NOTE:
To return the Device Addition Policy to automatic, repeat this procedure after you verify that the disk has
the correct firmware version.
Installing a disk
CAUTION:
You should only replace one disk at a time. After installing the new disk, complete the remaining
procedures in this document for this disk before you attempt to replace another disk.
1. Push in the ejector button on the disk and pull the release lever down to the full open position.
2. Insert the disk i nto the enclosure as far as it will go (1).
3. Close the release lever until it engages the ejector button, and the disk seats in the backplane (2).
4. Press in firmly on the disk to ensure it is seated pro perly.
1
2
0116a
Figure 39 Installing a disk
Verifyin
g proper operation
After rep
lacing the disk, check the following to verify that the disk is operating normally:
NOTE:
It may take up to 10 minutes for the c omponent to display good status.
• Check the disk status ind icators (Figure 34).
•Activityindicator(1)shouldbeonorflashing
• O nline indicator (2) should be on or flashing
• Fault indicator (3) should be off
• Check the following using HP Command View EVA:
• N avigate back to the component and check the operational state. It should be
.
• Ensure the d isk is running the correct firmware. Record the Model number and the Firmware
version of the disk (Figure 40). Check the firmware version against the supported disk firmware
in the HP StorageWorks Enterprise Virtual Array release notes.SeetheHP StorageWorks
Enterprise Virtual Array upgrading disk drive firmware read me first for installation instructions.
You c an download these documents from the following website: