Vue de la page 34
4.9
Run Time Error Messages
3PAR VAAI Plug-in 1.1.0 for VMware vSphere 4.1 Users Guide
MESSAGE
3parvaai:ERR InquiryC0Data(ScsiDeviceStatus = %s, ScsiHostStatus = %s,
ScsiPlugInStatus = %s)
DESCRIPTION
An inquiry into the customer page C0 data has failed. The vmk_ScsiDeviceStatus is the status
reported by the target/LUN itself.
ScsiDeviceStatus indicates the device status.
vmk_ScsiHostStatus is a status value from the driver/hba.
vmk_ScsiPluginStatus is a status value returned from the MP plug-in that was
processing the I/O command.
SUGGESTED ACTION
If ScsiDeviceStatus is not set to 0, check the 3PAR InServ log for related information.
Otherwise check the
/var/log/vmkernel log file for additional details that might be useful
in resolving this problem.
Vue de la page 34