5344 Tape Drive Installation and User’s Guide—546011-001
B-1
B
Configuring the Tape Drive for the
NonStop BladeSystem Server
This section covers:
Configuration Overview
NonStop BladeSystems can connect to the tape drive by means of a CLIM
(CLuster I/O Module). Each CLIM provides access to the tape drive through a
Fibre Channel ports.
For more information on connecting tape drives to the CLIM, see the NonStop
CLuster I/O Module (CLIM) Installation and Configuration Guide.
For a list of tape drives supported for use with Blades-series servers, see the
NonStop BladeSystem Installation Manual.
Adding the Tape Drive
Issue an SCF ADD TAPE command to configure the tape drive. This is an
example:
-> ADD TAPE $5344, SENDTO STORAGE, CLIM C1002531, LUN 1
You can specify backup and primary CPUs if you need to balance the
processing load to other CPUs.
Configuration Overview B-1
Adding the Tape Drive B-1
Start the Tape Drive B-2
Verify the Tape Configuration B-2
Troubleshoot the Tape Configuration B-3