Hp 3Gb SAS Switch for HP BladeSystem c-Class Manuel d'utilisateur Page 76

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 86
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 75
2. Assign the zone group to the server device bay.
This example shows how to assign ozone group zone5 to server device bay 5.
=> sw local startupdate
Success
=> bb 5 add zg=zone5
Success
=> sw local saveupdate
Success
3. [Optional] Verify that the zone group was assigned as intended.
For example, use one of the following commands:
=> bb all show detail
=> sw local zg all show detail
The display of this example is abbreviated, retaining key details. Zone group zone5 is now
assigned to server device bay 5.
=> sw local zg all show detail
Blade Enclosure at BottomC7000
Switch: Local
Zone Group: zone1
Zoned Storage Enclosure Bay: 71:1:1
Zoned Storage Enclosure Bay: 71:1:2
Zoned Storage Enclosure Bay: 71:1:3
Zoned Storage Enclosure Bay: 71:1:4
Zoned Storage Enclosure Bay: 71:1:5
Zoned Storage Enclosure Bay: 71:1:6
Zoned Storage Enclosure Bay: 71:1:7
Assigned Blade Bay: 1
Zone Group: zone2
Zoned Storage Enclosure Bay: 71:1:8
Zoned Storage Enclosure Bay: 71:1:9
Zoned Storage Enclosure Bay: 71:1:10
Zoned Storage Enclosure Bay: 71:1:11
Zoned Storage Enclosure Bay: 71:1:12
Zoned Storage Enclosure Bay: 71:1:13
Zoned Storage Enclosure Bay: 71:1:14
Assigned Blade Bay: 2
-
-
-
Zone Group: zone5
Zoned Storage Enclosure Bay: 71:1:29
Zoned Storage Enclosure Bay: 71:1:30
Zoned Storage Enclosure Bay: 71:1:31
Zoned Storage Enclosure Bay: 71:1:32
Zoned Storage Enclosure Bay: 71:1:33
Zoned Storage Enclosure Bay: 71:1:34
Zoned Storage Enclosure Bay: 71:1:35
Assigned Blade Bay: 5
76 Performing common tasks