Hp StorageWorks EVA Controller HSG V8.8 Software Manuel d'utilisateur Page 65

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 150
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 64
Interpreting Agent Email Messages
65Command Console V2.5 User Guide
The details about the failure of the LUN follow in parentheses, in the format:
virtual_disk:state
where virtual_disk is the unit number of the virtual disk and state is any of the
following:
0—Good.
1—Reduced.
2—Reconstructing.
3—Failed.
In this example, logical unit D100 failed.
In most cases, the RaidManager sends at least two consecutive email messages.
The first message is always in the form:
---------------
From RaidManager Tue Oct 6 16:09:37 1998
Date: Tue, 6 Oct 1998 16:09:37 -0500 (EST)
From: RaidManager
This is an automatic message from your StorageWorks
RAID Agent, steamd. The following message was just received.
Please check your syslog files and RAID box!
Hostname: Suncity
WARNING: - A RAID system change has been detected: Suncity HSG80
OVRL=1 (SP_MONITOR: MonitorSubsys)
End Of Automatic Message.
-------------
The text of the second message will be similar to the following (depending on the
error):
---------
From RaidManager Tue Oct 6 16:09:37 1998
Date: Tue, 6 Oct 1998 16:09:37 -0500 (EST)
From: RaidManager
This is an automatic message from your StorageWorks
RAID Agent, steamd. The following message was just received.
Please check your syslog files and RAID box!
Hostname: Suncity
WARNING: - Suncity HSG80 12000000000 HSG80 disks(disk10200:1
disk10300:2) (SP_MONITOR: MonitorSubsys)
End Of Automatic Message.
-------------
Vue de la page 64
1 2 ... 60 61 62 63 64 65 66 67 68 69 70 ... 149 150

Commentaires sur ces manuels

Pas de commentaire