Chapter 3 Installing Fans and Power Supplies
23
Figure 3-2. Removing the 120 mm Fans
Installing the 120 mm Fans
Follow these steps to install a 120 mm fan:
1. Slide the server out of the rack far enough to expose the fan-access door on
the top of the chassis.
2. Unscrew the thumbscrew on the front of the fan-access door and lift the
door open.
3. Slide the new fan into place, with the connector oriented to engage the
socket inside of the fan enclosure.
4. Push the fan assembly firmly into the enclosure to seat the connector.
5. Close the fan-access door and tighten the thumbscrew.
6. Slide the chassis back into the rack.
Vue de la page 30