Models
LP350, LP400, LP450
Triplex Ceramic
Plunger Pump
Operating Instructions/
Repair and Service
Manual
Contents:
Installation Instructions: page 2
Pump Specifications: pages 3-5
Exploded View: page 6
Parts List/Kits/Torque Specs: page 7
Trouble Shooting Chart: page 8
Spare Parts List: page 8
Repair Instructions: page 9-11
Dimensions: back page
Warranty Information: back page
Updated 2/02
Vue de la page 0
1 2 3 4 5 6 ... 11 12

Résumé du contenu

Page 1 - LP350, LP400, LP450

ModelsLP350, LP400, LP450Triplex CeramicPlunger PumpOperating Instructions/Repair and ServiceManualContents:Installation Instructions: page 2Pump Spec

Page 2 - INSTALLATION INSTRUCTIONS

109) Remove seal case (37) fromseal sleeve (35).10) Check plunger surface (25and 29B) for wear and pit-ting. If none is found, pro-ceed to step twelv

Page 3 - Model LP350

11DISASSEMBLY OF CRANKCASE1) Remove valve casing (43) and plunger pipe (29B), drain oil.2) Screw off gear cover (4) and bearing cover (14).3) Remove c

Page 4 - Model LP400

GIANT INDUSTRIES LIMITED WARRANTYGiant Industries, Inc. pumps and accessories are warranted by the manufacturer to be free fromdefects in workmanship

Page 5 - Model LP450

2INSTALLATION INSTRUCTIONS4. Use of a dampener is necessary to minimizepulsation at drive elements, plumbing, connec-tions, and other system areas.

Page 6

3SpecificationsModel LP350Volume... Up to 22.6 GPMDisc

Page 7 - TORQUE SPECIFICATIONS

4SpecificationsModel LP400Volume... Up to 15.1 GPMDisc

Page 8 - PUMP SYSTEM MALFUNCTION

5SpecificationsModel LP450Volume... Up to 19.7 GPMDisc

Page 9 - SEAL AND PLUNGER REPLACEMENT

6LP350, LP400, LP450 - EXPLODED VIEW

Page 10 - (LP400 only)

7ITEM # PART # DESCRIPTION QTY1 07759 Crankcase 12 13000 Oil filler plug assy. 14 06085 Crankcase Cover 15 07104 O-ring, Crankcase cover 16 07186 Oil

Page 11

8PUMP SYSTEM MALFUNCTIONMALFUNCTION CAUSE REMEDYThe Pressure and/ Worn packing seals Replace packing sealsor the Delivery Broken valve spring Replace

Page 12 - (inches)

9REPAIR INSTRUCTION - LP350, LP400, LP450TO CHECK VALVES4) Inspect valve seats (46A) and valve plates (46B) for damageand replace if needed. Check val