Vue de la page 28
Figure 13 Journal St atus
Array mapping
To correctly map the ACP and CHIP pairs for your specic array, use the information in the following
tables:
Table 4 lists
1 AC P pair for disk array XP48/128.
NOTE:
The cards are lettered A-M, omitting I.
Table 4 XP48/128 (1 ACP Pair)
B, L
ACP Pair 1 ACP B = 0; L = 4
C, G CHIP Pair 1
Chip C = 0; G = 4
D, J
CHIP Pair 2
Chip D = 1; J = 5
F, K
CHIP Pair 3
Chip F = 2; K = 6
Table 5 lists the 2 ACP pairs for disk array XP48/128.
NOTE:
The cards are lettered A-M, omitting I.
Table 5 XP 4
8/128 (2 ACP Pairs)
B, L
ACP Pair 1 ACP B = 0; L = 4
F, K
ACP Pair 2 ACP F = 1; K =
5
C, G CHIP Pair
1
Chip C = 0; G = 4
D, J
CHIP Pair 2
Chip D = 1; J = 5
Table 6 lists the ACP and CHIP pairs for XP256/512/1024.
NOTE:
The card
s are lettered A-Z, omitting I and O; with 12 cards on the back (A-M) and 12 on the front (N-Z).