Overview and Hardware/Software Requirements for
Mid-Range Silo Media Manager (MSMM)
Mid-Range Silo Media Manager Installation and Users Guide541530-003
1-2
MSMM Connection Configuration Overview
MSMM Connection Configuration Overview
In order for the MSMM software to control the tape library, a tape library control path
must be configured from the HP NonStop S-series system to the tape library. The
system controls the movements of the tape librarys robotic arm. In this case the
system is a HP NonStop S-series.
HP NonStop S-series Systems
The tape library control path can be configured to run on one of the following
controllers:
Processor Multifunction Controller (PMF CRU)
ServerNet/DA SCSI ServerNet Addressable Controller (S-SAC).
For configuration examples and command syntax, see the SCF Reference Manual for
the Storage Subsystem. The tape library control path is configured in SCF using the
"ADD SCSI" command.
Example:
ADD SCSI $SL500, SENDTO STORAGE, PRIMARYLOCATION
(1,1,51),PRIMARYSAC 1, SCSIID 5, PRIMARYCPU 1, BACKUPCPU 0
The tape library control path physically connects from the PMFC or ServerNet/DA S-
SAC via a copper cable to the tape library. The cable connection should not exceed
seventy-five feet (75 ft.) or twenty-three meters (23m).
Note. The preceding example is for the tape library control path (robotic arm) on a PMFC.