Hp ProLiant DL580 G3 Server Manuel d'utilisateur Page 105

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 190
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 104
Memory options 105
Removing a memory board blank
To remove the memory board blank, squeeze the levers and pull the blank out of
the server.
Removing and installing a memory board while the server is
running
Memory boards can be installed while the server is running in the following
scenarios:
Memory boards can be hot-added if the server is configured for Advanced
ECC and hot-add is enabled in RBSU.
Memory boards can be hot-replaced if the server is configured for hot-plug
mirrored memory or hot-plug RAID memory.
IMPORTANT: Be sure to power down the server when performing
board removal procedures in a server that is not configured for
Advanced ECC, hot-plug mirrored memory, or hot-plug RAID memory.
1. Unlock the locking switch, and open the release latch.
CAUTION: Only memory boards with a green Removable LED can
be removed. Do not attempt to remove any memory board with the
Removable LED off.
Vue de la page 104
1 2 ... 100 101 102 103 104 105 106 107 108 109 110 ... 189 190

Commentaires sur ces manuels

Pas de commentaire