Replacing, moving, or adding hard drives 35
b.
Recreate the partitions.
c. Restore all data from backup.
To minimize the risk of data loss that is caused by compromised fault tolerance, make frequent backups of
all logical volumes.
Replacing hard drives
The most common reason for replacing a hard drive is that it has failed. However, another reason is to
gradually increase the storage capacity of the entire system.
If you insert a hot-pluggable drive into a drive bay while the system power is on, all disk activity in the
array pauses for a second or two while the new drive is spinning up. When the drive has achieved its
normal spin rate, data recovery to the replacement drive begins automatically (as indicated by the
blinking Online/Activity LED on the replacement drive) if the array is in a fault-tolerant configuration.
If you replace a drive belonging to a fault-tolerant configuration while the system power is off, a POST
message appears when the system is next powered up. This message prompts you to press the F1 key to
start automatic data recovery. If you do not enable automatic data recovery, the logical volume remains
in a ready-to-recover condition and the same POST message appears whenever the system is restarted.
Factors to consider before replacing hard drives
Before replacing a degraded drive:
Open Systems Insight Manager, and inspect the Error Counter window for each physical drive in the
same array to confirm that no other drives have any errors. (For details, refer to the Systems Insight
Manager documentation on the Management CD.)
Be sure that the array has a current, valid backup.
Confirm that the replacement drive is of the same type (SAS or SATA) as the degraded drive.
Use replacement drives that have a capacity at least as great as that of the smallest drive in the
array. The controller immediately fails drives that have insufficient capacity.
In systems that use external data storage, be sure that the server is the first unit to be powered down and
the last to be powered back up. Taking this precaution ensures that the system does not erroneously mark
the drives as failed when the server is powered up.
To minimize the likelihood of fatal system errors, take these precautions when removing failed drives:
Do not remove a degraded drive if any other drive in the array is offline (the Online/Activity LED is
off). In this situation, no other drive in the array can be removed without data loss.
The following cases are exceptions:
o When RAID 1+0 is used, drives are mirrored in pairs. Several drives can be in a failed condition
simultaneously (and they can all be replaced simultaneously) without data loss, as long as no two
failed drives belong to the same mirrored pair.
o When RAID 6 (ADG) is used, two drives can fail simultaneously (and be replaced simultaneously)
without data loss.
o If the offline drive is a spare, the degraded drive can be replaced.
Vue de la page 34
1 2 ... 30 31 32 33 34 35 36 37 38 39 40 ... 54 55

Commentaires sur ces manuels

Pas de commentaire

MULTIQUIP MQ Power Whisperwatt 60HZ Generator DCA150USJ2 podręczniki

Instrukcje obsługi i podręczniki użytkownika dla Do samochodu MULTIQUIP MQ Power Whisperwatt 60HZ Generator DCA150USJ2.
Dostarczamy 1 pdf podręczników MULTIQUIP MQ Power Whisperwatt 60HZ Generator DCA150USJ2 do pobrania za darmo według typów dokumentów: Instrukcja Użytkownika


Spis treści

MODEL DCA150USJ2

1

PROPOSITION 65 WARNING

2

REPORTING SAFETY DEFECTS

3

DCA150USJ2 60 Hz

4

Generator

4

PARTS ORDERING PROCEDURES

5

SAFETY INFORMATION

10

SPECIFICATIONS

12

DIMENSIONS

13

INSTALLATION

14

GENERAL INFORMATION

16

MAJOR COMPONENTS

17

DIAGNOSTIC DISPLAY

18

USE DEFAULTS

28

CUSTOM SETUP

28

AUTOMATIC SCAN OFF

28

SOFTWARE

32

MURPHY: X.XX

32

INCREASE

35

ENGINE OPERATING PANEL

37



38



39



39



40

Over Current Relay

40

LOAD APPLICATION

41



42



42

Generator Amperage

42



43



43

AC Ammeter Gauge Reading

43



44

INSPECTION/SETUP

46

GENERATOR START-UP PROCEDURE

50



52



52

MAINTENANCE

53

TRAILER MAINTENANCE

56

TRAILER WIRING DIAGRAM

60

GENERATOR WIRING DIAGRAM

61

ENGINE WIRING DIAGRAM

62

TROUBLESHOOTING (GENERATOR)

63



65

SAMPLE PARTS LIST

66

NO. Column

66

PART NO. Column

66

QTY. Column

66

REMARKS Column

66

SUGGESTED SPARE PARTS

67

GENERATOR ASSY

68

CONTROL BOX ASSY

70

ENGINE AND RADIATOR ASSY

74

OUTPUT TERMINAL ASSY

78

BATTERY ASSY

80

MUFFLER ASSY

82

FUEL TANK ASSY

84

ENCLOSURE (1) ASSY

86

ENCLOSURE (2) ASSY

90

RUBBER SEALS ASSY

94

NAMEPLATE AND DECALS ASSY

96

HERE’S HOW TO GET HELP

102





Więcej produktów i instrukcji dla Do samochodu MULTIQUIP

Modele Rodzaj dokumentu
Control Box Replacement LS60TD Instrukcja Użytkownika   Multiquip Control Box Replacement LS60TD User Manual, 8 strony
Trash Pump QP3TY Instrukcja Użytkownika   Multiquip Trash Pump QP3TY User Manual, 56 strony
60HZ GENERATOR DCA25SSIU3 Instrukcja Użytkownika   Multiquip 60HZ GENERATOR DCA25SSIU3 User Manual, 76 strony
Tamping Rammer Mikasa MT-86D Instrukcja Użytkownika   Multiquip Tamping Rammer Mikasa MT-86D User Manual, 50 strony