Hp ProLiant DL760 Server Manuel d'utilisateur Page 135

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 229
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 134
5-32 Compaq ProLiant DL760 Servers User Guide
Compaq Confidential Need to Know Required
Writer: Bryce Miller Project: Compaq ProLiant DL760 Servers User Guide Comments:
Part Number: 173774-001 File Name: f-ch5 Installing Hardware Options - Hot Pluggable.doc Last Saved On: 1/18/01 6:12 PM
To replace the hot-plug fan:
1. Open the top access panel.
2. Press the locking latch in and lift the failed hot-plug fan (either 1
or 2) out of the I/O module
.
1
2
Figure 5-18. Removing hot-plug I/O Fan 2
3. Lower the new hot-plug fan into the I/O module until it rests on the I/O
board connector
, holding the locking latch . Push the fan into the
connector and release the locking latch to engage the fan.
1
2
Figure 5-19. Installing a new hot-plug fan 1
4. Verify that the fan is producing airflow and that the LED indicator is
green and close the top access panel.