Maximum
character
length
Description
#2
Parameter
#1
Y
5
(The
maximum
value is
86400.)
Specify the timeout value for
configuration check processing at the
remote site as a value between 0 and
86400 (in seconds).
If you specify 0, this processing does
not time out. If you omit this
specification, 3600 is assumed.
Only parameter values in sections that
are considered to be for the remote site
are used.
As a rule, set this value to roughly 1.5
times the period required to run the
backup command for the site at which
this parameter is specified when the
-cascade option is not specified
(assuming all of the other options are
the same).
PREBACKUP_TIMEOUT
Y
5
(The
maximum
value is
86400.)
Specify the timeout value for the pair
resynchronization processing at the
remote site as a value between 0 and
86400 (in seconds).
If you specify 0, this processing does
not time out. If you omit this
specification, 3600 is assumed.
Only parameter values in sections that
are considered to be for the remote site
are used.
As a rule, set this value to roughly 1.5
times the period required to run the
backup command for the site at which
this parameter is specified, when the
-cascade option is not specified
(assuming all of the other options are
the same).
PRESPLIT_TIMEOUT