Domain management 43
The VC-FC module generates connUnitPortStatusChange traps based on changes to the connUnitPortStatus
element of the FA-MIB. The following table shows the mapping of connUnitPortStatusChange trap
severities to the VC Domain MIB's trap severity definitions.
connUnitPortStatus value Severity
unknown INFO
unused INFO
ready NORMAL
warning WARNING
failure CRITICAL
nonparticipating INFO
initializing INFO
bypass INFO
ols MAJOR
other INFO
VC Module MIB traps
The following table lists traps in the VC Module MIB.
Trap name Trap data Description
vcModRoleChange moduleRole The VCM role of the module has changed.
vcModInputUtilizationUp port identification
The input line utilization on a port has exceeded its
high-water mark for longer than 30 seconds. port is
the index of the affected port in
.
vcModInputUtilizationDown port identification
The input line utilization on a port has dropped below
its low-water mark for longer than 30 seconds. port
is the index of the affected port in
.
vcModOutputUtilizationUp port identification
The output line utilization on a port has exceeded its
high-water mark for longer than 30 seconds. port is
the index of the affected port in
.
vcModOutputUtilizationDow
n
port identification
The output line utilization on a port has dropped
below its low-water mark for longer than 30 seconds.
is the index of the affected port in
.
vcModInputErrorsUp port identification
ifInErrors
The input error count on a port has exceeded its high-
water mark for longer than the error averaging period.
is the index of the affected port in
.
vcModInputErrorsDown port identification
ifInErrors
The input error count on a port has dropped below its
low-water mark for longer than the error averaging
period. port is the index of the affected port in
.
vcModOutputErrorsUp port identification
ifOutErrors
The output error count on a port has exceeded its high-
water mark for longer than the threshold averaging
period. port is the index of the affected port in
.
vcModOutputErrorsDown port identification
ifOutErrors
The output error count on a port has dropped below
its low-water mark for longer than 30 seconds. port
is the index of the affected port in
.
Commentaires sur ces manuels