Operations 23
Install the PCI riser cage
1. Install the PCI riser cage.
2. Install the access panel (on page 22).
3. Install the server into the rack.
4. Power up the server (on page 20).
Remove the air baffle
CAUTION: For proper cooling do not operate the server without the access panel, baffles,
expansion slot covers, or blanks installed. If the server supports hot-plug components, minimize
the amount of time the access panel is open.
1. Power down the server (on page 20).
2. Extend or remove the server from the rack ("Extend the server from the rack" on page 20).
3. Remove the access panel (on page 21).
4. Remove the PCI riser cage (on page 22).
CAUTION: Do not detach the cable that connects the battery pack to the cache module.
Detaching the cable causes any unsaved data in the cache module to be lost.
5. Remove the battery pack from the air baffle.