Table 3-18 Set API Password (continued)
Schema Request
?api=accessibility&schema=setApiPassword
Response
?api=common&rschema=default
Figure 3-17 Set API password, request payload example
Figure 3-18 Set API password, success response example
3.4.2 Block Embedded Capture UI
Table 3-19 Block device
?api=accessibility&method=block
GET Description Disables the Embedded Capture Home screen button on the control panel. This is
highly recommended before performing administration tasks that need to change
workflows structure and may affect the user scanning.
Payload IN
OUT If 200, XML response with code 0.
If 400, XML response with error code.
Response Code 200 OK – success
400 Bad request:
Error code –10: Device is busy.
Error code –12: Unexpected error.
401 Unauthorized access – if basic authentication fails
500 Internal Server Error – if too many requests are active. Retry recommended.
Schema Request
Response
?api=common&rschema=default
Section 3.4 Accessibility services 23