Switch Command Interface (SWCI)
ServerNet Nomadic Disk User’s Guide425485-001
6-42
Switch Protocol Error Messages
Cause. The part number/revision field of an SCC or the switch card FIR string read
from the switch module is not present or is incorrectly specified.
Effect. SWCI does not work properly.
Recovery. Do the following:
1. Check the configuration of the switch module device and reconfigure if necessary.
2. Check the version of SWCI installed.
3. Power the switch module device off then back on again.
Cause. The FRU part number field header of an SCC or the switch card FIR string read
from the switch module is incorrectly specified.
Effect. SWCI does not work properly.
Recovery. Do the following:
1. Check the configuration of the switch module device and reconfigure if necessary.
2. Check the version of SWCI installed.
3. Power the switch module device off then back on again.
Cause. The FRU revision field header of an SCC or the switch card FIR string read
from the switch module is incorrectly specified.
Effect. SWCI does not work properly.
Recovery. Do the following:
1. Check the configuration of the switch module device and reconfigure if necessary.
2. Check the version of SWCI installed.
3. Power the switch module device off then back on again.
***PROTOCOL ERROR*** Bad part number/revision field in SCC/SC
FIR string.
***PROTOCOL ERROR*** Bad FRU part number header in SCC/SC FIR
string.
***PROTOCOL ERROR*** Bad FRU revision header in SCC/SC FIR
string.