HP StorageWorks XP24000 Auto LUN Software User's Guide Part number: T5215–96001 First edition: June 2007

Page 2 - Description

Figure 1 Performance Management Process Flow Diagram Overview of HP StorageWorks XP Auto LUN Software 10

Page 3 - Contents

2 About Auto LUN Operations Components To use Auto LUN, you need: • the storage system • the Auto LUN program product (Performance Monitor is r

Page 4

group or volume usage varies only slightly, or for cases in which overall DKP or DRR usage is relatively high. • From an open-system host, users can

Page 5 - Figures

To find fast hard disk drives, display the Auto LUN window and check classes (Figure 4 on page 13). Classes indicate disk access speed for parity group

Page 6

Notes: When you use Auto LUN for the first time, you must reserve volumes for migration destinations in advance. These reserved volumes are marked wit

Page 7 - About this Guide

The Auto LUN operation consists of two steps: • Copy thedataonthe Auto LUNsourcevolumetothe Auto LUN target volume(see Figure 7 on page 15). • Transf

Page 8

Old Target Volume Old Source Volume Hosts cannot access device. Hosts can access device. LDEV ID = 0x123 LDEV ID = 0x321 Reserved Figure 8 Data Flow

Page 9 - XP Auto LUN Software

TrueCopy for Mainframe: If the status of a TrueCopy for Mainframe volume is suspended or simplex, the volume can be used as a source volume. If not,

Page 10

• TrueCopy for Mainframe operation that changes the volume status to something other than suspended or simplex. • Continuous Access operation that c

Page 11 - 2 About Auto LUN Operations

can be executed concurrently changes depending on the number of differential tables that Auto LUN can use, and depending on the emulation types and si

Page 12 - Manual Volum

Legal and notice information © Copyright 2007 Hewlett-Packard Development Company, L.P. Confidential computer software. Valid license from HP required

Page 13

• ShadowImage for Mainframe • Compatible FlashCopy Table 4 The capacity of migrated volume and the estimated delay in the copying speed Capacity of

Page 14 - About Auto LUN Operations

of differential tables and pair tables needed for migrating a mainframe volume, see “Calculating Differential Tables Required for Mainframe Volume Mig

Page 15

The following table shows the number of the control cylinders according to the emulation types. Table 5 The Number of the Control Cylinders According

Page 16 - Auto LUN

Table6TheTotalNumberoftheDifferentialTablesPerMigrationPlan Emulation Type Expression OPEN-3 Total number of the differential tables per migration pla

Page 17 - Caution:

Table 7 The Number of the Control Cylinders According to the Emulation Types Emulation Type Number of the Control Cylinders OPEN-3 8 (5,760KB) OPEN-8

Page 18

3PreparingforAutoLUN Operations System Requirements To use Auto LUN, you need: • Storage system • Auto LUN software (Performance Monitor is req

Page 19 - Copy Threshold Option

26 Preparing for Auto LUN Operations

Page 20

4UsingtheAutoLUNGUI Using the Auto LUN Windows Auto LUN can be used to balance workloads among hard disk drives and thus remove bottlenecks from the s

Page 21

Figure 13 The Manual Plan Window of the Auto LUN The Manual Plan window displays the following: • Monitoring Term: Displays the monitoring period spe

Page 22

• indicates a RAID-6 parity group. The HDD class for this parity group is C. • indicates a RAID-6 parity group. The HDD class for this parity group i

Page 23

Contents AboutthisGuide ... 7 IntendedAudience... 7 RelatedDocumentation...

