Resuming Normal Operations
G06.24 Software Installation and Upgrade Guide—528593-005
12-9
Configure the Spooler
Confirmation dialog boxes prompt you to enter an (optional) alternative to the
default file location. The Progress bar at the bottom of the Multi-Resource Actions
dialog box tracks the success or failure of each action. (Click Action Summary to
get details on failed actions).
8. Upon successful completion of the firmware updates, select Start from the Action
list to start selected FRUs (and their associated LBUs).
9. Use the Actions dialog box or the Multi-Resource Actions dialog box to set the
FOX cluster number.
Configure the Spooler
Depending on the RVU from which you are upgrading, the spooler might require some
configuration. (Starting with the G06.00 RVU, a new control file was introduced in
T9101D46. Although it is still a type 128 file, internally it is considerably different from
the format of product versions released prior to T9101ADM). To ensure that you can
use a previous version of spooler, always back up the control files and the collector
files for that version before warm starting the new product version of spooler (see
Spooler (G06.00 through G06.19) on page 1-33).
For detailed instructions on configuring the spooler, see the Spooler Utilities Reference
Manual, Appendix H.
Starting with G06.19, the spooler SPR T9101AEY or later is installed by DSM/SCM
with CSPOOL set to HIGHPIN ON. If you want spooler to run at LOWPIN, set
HIGHPIN to OFF by using the BINDER command:
CHANGE HIGHPIN OFF IN CSPOOL
See Support Note S03006A.
Note. See Hotstuff HS02440 for information on warm starting the spooler after migration from
a product version prior to D41 to a D46 product version of the spooler if you are unable to
delete old jobs from the spooler subsystem.