To identify the error code in the log file, open the RAID Manager log file, and find the error code.
Example: 11:06:03-37897-10413- SSB = 2E31, 3703
Error codes appear on the right of the equal symbol (=). The alphanumeric characters on the left
of the comma(,) indicates SSB1 (for example, 2E31), and on the right of the comma (,) indicates
SSB2 (for example, 3703).
The following tables describe the RAID Manager error codes for Continuous Access Journal.
RAID Manager error codes for Cnt Ac-J: SSB1 = 2E31, B901, B9E0, B9E1,
B9E2, B9E4, D004
DescriptionError code (SSB2)
A request of Cnt Ac-J Pairresync to change the pair status from HLDE to HOLD was rejected
because the PIN data was existed in the journal volume.
3703
A request of Cnt Ac-J Paircreate was rejected because the emulation types of the specified master
journal and of the restore journal were different.
3704
A request of Cnt Ac-J Paircreate or Cnt Ac-J Pairresync for delta resync was rejected because the
version of the secondary system did not support the corresponding command.
3705
A request of Cnt Ac-J Paircreate for delta resync was rejected because the specified P-VOL was
used as the S-VOL of Continuous Access Synchronous, and the pair status was not PAIR.
3706
A request of Cnt Ac-J Pairresync for delta resync was rejected because of the one of following
reasons.
3707
The specified P-VOL was the P-VOL of Continuous Access Synchronous, and the Cnt Ac-J pair
status was not PAIR.
The specified P-VOL was the S-VOL of Continuous Access Synchronous, and the Cnt Ac-J pair
status was not SSWS.
The Cnt Ac-J pair cannot be created because the specified P-VOL was being shredded.3708
A request of Cnt Ac-J Paircreate or Cnt Ac-J Pairresync for delta resync was rejected because the
specifying of the restore journal was incorrect.
3709
The Cnt Ac-J pair cannot be resynchronized (DELTAJNL parameter specifying), because the
specified P-VOL is not in the either of HOLD or HOLDTRNS status. Or, the Cnt Ac-J pair cannot
370B
be resynchronized (ALLJNL parameter specifying), because the specified P-VOL is not in the either
of HOLD, HOLDTRANS, or NODELTA status.
A request of Paircreate or Pairresync for Cnt Ac-J pair or Cnt Ac-J pair for delta resync was
rejected because the status of the specified master journal or restore journal could not be transited,
or the status transition was in progress.
370C
A request by Cnt Ac-J Paircreate or Cnt Ac-J Pairresync was rejected because the Continuous
Access Synchronous pair was either in the status other than suspending or was not used in the
2DC configuration.
371C
The journal was registered when 2DC Cascade set to Enable in the Edit Journal Volumes dialog
box. In the 2DC Cascade configuration, the Cnt Ac-J pair cannot be created when the Continuous
371D
Access Synchronous is already registered. The 3DC multi-target configuration also cannot be
created.
A request by Cnt Ac-J Paircreate or Pairresync was rejected because the journal volume in the
specified master journal was blocked.
3720
The Cnt Ac-J pair cannot be created because the version of the DKCMAIN microcode on the
remote storage system does not support the LUSE volume.
3723
The Cnt Ac-J pair cannot be created because the volume specified as the P-VOL was the system
disk.
3726
A request of Cnt Ac-J Paircreate was rejected because it was connected with the old model and
the specified volume was unsupported.
3728