModems modulate or demodulate digita

Page 462 - Japan (VCCI) Compliance

IntroductionHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0011-49Installation OverviewDial-InsDial-in capability lets a remote s

Page 463 - Laser Compliance

ContentsHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001vi12. Online Configuration Tasks12. Online Configuration TasksSCF 12-2I

Page 464 - NOT FOR EXTERNAL USE

IntroductionHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0011-50Installation OverviewTable 1-5. Preloaded and Supported HP NonS

Page 465 - FUSE REPLACEMENT

IntroductionHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0011-51Installation OverviewWAN Wizard Pro A graphical user interface

Page 466 - Statements-6

IntroductionHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0011-52Installation OverviewPreconfigured IP AddressesNew systems are

Page 467

IntroductionHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0011-53Installation OverviewMSP IP addresses communicate with the mast

Page 468 - Glossary-2

IntroductionHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0011-54Installation OverviewSoftware ConnectionsA system console can c

Page 469

IntroductionHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0011-55Installation OverviewSystem StartupStartup and Shutdown FilesSt

Page 470

IntroductionHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0011-56Installation OverviewThe command interpreter input (CIIN) file

Page 471

IntroductionHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0011-57Installation OverviewPMF CRU and IOMF CRU Power-On Self-TestsWh

Page 472

IntroductionHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0011-58Installation Overview

Page 473

HP NonStop S-Series Hardware Installation and FastPath Guide—541880-0012-12 Installing EnclosuresThis section describes how to unpack new equipment an

Page 474

ContentsHP NonStop S-Series Hardware Installation and FastPath Guide—541880-001vii13. Creating Startup and ShutdownFiles (continued)13. Creating Star

Page 475

Installing EnclosuresHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0012-2Prepare to Install New EquipmentPrepare to Install New

Page 476

Installing EnclosuresHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0012-32. Prepare the Work Space2. Prepare the Work Space1. Cl

Page 477

Installing EnclosuresHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0012-43. Organize the Equipment3. Organize the Equipment1. So

Page 478 - Index-10

Installing EnclosuresHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0012-53. Organize the Equipment4. Find the System Image Tape

Page 479 - Index-11

Installing EnclosuresHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0012-6Unpack the Enclosures9. Report any missing or damaged i

Page 480 - Index-12

Installing EnclosuresHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0012-7Unpack the EnclosuresFigure 2-2. Unpacking the Enclosur

Page 481 - Index-13

Installing EnclosuresHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0012-8Unpack the Enclosures4. Open the plastic locking clips

Page 482 - Index-14

Installing EnclosuresHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0012-9Unpack the Enclosures10. Remove the end piece and set i

Page 483 - $ZPM 12-3

Installing EnclosuresHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0012-10Unpack the Enclosures12. To prevent snagging hazards a

Page 484 - Special Characters

Installing EnclosuresHP NonStop S-Series Hardware Installation and FastPath Guide—541880-0012-11Unpack the Enclosures13. Using at least two people, gr

Commentaires sur ces manuels

Pas de commentaire