Hp ProLiant DL385p Gen8 Server Manuel d'utilisateur Page 14

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 135
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 13
Component identification 14
Rear panel LEDs and buttons
Item Description Status
1
UID LED/button Off = Deactivated
Solid blue = Activated
Flashing blue = System being managed remotely
2
Power supply 2
LED
Off = System is off or power supply has failed.
Solid green = Normal
3
Power supply 1
LED
Off = System is off or power supply has failed.
Solid green = Normal
4
NIC activity LED Off = No network activity
Solid green = Link to network
Flashing green = Network activity
5
NIC link LED
Off = No network link
Green = Network link
Non-hot-plug PCIe riser board slot definitions
Primary
Slot - form factor
PCIe 2 riser slot description Secondary
Slot - form factor
PCIe 2 x16 riser slot description
1 - FL/FH
PCIe2 x16 (8,4,1) 4 - FL/FH PCIe2 x16 (16, 8, 4, 1)
2 - HL/FH
PCIe2 x8 (8,4,1) 5 - HL/FH PCIe2 x16 (8, 4, 1)
3 - HL/FH
PCIe2 x8 (4,1)
6 - HL/FH
PCIe2 x8 (8, 4, 1)
Notes:
"Primary" denotes the riser cage is installed in the primary riser connector.
"Secondary" denotes the riser cage is installed in the secondary riser connector.
Installing the riser cages listed in the table above in either the primary or secondary riser connectors
determines the form factor of the PCI cards supported by those riser cages.
FL/FH denotes full-length, full-height. HL/FH denotes half-length, full-height. LP denotes low profile.
Vue de la page 13
1 2 ... 9 10 11 12 13 14 15 16 17 18 19 ... 134 135

Commentaires sur ces manuels

Pas de commentaire