Specifications 110
Specifications
Environmental specifications
Specification Value
Temperature range*
Operating
10
°
C to 35
°
C (50
°
F to 95
°
F)
Shipping
-40°C to 70°C (-40°F to 158°F)
Maximum wet bulb temperature
28°C (82.4°F)
Relative humidity
(noncondensing)**
Operating
10% to 90%
Non-operating
5% to 95%
* All temperature ratings shown are for sea level. An altitude derating of 1°C per 300 m (1.8°F per 1,000 ft) to 3048
m (10,000 ft) is applicable. No direct sunlight allowed.
** Storage maximum humidity of 95% is based on a maximum temperature of 45°C (113°F). Altitude maximum for
storage corresponds to a pressure minimum of 70 kPa.
Server specifications
Specification Value
Height
4.32 cm (1.70 in)
Depth
69.53 cm (27.38 in)
Width
42.62 cm (16.78 in)
Weight (maximum: two
processors, two power supplies,
eight hard drives)
15.97 kg (35.20 lb)
Weight (minimum: one processor,
one power supply, no hard drives)
14.51 kg (32.00 lb)
Weight (no drives installed)
14.06 kg (31.00 lb)
Power supply specifications
Depending on installed options, the server is configured with one of the following power supplies:
HP 460 W CS HE Power Supply (92%) specifications (on page 111)
HP 460 W CS Platinum Power Supply (94%) specifications (on page 111)
HP 750 W CS HE Power Supply (92%) specifications (on page 111)
HP 750 W CS Platinum Power Supply (94%) specifications (on page 112)
HP 1200 W CS HE Power Supply (90%) specifications (on page 112)