10 - 7
Setting a transmission window
The transmission window establishes a period of availability for all Storage Mirroring transmissions.
1. Select the Window option in the Limit Type box.
2. Mark the Enable Transmission Window check box to enable the transmission window feature.
3. Define the window of availability for Storage Mirroring transmission by setting the Open window time and Close window
time
settings. The time fields are formatted for any AM or PM time.
4. If no additional transmission options need to be set, establish the connection by clicking Connect.
NOTE: Setting a transmission window by itself is not sufficient to start a transmission. You still need to set a start
criteria.