Page 24 - Cylinders

indicatesthe status of thevolume. Thenumberonthe left of the first colon (:) from the left is the LDKC number. The number on the left of the second co

Page 25 - Operations

Indicates the volume ID. The number on the left of the first colon (:) from the left is the LDKC number. The number on the left of the second colon (:)

Page 26

• An estimated usage rate for the parity group after a proposed volume migration. If you specify an external volume as a source volume, Auto LUN cann

Page 27 - 4UsingtheAutoLUNGUI

• RAID indicates the RAID type. • PG indicates the parity group ID or the external volume group ID. The number before the hyphen (-) is the frame nu

Page 28 - Using the Auto LUN GUI

Figure 18 The Attribute Window of the Auto LUN The Attribute window displays the following information: • Monitoring Term displays the monitoring per

Page 29

right of an icon, the icon represents the parity group 1-3. If the text 1-3[1-4] appears on the right of an icon, the icon represents two parity group

Page 30

indicates a normal volume that can be migrated. If you change the attribute of this volume to a reserved volume ( ), this volume can be used as a mig

Page 31

When you select an external volume group in the tree, the list displays information about external volumes (that is volumes in the external volume gro

Page 32

Figure23TheHistoryWindowoftheAutoLUN Note:Auto Migration History will be supported in a future release. The History window displays the following info

Page 33

•The Source[Parity Gr.] and Target[Parity Gr.] columns also display the information about external volume group migration, though these groups are n

Page 34

CallingHPTechnicalSupport ... 49 AAcronymsandAbbreviations ... 51 Index ...

Page 35

40 Using the Auto LUN GUI

Page 36

5AutoLUN Operations Starting Auto LUN To start Auto LUN, take the following steps: 1. Ensure that the Remote Web Console main window is in Modify

Page 37 - HistoryWindowofAutoLUN

5. Select the Apply button. The settings in the window are applied to the storage system. The specified volume is reserved as a migration destination.

Page 38

A new migration plan, consisting of the specified source and target volumes, is added to the list. The new migration plan is displayed in blue. Note: T

Page 39

Table 9 Messages in the Migration Logs (displayed in the Action column) Message Meaning Migration Started The migration operation started. Migration C

Page 40

6 Using RAID Manager for Manual Volume Migration In the environment where Auto LUN is installed on the storage system, users can use RAID Manager to p

Page 41 - 5AutoLUN Operations

SMPL Pairsplit -S Pairsplit -S PSUS Pairsplit -S Paircreate PSUE COPY Migration succeeded Migration Failed Figure 25 Status Transition Chart of a

Page 42 - Migrating Volumes Manually

Error Code Cause Measure 2301 Auto LUN is not installed on the storage system. Install Auto LUN, and the perform the volume migration. 2306 The LBA si

Page 43

Error Code Cause Measure 234B The migration target volume is already specified as thesourcevolumeofAuto LUN. Release the volume from Auto LUN, and then

Page 44 - Meaning

7 Troubleshooting This chapter gives troubleshooting information on Auto LUN. For troubleshooting information on Remote Web Console, see the following

Page 45 - Volume Migration

...Figures 1 PerformanceManagementProcessFlowDiagram... 10 2 AnExampleofMigrationPlansDisplayedinth

Page 47 - Measure

A Acronyms and Abbreviations Table 11 Acronyms and Abbreviations ACP array control processor CU controlunit (logicalcontrol unit) DASD direct-access s

Page 48

52 Acronyms and Abbreviations

Page 49 - 7 Troubleshooting

Index A audience, 7 Auto LUN system requirements,25 C class,13 conventions document, 7 storage capacity values, 7 D document conventions, 7 related do

Page 50 - Troubleshooting

...Tables 1 DocumentConventions ... 7 2 Non-Cascade Volumes and Auto LUN Source Volumes .. ... ... ... ...

Page 51 - A Acronyms and Abbreviations

About this Guide This user's guide describes and provides instructions for using the Auto LUN software. The term storage system in this guide ref

Page 52 - Acronyms and Abbreviations

• 1 TB (terabyte) = 1,0004 bytes HP XP storage systems use the following values to calculate logical storage capacity values (logical devices): • 1K

Page 53

1 Overview of HP StorageWorks XP Auto LUN Software Auto LUN lets you balance workload among hard disk drives, volumes (LUs) and processors to remove b