Hp Integrity BL870c i2 Server-Blade Manuel d'utilisateur Page 49

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 117
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 48
Command line 49
Item Description
Name (required)
The new name of the server profile
EFIState
(required)
Specifies the presence or absence of EFI state information
Examples
->set profile MyProfile Name=MyNewProfileName
Changes the name of a server profile
->set profile Profile1 EFIState=absent
Removes EFI partition block information from a profile
Item Description
show profile
Display all server profiles that exist in the domain and a summary of the
associated Ethernet, iSCSI, FC, and FCoE connections. To view detailed
information for the connections, use the show enet-connection,show
iscsi-connection, show fc-connection, and show fcoe-
connection
commands, respectively.
Syntax
show profile [<ProfileName> | *]
Parameter
ProfileName
(optional)
The name of an existing profile in the VC domain. "*" displays all the existing
profiles. If not specified, a summary of all the profiles appears.
Examples
->show profile
Displays a summary listing of all server profiles
->show profile *
Displays detailed information for all profiles
->show profile MyProfile
Displays detailed information for a specific profile
Item Description
unassign profile
Unassign a server profile from a device bay.
Syntax
unassign profile <ProfileName>
Parameter
ProfileName
(required)
The name of a server profile that is currently assigned to a device bay
Example
->unassign profile MyProfile1
Unassigns a server profile from a device bay
server
Manage server blades.
Supported actions: help, poweroff, poweron, reboot, show
Item Description
poweroff server
Power off one or more physical servers.
Vue de la page 48
1 2 ... 44 45 46 47 48 49 50 51 52 53 54 ... 116 117

Commentaires sur ces manuels

Pas de commentaire