Control panel message Description Recommended action
90B-Fan Failure The system has detected that a cooling fan is
not operating correctly.
1. Reseat fan.
2. Reseat fan cable.
3. Replace fan.
90D-System Temperature Thermal shutdown occurred. The system BIOS
has detected your machine was previously shut
down to avoid overheating. Overheating may
occur if the cooling vents are blocked or the
operating temperature exceeds the system
specications. The machine should return to
normal operation once the situation is resolved.
Make sure system has proper airow.
90E-Power Supply Fan Not detected Power supply fan is not connected or may have
malfunctioned.
1. Reseat power supply fan.
2. Reseat fan cable.
3. Replace power supply fan.
910–Filter Warning Airow lter is dirty. Replace the airow lter.
Interpreting system validation diagnostic front panel LEDs and
audible codes
During the system validation phase that occurs at system startup, the BIOS validates the functionality of the
following subsystems and conditions:
AC adapter
System board power
Processor failure
BIOS corruption
Memory failure
Graphics failure
System board failure
BIOS authentication failure
If an error is detected, specic patterns of long and short blinks, accompanied by long and short beeps (where
applicable) are used to identify the error. These patterns will make up a two part code:
Major – the category of the error
Minor – the specic error within the category
NOTE: Single beep/blink codes are not used.
Number of long beeps/blinks Error category
1 Not used
2 BIOS
3 Hardware
Interpreting system validation diagnostic front panel LEDs and audible codes 115