HP gnu source-level debugger 5992-4701 Manuel d'utilisateur Page 90

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 369
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 89
disable display dnums... Disable the display of item numbers dnums. A
disabled display item is not printed
automatically, but is not forgotten. It may be
enabled again later.
enable display dnums... Enable display of item numbers dnums. It
becomes effective once again in auto display of
its expression, until you specify otherwise.
display
Display the current values of the expressions on
the list, just as is done when your program stops.
info display
Print the list of expressions previously set up to
display automatically, each one with its item
number, but without showing the values. This
includes disabled expressions, which are marked
as such. It also includes expressions which would
not be displayed right now because they refer to
automatic variables not currently available.
If a display expression refers to local variables, then it does not make sense outside the
lexical context for which it was set up. Such an expression is disabled when execution
enters a context where one of its variables is not defined. For example, if you give the
command display last_char while inside a function with an argument last_char,
GDB displays this argument while your program continues to stop inside that function.
When it stops elsewhere, where there is no variable last_char, the display is disabled
automatically. The next time your program stops where last_char is meaningful,
you can enable the display expression again.
8.7 Print settings
GDB provides the following ways to control how arrays, structures, and symbols are
printed.
These settings are useful for debugging programs in any language:
set print address, set
print address on
GDB prints memory addresses showing the location
of stack traces, structure values, pointer values,
breakpoints, and so forth, even when it also displays
the contents of those addresses. The default is on. For
example, this is what a stack frame display looks like
with set print address on:
((gdb)) f
#0 set_quotes (lq=0x34c78 "<<", rq=0x34c88
">>")
at input.c:530
530 if (lquote != def_lquote)
90 Examining Data
Vue de la page 89
1 2 ... 85 86 87 88 89 90 91 92 93 94 95 ... 368 369

Commentaires sur ces manuels

Pas de commentaire

Tripp Lite SU6000RT3UHVXL podręczniki

Instrukcje obsługi i podręczniki użytkownika dla Zasilacze bezprzerwowe (UPS) Tripp Lite SU6000RT3UHVXL.
Dostarczamy 1 pdf podręczników Tripp Lite SU6000RT3UHVXL do pobrania za darmo według typów dokumentów: Arkusz Danych






Więcej produktów i instrukcji dla Zasilacze bezprzerwowe (UPS) Tripp Lite

Modele Rodzaj dokumentu
SU3000RTXLCD3U Arkusz Danych   Tripp Lite SmartOnline 100-127V 3kVA 2.7kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 3U Rack, LCD display, USB, DB9 Serial, 6 strony
SU1000XLCD Arkusz Danych   Tripp Lite SmartOnline 100-127V 1kVA 900W On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, Tower, LCD display, USB, DB9 Serial, 6 strony
SU2200XLCD Arkusz Danych   Tripp Lite SmartOnline 100-127V 2.2kVA 1.8kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, Tower, LCD display, USB, DB9 Serial, 7 strony
SU2200RTXLCD2U Arkusz Danych   Tripp Lite SmartOnline 100-127V 2.2kVA 1.8kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 2U Rack/Tower, LCD display, USB, DB9 Serial, 7 strony
SU1000RTXLCD2U Arkusz Danych   Tripp Lite SmartOnline 100-127V 1kVA 900W On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 2U Rack/Tower, LCD display, USB, DB9 Serial, 6 strony
SU10KRT3/1X Arkusz Danych   Tripp Lite SmartOnline 3-Phase In/1-Phase Out 200-240V 10kVA 7kW On-Line, Double-Conversion UPS, Extended Run, SNMP, Webcard pre-installed, 6U Rack/Tower, USB, DB9 Serial, 5 strony
SMART2200RMXL2UP Arkusz Danych   Tripp Lite 2200 VA UPS, 6 strony
SM5000RT3UTAA Arkusz Danych   Tripp Lite SM5000RT3UTAA uninterruptible power supply (UPS), 6 strony
SMART1050SLTAA Arkusz Danych   Tripp Lite SMART1050SLTAA uninterruptible power supply (UPS), 6 strony
SMX3000RT2UTAA Arkusz Danych   Tripp Lite SMX3000RT2UTAA uninterruptible power supply (UPS), 6 strony
SU1500RTXLCD2U Arkusz Danych   Tripp Lite SmartOnline 100-127V 1.5kVA 1.35kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 2U Rack/Tower, LCD display, USB, DB9 Serial, 7 strony
HT-RL15UPS Arkusz Danych   Tripp Lite HTRL15UPS, 5 strony
SU16KRTHW Arkusz Danych   Tripp Lite SmartOnline 200-240V, 16kVA 14.4kW On-Line Double-Conversion UPS, N+1, Extended Run, SNMP, Webcard, 12U Rack/Tower, USB, DB9 Serial, Hardwire, 6 strony
SU5000RT4UTF Arkusz Danych   Tripp Lite SmartOnline 208/120V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, USB, DB9 Serial, 6 strony
SU12000RT4UHW Arkusz Danych   Tripp Lite SmartOnline 240/120V or 208/120V 12kVA 8.4kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 8U, USB, DB9 Serial, Hardwire, 6 strony
SU20KX Arkusz Danych   Tripp Lite SmartOnline 20kVA 16kW Modular 3-Phase UPS System, On-line Double-Conversion UPS, SNMP, Webcard, DB9 Serial, 5 strony
SU6000RT4UTF Arkusz Danych   Tripp Lite SmartOnline 240/208/120V 6kVA 5.4kW On-Line Double-Conversion UPS, Low-Voltage Transformer, Extended Run, SNMP, Webcard, 6U Rack/Tower, Bypass Switch, 7 strony
SU6000RT4UHVHW Arkusz Danych   Tripp Lite SmartOnline 200-240V 6kVA 5.4kW On-Line Double-Conversion UPS, Extended run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial, Hardwire, 6 strony
SU3000RTXR3UHW Arkusz Danych   Tripp Lite SmartOnline 110-120V 3kVA 2.4kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 3U Rack/Tower, USB, DB9 Serial, Hardwire, 6 strony
SU40K Arkusz Danych   Tripp Lite SU40K uninterruptible power supply (UPS), 6 strony