BUD Failed, SIFSTS = XXXX
Meaning: The token ring device Bring Up Diagnostic (BUD) failed, indicating a
possible hardware failure.
Action: Note the code number in the event message and contact your
Hewlett-Packard representative.
Call collision will rcv inbound call
Meaning: The router received an incoming call after sending a connect request
(CRN command). The connect request will be stopped and the incoming
call accepted if it doesn’t fail any user-specified call restrictions placed
on inbound calls.
Call coll to IP next hop
X.X.X.X
Meaning: We were attempting to establish an outbound call to next hop X.X.X.X
when we received an inbound call from that location. The outbound call
will be closed and the inbound call will be used.
Can’t configure 4 Mbps token interface
Meaning: You have configured 4 Mbit/s service on a 16 Mbit/s medium.
Action: Reconfigure the Ring Interface parameter setting correctly for your
medium.
Can’t configure 16 Mbps token interface
Meaning: You have configured 16 Mbit/s service on a 4 Mbit/s medium.
Action: Reconfigure the Ring Interface parameter setting correctly for your
medium.
Carrier Detect lost on WAN
#
Meaning: Carrier Detect has been lost on the indicated WAN.