Error messages 126
Real-Time Clock Battery Failing
Event Type: System configuration battery low
Action: Replace the system configuration battery.
System AC Power Overload (Power Supply X)
Event Type: Power supply overload
Action:
1. Switch the voltage from 110 V to 220 V or add an additional power supply (if applicable to the
system).
2. If the problem persists, remove some of the installed options.
System AC Power Problem (Power Supply X)
Event Type: AC voltage problem
Action: Check for any power source problems.
System Fan Failure (Fan X, Location)
Event Type: Fan failure
Action: Replace the fan.
System Fans Not Redundant
Event Type: Fans not redundant
Action: Add a fan or replace the failed fan.
System Overheating (Zone X, Location)
Event Type: Overheating condition
Action: Check fans.
System Power Supplies Not Redundant
Event Type: Power supply not redundant
Action: Add a power supply or replace the failed power supply.
System Power Supply Failure (Power Supply X)
Event Type: Power supply failure
Action: Replace the power supply.
Unrecoverable Host Bus Data Parity Error...