Troubleshooting 103
Node Interleaving disabled - Invalid memory configuration
Description: Each node must have the same memory configuration to enable
interleaving.
Action: Populate each node with the same memory configuration and enable
interleaving in RBSU.
There must be a first DIMM in pair if second DIMM in pair is
populated. Second DIMM in pair ignored.
Description: The first DIMM socket in the pair is not populated. The second
DIMM in the pair is not recognized or used.
Action: Populate the DIMM socket.
Unsupported DIMM(s) found in system. - DIMM(s) may not be
used
Description: Unsupported memory types found in system.
Action: Refer to the applicable server user guide memory requirements and
replace with supported DIMMs.
1610-Temperature Violation Detected. - Waiting 5 Minutes for
System to Cool
...Press Esc key to resume booting without waiting for the system to cool.
WARNING: Pressing Esc is NOT recommended as the system may shutdown unexpectedly.
Audible Beeps: None
Possible Cause: The ambient system temperature exceeded acceptable levels.
Action: Lower the room temperature.